ABB 1SBL921074R8410 – AX18-30-10-84 110V50Hz/110-120V60Hz Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.326 kg |
| Country of origin | India |
| UPC / EAN | 3471522395849 |
Shipping & availability
When can 1SBL921074R8410 be shipped?
1SBL921074R8410 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL921074R8410 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL921074R8410 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL921074R8410, subject to availability and destination.
AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL921074R8410 |
| Type | AX18-30-10-84 |
| Lifecycle | Active (current ABB product) |
| Country of origin | India |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 44 mm |
| Product Net Depth / Length | 74 mm |
| Product Net Height | 74 mm |
| Product Net Weight | 0.326 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 28 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 25 A, (690 V) 40 °C 27 A, (690 V) 70 °C 20 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 18 A, (440 V) 55 °C 12 A, (500 V) 55 °C 12 A, (690 V) 55 °C 9 A, (380 / 400 V) 55 °C 18 A, (220 / 230 / 240 V) 55 °C 18 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A, (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (110 V) 1.1 A / 121 W, (125 V) 1.1 A / 138 W, (220 V) 0.55 A / 121 W, (250 V) 0.55 A / 138 W, (400 V) 2.8 A / 134 W, (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 9 kW, (440 V) 5.5 kW, (500 V) 7.5 kW, (690 V) 7.5 kW, (380 / 400 V) 7.5 kW, (220 / 230 / 240 V) 4 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 145 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 28 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 110 V, 60 Hz 110 ... 120 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 8 V·A, Average Holding Value 50 Hz 8 V·A, Average Holding Value 60 Hz 8 V·A, Average Holding Value, from Warm State 2 W, Average Pull-in Value 50 Hz 70 V·A, Average Pull-in Value 60 Hz 80 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1 W, at Rated Operating Conditions AC-3 per Pole 0.2 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 9 ... 16 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 7 ... 21 ms, Between Coil Energization and NO Contact Closing 10 ... 26 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m, Control Circuit 1 N·m, Main Circuit 1 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 30 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 1 hp, (200 ... 208 V AC) Three Phase 5 hp, (220 ... 240 V AC) Three Phase 5, (240 V AC) Single Phase 3 hp, (440 ... 480 V AC) Three Phase 10 hp, (550 ... 600 V AC) Three Phase 15 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 9 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 16 A, (200 ... 208 V AC) Three Phase 17.5 A, (220 ... 240 V AC) Three Phase 15.2 A, (240 V AC) Single Phase 17 A, (440 ... 480 V AC) Three Phase 14 A, (550 ... 600 V AC) Three Phase 17 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 43498e3d-1c30-45aa-be27-1e63a860446b Bulgaria |
| Simplified SCIP | 07aec1c5-7f0e-49bd-a4ea-e7bc957b73e1 Germany, 09adc6a8-a908-455f-a62b-641f9beae35d Germany, 20eb113c-6420-4d45-9209-174b71fdfd8a Sweden, 2a89622a-8e2e-436c-a3f6-3f0563292458 Norway, 377a862e-d0ec-4020-9c9c-bb7b2722cc72 Sweden, 465c5d83-8701-4786-b1ad-668176df3822 Czechia, 498ed896-2946-4b30-bf49-0055704ef3cb Poland, 519fd703-8659-4565-8cac-9e6512a10e54 Finland, 572a201c-0569-424f-a112-321876df8a94 Portugal, 5f6b164d-be06-411c-8da3-dbc0c791590a France, 6162269b-1832-44dc-8a66-9e6227f61a0d Netherlands, 67282408-84d2-4de4-bcae-c2715a8e91f7 France, 7818fe63-35f7-4c3b-b4ae-66b3c0e7b45c Italy, 8981f8b1-c33f-4273-aeda-2fecbea545bc Belgium, 89ab4d6c-64f5-49f8-b25d-ce865eca9ec4 Hungary, a0396816-5754-4db1-9f76-d8904dba71f1 Germany, a082eee9-8307-4189-b4fa-5e94874e836a Hungary, a74497d5-6942-4f35-ba0e-83e5ef840f7f Spain, a8920997-8f22-41f4-8a4e-f825d86d3ba5 Belgium, ade0dad8-39cd-4cbb-b6e9-696d3b482304 Croatia, baa4be71-898d-4501-8490-15caee4aeb30 Germany, bceacf68-2f36-48e6-bea2-85a7adb16409 Denmark, c4a8b93f-c160-4e10-9834-bda7984bc52e Poland, c96be507-a7f5-472b-ae54-74286a1912d6 Greece, d195449c-ba62-4fec-bb4f-dcf2f8b49ec2 Poland, e791efe4-8534-48cb-8d30-20d6f8c3c288 Germany, e8e7036d-a0bd-4724-a1f0-b07c067a0ac8 Estonia |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
| E-Number (Finland) | 3707328 |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7057) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX18-30-10-81 24V 50/60Hz Contactor
Available on requestAX18-30-01-83 48V 50/60Hz Contactor
Available on requestAX18-30-10-83 48V 50/60Hz Contactor
Available on requestAX18-30-01-84 110V50Hz/110-120V60Hz Contactor
Available on requestAX18-30-01-85 380-400V50Hz/400V-415V60Hz Contactor
Available on requestAX18-30-10-85 380-400V50Hz/400V-415V60Hz Contactor
Available on requestAX18-30-01-86 400-415V50Hz/415V-440V60Hz Contactor
Available on requestAX18-30-10-86 400-415V50Hz/415V-440V60Hz Contactor