ABB 1SBL901074R8810 – AX09-30-10-88 230-240V50Hz/240V-260V60Hz Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.326 kg |
| UPC / EAN | 3471522391889 |
Shipping & availability
When can 1SBL901074R8810 be shipped?
1SBL901074R8810 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL901074R8810 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL901074R8810 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL901074R8810, subject to availability and destination.
AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL901074R8810 |
| Type | AX09-30-10-88 |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 44 mm |
| Product Net Depth / Length | 74 mm |
| Product Net Height | 74 mm |
| Product Net Weight | 0.326 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 24 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 22 A, (690 V) 40 °C 22 A, (690 V) 70 °C 18 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 9 A, (440 V) 55 °C 9 A, (500 V) 55 °C 9 A, (690 V) 55 °C 7 A, (380 / 400 V) 55 °C 9 A, (220 / 230 / 240 V) 55 °C 9 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A, (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (110 V) 1.1 A / 121 W, (125 V) 1.1 A / 138 W, (220 V) 0.55 A / 121 W, (250 V) 0.55 A / 138 W, (400 V) 2.8 A / 134 W, (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 4 kW, (440 V) 4 kW, (500 V) 5.5 kW, (690 V) 5.5 kW, (380 / 400 V) 4 kW, (220 / 230 / 240 V) 2.2 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 50 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 60 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 230 ... 240 V, 60 Hz 240 ... 260 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 8 V·A, Average Holding Value 50 Hz 8 V·A, Average Holding Value 60 Hz 8 V·A, Average Holding Value, from Warm State 2 W, Average Pull-in Value 50 Hz 70 V·A, Average Pull-in Value 60 Hz 80 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 0.8 W, at Rated Operating Conditions AC-3 per Pole 0.1 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 9 ... 16 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 7 ... 21 ms, Between Coil Energization and NO Contact Closing 10 ... 26 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m, Control Circuit 1 N·m, Main Circuit 1 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 21 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 1/2 hp, (200 ... 208 V AC) Three Phase 2 hp, (220 ... 240 V AC) Three Phase 2, (240 V AC) Single Phase 1.5 hp, (440 ... 480 V AC) Three Phase 5 hp, (550 ... 600 V AC) Three Phase 7.5 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 9 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 9.8 A, (200 ... 208 V AC) Three Phase 7.8 A, (220 ... 240 V AC) Three Phase 6.8 A, (240 V AC) Single Phase 10 A, (440 ... 480 V AC) Three Phase 7.6 A, (550 ... 600 V AC) Three Phase 9 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 0f68e0fb-5afb-4626-88c8-dd65e89e514b Bulgaria |
| Simplified SCIP | 1c159827-a3ca-4979-ba82-2129b2485c8e France, 22e055fb-a64b-4610-95c5-e523563aa2d3 Sweden, 378442dc-acc9-4fd8-b0e8-9324342563eb Sweden, 4c39dc40-d4b4-49b1-ad78-435d260da4b9 Poland, 5273f814-9076-4b79-a822-3388a31c98c3 Poland, 5fb9e463-2b06-4396-a2d9-93423b8a18c9 Hungary, 6e12609a-2f2d-4995-a13a-4e51776afdb4 Germany, 7d268ecf-fd97-468d-9d6d-c99727dd40b0 Czechia, 7d75528c-92cd-49e5-8349-0ef798d72dbe Belgium, 81fb906b-a750-40ec-b9b1-bc51e6b77949 Norway, 821fa5c4-24ef-41e7-af45-787d1d4e2c55 Hungary, 9371c305-d2f8-4e12-98c3-7a96c7e3a254 Denmark, b3082d7c-d2d1-45cb-9423-2499d00b23ff Italy, c2587eaf-545c-4608-bed7-ff6f47512712 Netherlands, c31b287f-012a-4ace-acbd-d7a1f72b0d16 Estonia, cd00ffdc-6622-45b4-abef-8dc3349321da Germany, cda56c86-f4ab-49d3-92c2-2af98876adcc Greece, d45e8216-5934-4032-9eb6-773e920ba9c2 Finland, d5203c6c-dc30-42af-9950-e06121db44ff Germany, e2275ed8-21c0-4ce6-8f68-15a787563bb4 Spain, e993554a-cd10-44b4-b895-128d13a08f4d Poland, ee74fdbf-e175-418a-ba13-9c3bbb7d3a9c Germany, ef56780a-3cb0-48bd-9700-efc51fd28ac6 Portugal, f24d4208-3aa7-4e04-8005-9d70b0424889 Germany, f93bb4f6-38ec-47f5-a5a5-5955c31a7c2c Belgium, fb3902b2-3ca7-4b58-af3a-611c37f33252 France, ffb85e84-aa85-470d-8a7b-32703f270122 Croatia |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7057) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX09-30-10-85 380-400V50Hz/400V-415V60Hz Contactor
Available on requestAX09-30-01-86 400-415V50Hz/415V-440V60Hz Contactor
Available on requestAX09-30-10-86 400-415V50Hz/415V-440V60Hz Contactor
Available on requestAX09-30-01-88 230-240V50Hz/240V-260V60Hz Contactor
Available on requestA2X09-30-01 110V50HZ/60HZ Contactor with 40Pcs
Available on requestA2X09-30-10 110V50HZ/60HZ Contactor with 40Pcs
Available on requestA2X09-30-01 220V50HZ/230V60HZ Contactor with 40Pcs
Available on requestA2X09-30-10 220V50HZ/230V60HZ Contactor with 40Pcs