| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 2 |
| Number of Auxiliary Contacts NC | 2 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22 |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 1000 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Control Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (1000 V) 60 °C 105 A, (690 V) 40 °C 130 A, (690 V) 70 °C 90 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 60 °C 105 A, (440 V) 60 °C 105 A, (500 V) 60 °C 80 A, (690 V) 60 °C 57 A, (1000 V) 60 °C 30 A, (380 / 400 V) 60 °C 105 A, (220 / 230 / 240 V) 60 °C 105 A |
| Rated Operational Current AC-3e (I<sub>e</sub>) | (415 V) 60 °C 96 A, (440 V) 60 °C 96 A, (500 V) 60 °C 80 A, (690 V) 60 °C 57 A, (380 / 400 V) 60 °C 105 A, (220 / 230 / 240 V) 60 °C 105 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (400 / 440 V) 3 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (125 V) 0.55 A / 69 W, (220 V) 0.27 A / 60 W, (250 V) 0.27 A / 68 W, (400 V) 0.15 A / 60 W, (500 V) 0.13 A / 65 W, (600 V) 0.1 A / 60 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 55 kW, (440 V) 55 kW, (500 V) 55 kW, (690 V) 55 kW, (1000 V) 40 kW, (380 / 400 V) 45 kW, (380 / 400 V) 55 kW, (220 / 230 / 240 V) 25 kW, (220 / 230 / 240 V) 30 kW |
| Rated Operational Power AC-3e (P<sub>e</sub>) | (415 V) 55 kW, (440 V) 55 kW, (500 V) 55 kW, (690 V) 55 kW, (380 / 400 V) 45 kW, (380 / 400 V) 55 kW, (220 / 230 / 240 V) 25 kW, (220 / 230 / 240 V) 30 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A, for 0.1 s 140 A, for 1 s 100 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 1000 V, acc. to IEC 60947-5-1 690 V, acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | 8 kV |
| Maximum Electrical Switching Frequency | (AC-15) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 250 ... 500 V, 60 Hz 250 ... 500 V, DC Operation 250 ... 500 V |
| Power Loss | at 6 A per Pole 0.1 W, at Rated Operating Conditions AC-1 per Pole 8.2 W, at Rated Operating Conditions AC-3 per Pole 4.5 W |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) | 2 x M4 or 2 x M6 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 6 ... 50 mm², Flexible with Insulated Ferrule 1/2x 6 ... 50 mm², Rigid Stranded 1x 6 ... 70 mm², Rigid Stranded 2x 6 ... 50 mm² |
| Wire Stripping Length | Auxiliary Circuit 10 mm, Control Circuit 10 mm, Main Circuit 17 mm |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| Tightening Torque | Auxiliary Circuit 1.2 N·m, Control Circuit 1.2 N·m, Main Circuit 6 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Contactor Starter |