ABB 1SBL931074R8801 – AX25-30-01-88 230-240V50Hz/240V-260V60Hz Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.326 kg |
| UPC / EAN | 3471522398888 |
Shipping & availability
When can 1SBL931074R8801 be shipped?
1SBL931074R8801 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL931074R8801 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL931074R8801 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL931074R8801, subject to availability and destination.
AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL931074R8801 |
| Type | AX25-30-01-88 |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 44 mm |
| Product Net Depth / Length | 74 mm |
| Product Net Height | 76.3 mm |
| Product Net Weight | 0.326 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 32 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 27 A, (690 V) 40 °C 32 A, (690 V) 70 °C 23 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 25 A, (440 V) 55 °C 16 A, (500 V) 55 °C 14 A, (690 V) 55 °C 10 A, (380 / 400 V) 55 °C 25 A, (220 / 230 / 240 V) 55 °C 25 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A, (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (110 V) 1.1 A / 121 W, (125 V) 1.1 A / 138 W, (220 V) 0.55 A / 121 W, (250 V) 0.55 A / 138 W, (400 V) 2.8 A / 134 W, (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 11 kW, (440 V) 9 kW, (500 V) 9 kW, (690 V) 9 kW, (380 / 400 V) 11 kW, (220 / 230 / 240 V) 6.5 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 230 ... 240 V, 60 Hz 240 ... 260 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 12 V·A, Average Holding Value 50 Hz 12 V·A, Average Holding Value 60 Hz 12 V·A, Average Holding Value, from Warm State 3 W, Average Pull-in Value 50 Hz 120 V·A, Average Pull-in Value 60 Hz 140 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1.2 W, at Rated Operating Conditions AC-3 per Pole 0.35 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 9 ... 16 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 7 ... 21 ms, Between Coil Energization and NO Contact Closing 10 ... 26 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m, Control Circuit 1 N·m, Main Circuit 1.2 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 30 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 2 hp, (200 ... 208 V AC) Three Phase 7.5 hp, (220 ... 240 V AC) Three Phase 7.5, (240 V AC) Single Phase 3 hp, (440 ... 480 V AC) Three Phase 15 hp, (550 ... 600 V AC) Three Phase 15 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 11 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 24 A, (200 ... 208 V AC) Three Phase 25.3 A, (220 ... 240 V AC) Three Phase 22 A, (240 V AC) Single Phase 17 A, (440 ... 480 V AC) Three Phase 21 A, (550 ... 600 V AC) Three Phase 17 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 9fd3413a-39fc-440d-86b3-abdf6b3bb9b1 Bulgaria |
| Simplified SCIP | 0d25d8b1-5679-43e9-a804-c0dbb237904f Belgium, 1a9caf66-6a3c-4c95-ae50-4c9de2c15581 Belgium, 216dcd9b-1717-4426-a2b1-1a7ef4cc21a9 Netherlands, 29b9bf96-db65-4d1a-a2e6-89fa52f33546 Croatia, 3a0c4bc5-3a10-4b8d-9ee7-1b9740a9d44f Estonia, 3f7bee5b-c278-4c1d-842e-666c9bc18286 Spain, 5280b483-1f56-4d9c-95a9-8beb3397d5ff Hungary, 5969c4ba-2b0b-41cf-a0ff-ca3cc0c4f5f7 Poland, 5d24e706-42c5-4888-8cf0-99aa37dbe16b Norway, 61c519c2-922b-443c-8cff-0e44539c89bb Sweden, 623cf637-0a3a-48e3-ba00-988caac68076 Denmark, 65481452-f6e6-465a-932b-ad1038226c56 Germany, 6d201252-69bb-48ba-af67-ed28bf953e2a Germany, 76de33ee-9840-4f65-9248-0537beabfce3 Germany, 7a377a79-2fa1-4852-965f-56920f1bf350 Portugal, 7f9917ab-6e1c-4505-9b6b-bd311249c158 Finland, 8a269d36-0055-43c8-a80c-a74d1462e7a1 Hungary, a4cad139-2171-4aa9-a57f-74b6a5e72ca4 France, b6f4a4c3-21e4-43f4-b32a-73b961798d4e Italy, c83d2754-3492-41de-aed3-02da8ad9953b Poland, c870ac8f-666a-45ec-ac40-ddd3913769bf Czechia, cb498fec-3c51-45e5-a3cb-60e48495d5d3 Greece, cdf6abe0-d431-46af-979e-11659b0b7bd8 Germany, d4cc5f15-c5a4-46f1-9569-ecb5ad579eea Sweden, d5fd629c-6184-4f82-93f3-368541a8fc65 Poland, ee7332c8-c523-42d7-bb64-1129c4799af6 Germany, fdea76bf-bddf-4f6e-8ec1-7e2b4e390eff France |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7057) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX25-30-01-85 380-400V50Hz/400V-415V60Hz Contactor
Available on requestAX25-30-10-85 380-400V50Hz/400V-415V60Hz Contactor
Available on requestAX25-30-01-86 400-415V50Hz/415V-440V60Hz Contactor
Available on requestAX25-30-10-86 400-415V50Hz/415V-440V60Hz Contactor
Available on requestAX25-30-10-88 230-240V50Hz/240V-260V60Hz Contactor
Available on requestA2X25-30-01 110V50HZ/60HZ Contactor with 40Pcs
Available on requestA2X25-30-10 110V50HZ/60HZ Contactor with 40Pcs
Available on requestA2X25-30-01 220V50HZ/230V60HZ Contactor with 40Pcs