ABB 1SFL467001R3311 – AF146-30-11-33 Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AF Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 1.55 kg |
| UPC / EAN | 7320500481066 |
Shipping & availability
When can 1SFL467001R3311 be shipped?
1SFL467001R3311 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SFL467001R3311 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SFL467001R3311 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SFL467001R3311, subject to availability and destination.
The AF146-30-11-33 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and double clamp, controlling motors up to 75 kW / 400 V AC (AC-3) or 100 hp / 480 V UL and switching power circuits up to 225 A (AC-1) or 200 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SFL467001R3311 |
| Type | AF146-30-11-33 |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 90 mm |
| Product Net Depth / Length | 142.5 mm |
| Product Net Height | 150 mm |
| Product Net Weight | 1.55 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 225 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (1000 V) 40 °C 225 A, (1000 V) 60 °C 200 A, (1000 V) 70 °C 175 A, (690 V) 40 °C 225 A, (690 V) 60 °C 200 A, (690 V) 70 °C 175 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 60 °C 146 A, (440 V) 60 °C 130 A, (500 V) 60 °C 130 A, (690 V) 60 °C 93 A, (1000 V) 60 °C 60 A, (380 / 400 V) 60 °C 146 A, (220 / 230 / 240 V) 60 °C 146 A |
| Rated Operational Current AC-3e (I<sub>e</sub>) | (415 V) 60 °C 146 A, (440 V) 60 °C 146 A, (500 V) 60 °C 130 A, (690 V) 60 °C 93 A, (380 / 400 V) 60 °C 146 A, (220 / 230 / 240 V) 60 °C 146 A |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 75 kW, (440 V) 90 kW, (500 V) 90 kW, (690 V) 90 kW, (1000 V) 75 kW, (380 / 400 V) 75 kW, (220 / 230 / 240 V) 45 kW |
| Rated Operational Power AC-3e (P<sub>e</sub>) | (415 V) 75 kW, (440 V) 90 kW, (500 V) 90 kW, (690 V) 90 kW, (1000 V) 75 kW, (380 / 400 V) 75 kW, (220 / 230 / 240 V) 45 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Breaking Capacity AC-3e | 8.5 x Ie AC-3e |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Rated Making Capacity AC-3e | 12 x Ie AC-3e |
| Short-Circuit Protective Devices | gG Type Fuses 315 A |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 1000 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour, (AC-2 / AC-4) 150 cycles per hour, (AC-3) 300 cycles per hour |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 100 ... 250 V, 60 Hz 100 ... 250 V, DC Operation 100 ... 250 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 32.2 V·A, Holding at Max. Rated Control Circuit Voltage 50 Hz 2.8 W, Holding at Max. Rated Control Circuit Voltage 60 Hz 32.2 V·A, Holding at Max. Rated Control Circuit Voltage 60 Hz 2.8 W, Holding at Max. Rated Control Circuit Voltage DC 2.9 W, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 242 V·A, Pull-in at Max. Rated Control Circuit Voltage 60 Hz 242 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 289 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 289 W |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 6 W, at Rated Operating Conditions AC-3 per Pole 3 W |
| Operate Time | Between Coil De-energization and NO Contact Opening 37 ... 47 ms, Between Coil Energization and NO Contact Closing 25 ... 55 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 |
| Terminal Type | Double Clamp |
| Product Name | Block Contactor |
Technical UL/CSA
| Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
| General Use Rating UL/CSA | (1000 V AC) 200 A, (600 V AC) 200 A |
| Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 15 Hp, (200 V AC) Three Phase 40 hp, (208 V AC) Three Phase 40 hp, (220 ... 240 V AC) Three Phase 20 Hp, (220 ... 240 V AC) Three Phase 50, (440 ... 480 V AC) Three Phase 40 Hp, (440 ... 480 V AC) Three Phase 100 hp, (550 ... 600 V AC) Three Phase 50 Hp, (550 ... 600 V AC) Three Phase 125 hp |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C, Close to Contactor for Storage -40 ... 70 °C |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
ABB EcoSolutions
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility, UL 2799 Zero Waste To Landfill Validation available |
| Improved Energy Efficiency for Customers | Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line, Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 87.8 % |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4758 >> Iec Contactors |
| E-Number (Finland) | 3707491 |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (12)
More ABB parts
Available on requestAF146-30-00-32 Contactor
Available on requestAF146-30-11-32 Contactor
Available on requestAF146-30-22-32 Contactor
Available on requestAF146-30-00-33 Contactor
Available on requestAF146-30-22-33 Contactor
Available on requestAF146-30-00-34 Contactor
Available on requestAF146-30-11-34 Contactor
Available on requestAF146-30-22-34 Contactor