ABB 1SFL457001R7022 – AF110-30-22 100-250V 50/60Hz / DC Contactor
Discontinued by ABB — we can still source the original 1SFL457001R7022 (new, used or refurbished, subject to availability). Request a quote below.
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AF Contactors |
| Lifecycle | End of life |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 1.9 kg |
| Country of origin | Sweden |
| UPC / EAN | 7320500239704 |
Shipping & availability
Can I still buy the 1SFL457001R7022 now that it is discontinued?
Yes. ABB has discontinued the 1SFL457001R7022, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.
When can 1SFL457001R7022 be shipped?
1SFL457001R7022 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SFL457001R7022 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SFL457001R7022 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SFL457001R7022, subject to availability and destination.
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 100-250 V, AC/DC
Lifecycle: ABB sales units no longer offer this product (end of life). PartnerPLC sources discontinued ABB parts — request a quote for availability, or ask us about the current ABB successor.
Specifications
General
| Order code (ABB product ID) | 1SFL457001R7022 |
| Type | AF110-30-22-70 |
| Lifecycle | End of life (no longer sold by ABB sales units) |
| Country of origin | Sweden |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Replacement Product ID (NEW) | 1SFL427001R1322 |
Dimensions
| Product Net Width | 90 mm |
| Product Net Depth / Length | 156.5 mm |
| Product Net Height | 148 mm |
| Product Net Weight | 1.9 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 2 |
| Number of Auxiliary Contacts NC | 2 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (690 V) 40 °C 160 A, (690 V) 55 °C 145 A, (690 V) 70 °C 130 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 110 A, (440 V) 55 °C 100 A, (500 V) 55 °C 100 A, (690 V) 55 °C 82 A, (1000 V) 55 °C 30 A, (380 / 400 V) 55 °C 110 A, (220 / 230 / 240 V) 55 °C 110 |
| Rated Operational Current DC-1 (I<sub>e</sub>) | (110 V) 2 Poles in Series, 40 °C 160 A, (220 V) 3 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-3 (I<sub>e</sub>) | (110 V) 2 Poles in Series, 40 °C 160 A, (220 V) 3 Poles in Series, 40 °C 160 A |
| Rated Operational Current DC-5 (I<sub>e</sub>) | (110 V) 2 Poles in Series, 40 °C 160 A, (220 V) 3 Poles in Series, 40 °C 160 A |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 59 kW, (440 V) 59 kW, (500 V) 59 kW, (690 V) 75 kW, (1000 V) 40 kW, (380 / 400 V) 55 kW, (220 / 230 / 240 V) 30 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Short-Circuit Protective Devices | gG Type Fuses 160 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour, (AC-2 / AC-4) 150 cycles per hour, (AC-3) 300 cycles per hour |
| Mechanical Durability | 10 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 48 ... 130 V, 60 Hz 48 ... 130 V, DC Operation 48 ... 130 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A, Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A, Holding at Max. Rated Control Circuit Voltage DC 2 W, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A, Pull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 400 W |
| Power Loss | at Rated Operating Conditions per Pole 3.5 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 60 ... 130 ms, Between Coil De-energization and NO Contact Opening 55 ... 125 ms, Between Coil Energization and NC Contact Opening 27 ... 77 ms, Between Coil Energization and NO Contact Closing 30 ... 80 ms |
| Connecting Capacity Main Circuit | Bar 30 mm², Flexible with Cable End 1 x 10 ... 70 mm², Rigid 1 x 10 ... 95 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible 2x0.75 ... 2.5 mm², Solid 2 x 1 ... 4 mm², Stranded 2 x 1 .... 4 mm² |
| Connecting Capacity | Bar 30 mm², Flexible with Cable End 1 x 10 ... 70 mm², Rigid 2 x 6 ... 65 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| Connecting Terminals (delivered in open position) Main Poles | M8 hexagon socket screw with single connector |
| Tightening Torque | Main Circuit 8 N·m |
| Terminal Type | Cable Clamp |
| Product Name | Block Contactor |
Technical UL/CSA
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 140 A |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 30 hp, (208 V AC) Three Phase 30 hp, (220 ... 240 V AC) Three Phase 40, (440 ... 480 V AC) Three Phase 75 hp, (550 ... 600 V AC) Three Phase 100 hp |
| Full Load Amps Motor Use | (440 ... 480 V AC) Three Phase 96 A, (550 ... 600 V AC) Three Phase 99 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g, Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100192C0206) | |
| Instructions and Manuals (5309660-60) | |
| Dimension Diagram (53540923-6) |
Certificates (10)
More ABB parts
Available on requestAF110-30-11 48-130V 50/60Hz / DC Contactor
Available on requestAF110-30-22 48-130V 50/60Hz / DC Contactor
Available on requestAF110-30-00 100-250V 50/60Hz / DC Contactor
Available on requestAF110-30-11 100-250V 50/60Hz / DC Contactor
Available on requestAF110-30-00 20-60V DC Contactor
Available on requestAF110-30-11 20-60V DC Contactor
Available on requestAF110-30-22 20-60V DC Contactor
Available on requestAF110-30-11RT 100-250V Contactor