Quick facts
| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.326 kg |
| UPC / EAN | 3471522393883 |
Shipping & availability
When can 1SBL911074R8810 be shipped?
1SBL911074R8810 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL911074R8810 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL911074R8810 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL911074R8810, subject to availability and destination.
AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL911074R8810 |
| Type | AX12-30-10-88 |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 44 mm |
| Product Net Depth / Length | 74 mm |
| Product Net Height | 74 mm |
| Product Net Weight | 0.326 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 26 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 22 A, (690 V) 40 °C 25 A, (690 V) 70 °C 18 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 12 A, (440 V) 55 °C 9 A, (500 V) 55 °C 9 A, (690 V) 55 °C 7 A, (380 / 400 V) 55 °C 12 A, (220 / 230 / 240 V) 55 °C 12 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A, (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (110 V) 1.1 A / 121 W, (125 V) 1.1 A / 138 W, (220 V) 0.55 A / 121 W, (250 V) 0.55 A / 138 W, (400 V) 2.8 A / 134 W, (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 5.5 kW, (440 V) 4 kW, (500 V) 5.5 kW, (690 V) 5.5 kW, (380 / 400 V) 5.5 kW, (220 / 230 / 240 V) 3 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 230 ... 240 V, 60 Hz 240 ... 260 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 8 V·A, Average Holding Value 50 Hz 8 V·A, Average Holding Value 60 Hz 8 V·A, Average Holding Value, from Warm State 2 W, Average Pull-in Value 50 Hz 70 V·A, Average Pull-in Value 60 Hz 80 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 0.8 W, at Rated Operating Conditions AC-3 per Pole 0.1 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 9 ... 16 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 7 ... 21 ms, Between Coil Energization and NO Contact Closing 10 ... 26 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m, Control Circuit 1 N·m, Main Circuit 1 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 25 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 3/4 hp, (200 ... 208 V AC) Three Phase 3 hp, (220 ... 240 V AC) Three Phase 3, (240 V AC) Single Phase 2 hp, (440 ... 480 V AC) Three Phase 7.5 hp, (550 ... 600 V AC) Three Phase 10 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 9 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 13.8 A, (200 ... 208 V AC) Three Phase 11 A, (220 ... 240 V AC) Three Phase 9.6 A, (240 V AC) Single Phase 12 A, (440 ... 480 V AC) Three Phase 11 A, (550 ... 600 V AC) Three Phase 11 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 8b51e104-3fef-4f43-a597-1ee424107e73 Bulgaria |
| Simplified SCIP | 10de99ec-f336-4abc-9264-c9c4dacaf012 Belgium, 39768e3f-3a95-4237-ae3e-d94a606eb5f7 Poland, 4412d317-609f-46d9-adff-d67e5fba5bbb Estonia, 512c0e0c-bf24-4baf-b602-89267a67f72a Italy, 57a3a145-00c2-40ce-a5e6-176d3b8307fa France, 587e21fc-33f3-4a6f-af72-534314e4f5f1 Poland, 5e867107-dce0-4cf9-8b99-38ae2b2580de Netherlands, 6b46030d-6367-4f3c-aa17-d5004496a32a Sweden, 74edea50-97f8-4bc8-81dd-aa8f5091f8a4 Spain, 7bedb21f-8a46-4b16-b179-d5461a3eb067 Germany, 7e9a8ae0-9f49-4d08-866c-df67ecf422b2 Finland, 7fb2ca86-7a0a-4849-a367-751afe677b3e Denmark, 80abdcba-95b8-4a24-8e7c-d9875ba11d98 Croatia, 8d60eea3-f102-4637-99de-10f2de1154d5 Germany, 9225070f-2973-4e53-aad4-04c976da03a3 France, 94567586-f8b1-4652-99d9-4f4c38cbd1da Germany, 9b8abfcf-afe2-4736-85de-5a7894b70fe2 Germany, a0ceb761-f54e-4b62-87a2-f6adc22158a8 Germany, a8c83614-57a9-4de5-a3d9-02050b9d77d3 Hungary, a9a4bff5-07cc-4fba-86cb-79a1ab074d6d Norway, a9ee17ff-2fdd-4a54-925f-2258b3335323 Hungary, bd64800c-ba3c-4aa0-8ab9-c3de9569bb49 Poland, be73a75d-cd3f-4e42-bcfe-5f909a5bf8ee Sweden, c9c65cee-dc5d-44e3-b4fa-82a57f541a3e Portugal, d3dc9adf-1c6e-43f4-aa03-f9c460434afc Greece, dd4a51cb-3a38-4d8a-8024-7661cbdec437 Belgium, df08df7b-16ff-4ddf-bdf7-a6f49fddd77a Czechia |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7057) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX12-30-10-85 380-400V50Hz/400V-415V60Hz Contactor
Available on requestAX12-30-01-86 400-415V50Hz/415V-440V60Hz Contactor
Available on requestAX12-30-10-86 400-415V50Hz/415V-440V60Hz Contactor
Available on requestAX12-30-01-88 230-240V50Hz/240V-260V60Hz Contactor
Available on requestA2X12-30-01 110V50HZ/60HZ Contactor with 40Pcs
Available on requestA2X12-30-10 110V50HZ/60HZ Contactor with 40Pcs
Available on requestA2X12-30-01 220V50HZ/230V60HZ Contactor with 40Pcs
Available on requestA2X12-30-10 220V50HZ/230V60HZ Contactor with 40Pcs