ABB 1SBL921074R8010 – AX18-30-10-80 220-230V50Hz/230-240V60Hz Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.326 kg |
| Country of origin | India |
| UPC / EAN | 3471522395801 |
Shipping & availability
When can 1SBL921074R8010 be shipped?
1SBL921074R8010 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL921074R8010 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL921074R8010 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL921074R8010, subject to availability and destination.
AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL921074R8010 |
| Type | AX18-30-10-80 |
| Lifecycle | Active (current ABB product) |
| Country of origin | India |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 44 mm |
| Product Net Depth / Length | 74 mm |
| Product Net Height | 74 mm |
| Product Net Weight | 0.326 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 28 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 25 A, (690 V) 40 °C 27 A, (690 V) 70 °C 20 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 18 A, (440 V) 55 °C 12 A, (500 V) 55 °C 12 A, (690 V) 55 °C 9 A, (380 / 400 V) 55 °C 18 A, (220 / 230 / 240 V) 55 °C 18 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A, (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (110 V) 1.1 A / 121 W, (125 V) 1.1 A / 138 W, (220 V) 0.55 A / 121 W, (250 V) 0.55 A / 138 W, (400 V) 2.8 A / 134 W, (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 9 kW, (440 V) 5.5 kW, (500 V) 7.5 kW, (690 V) 7.5 kW, (380 / 400 V) 7.5 kW, (220 / 230 / 240 V) 4 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 145 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 28 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 220 ... 230 V, 60 Hz 230 ... 240 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 8 V·A, Average Holding Value 50 Hz 8 V·A, Average Holding Value 60 Hz 8 V·A, Average Holding Value, from Warm State 2 W, Average Pull-in Value 50 Hz 70 V·A, Average Pull-in Value 60 Hz 80 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1 W, at Rated Operating Conditions AC-3 per Pole 0.2 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 9 ... 16 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 7 ... 21 ms, Between Coil Energization and NO Contact Closing 10 ... 26 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m, Control Circuit 1 N·m, Main Circuit 1 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 30 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 1 hp, (200 ... 208 V AC) Three Phase 5 hp, (220 ... 240 V AC) Three Phase 5, (240 V AC) Single Phase 3 hp, (440 ... 480 V AC) Three Phase 10 hp, (550 ... 600 V AC) Three Phase 15 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 9 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 16 A, (200 ... 208 V AC) Three Phase 17.5 A, (220 ... 240 V AC) Three Phase 15.2 A, (240 V AC) Single Phase 17 A, (440 ... 480 V AC) Three Phase 14 A, (550 ... 600 V AC) Three Phase 17 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 04263894-a884-47f8-9d57-8150565d112c Bulgaria |
| Simplified SCIP | 01731298-b2d8-4702-bbcf-ae2a0e2c0da1 France, 0d28b4d9-175f-408c-9f16-e95422cc70f0 Germany, 18cee740-e770-4b8c-8a25-cd0109d52cb0 Sweden, 26fc22df-7bb0-4098-9ce4-f0484ad383ad Hungary, 34eed3a9-3813-4fed-adc2-fd88a02f172a Netherlands, 362c0450-9691-4080-8d08-1edd46644212 Portugal, 3d31ece8-f7cb-40fd-b1f3-6f368379251c Sweden, 3e60a83b-4a3c-465d-9ba9-0957bdfd100d Poland, 4c43fd63-7777-4553-ba19-57628859425d Croatia, 58552496-0908-4e19-a881-d85135d5ae19 Greece, 6f2b09d4-d7ef-4e3a-bad9-11c90f1a4798 Czechia, 7585c89d-583d-469a-a747-4fd0e54e9d7e Germany, 7d91453d-3f33-4831-b601-63397de2a8c2 Finland, 7e180c97-6396-4df8-a59d-6c4d23df92bd Denmark, 7ff1909c-8c58-4f05-a0a8-b2da85fe0a1e Spain, 9ffabfb4-a88a-43ac-a46f-70f60e387aa2 Italy, a666e81d-f5da-401e-abe5-4c6a9d8f49d2 Hungary, a8177241-f617-4436-9e09-184e43dc0bb1 Belgium, bc7edf4f-db1a-4315-8da6-6df026f56d8a France, cf4fc4e7-4315-4bf4-96e1-7aa69551e00b Estonia, d33352b8-116e-4532-ac29-d7f1f208fadd Belgium, d82eccab-f5c9-4989-a810-58757e528715 Norway, dc1c2737-6317-4648-95c1-709167981fab Poland, e36ad6ad-2f2b-4b02-a25f-06664946a6d3 Germany, ebf58b52-c49c-4f48-a3c1-f34a27aafd02 Germany, f112d6cf-9316-45a8-a54f-9df708358fd9 Poland, f8c0f8f2-42ac-4178-8195-0e53de400863 Germany |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
| E-Number (Finland) | 3707326 |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7057) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX18-30-10-36 190V50Hz/220V60Hz Contactor
Available on requestAX18-30-01-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX18-30-10-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX18-30-01-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX18-30-01-81 24V 50/60Hz Contactor
Available on requestAX18-30-10-81 24V 50/60Hz Contactor
Available on requestAX18-30-01-83 48V 50/60Hz Contactor
Available on requestAX18-30-10-83 48V 50/60Hz Contactor