ABB 1SBL901074R8101 – AX09-30-01-81 24V 50/60Hz Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.326 kg |
| Country of origin | India |
| UPC / EAN | 3471522392817 |
Shipping & availability
When can 1SBL901074R8101 be shipped?
1SBL901074R8101 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL901074R8101 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL901074R8101 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL901074R8101, subject to availability and destination.
AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL901074R8101 |
| Type | AX09-30-01-81 |
| Lifecycle | Active (current ABB product) |
| Country of origin | India |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 44 mm |
| Product Net Depth / Length | 74 mm |
| Product Net Height | 74 mm |
| Product Net Weight | 0.326 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 24 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 22 A, (690 V) 40 °C 22 A, (690 V) 70 °C 18 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 9 A, (440 V) 55 °C 9 A, (500 V) 55 °C 9 A, (690 V) 55 °C 7 A, (380 / 400 V) 55 °C 9 A, (220 / 230 / 240 V) 55 °C 9 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A, (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (110 V) 1.1 A / 121 W, (125 V) 1.1 A / 138 W, (220 V) 0.55 A / 121 W, (250 V) 0.55 A / 138 W, (400 V) 2.8 A / 134 W, (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 4 kW, (440 V) 4 kW, (500 V) 5.5 kW, (690 V) 5.5 kW, (380 / 400 V) 4 kW, (220 / 230 / 240 V) 2.2 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 50 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 60 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 24 V, 60 Hz 24 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 8 V·A, Average Holding Value 50 Hz 8 V·A, Average Holding Value 60 Hz 8 V·A, Average Holding Value, from Warm State 2 W, Average Pull-in Value 50 Hz 70 V·A, Average Pull-in Value 60 Hz 80 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 0.8 W, at Rated Operating Conditions AC-3 per Pole 0.1 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 9 ... 16 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 7 ... 21 ms, Between Coil Energization and NO Contact Closing 10 ... 26 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m, Control Circuit 1 N·m, Main Circuit 1 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 21 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 1/2 hp, (200 ... 208 V AC) Three Phase 2 hp, (220 ... 240 V AC) Three Phase 2, (240 V AC) Single Phase 1.5 hp, (440 ... 480 V AC) Three Phase 5 hp, (550 ... 600 V AC) Three Phase 7.5 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 9 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 9.8 A, (200 ... 208 V AC) Three Phase 7.8 A, (220 ... 240 V AC) Three Phase 6.8 A, (240 V AC) Single Phase 10 A, (440 ... 480 V AC) Three Phase 7.6 A, (550 ... 600 V AC) Three Phase 9 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | cd7091b2-87c7-48c0-afa9-aefb3a1d9562 Bulgaria |
| Simplified SCIP | 15238f5a-e2e2-49fa-ac33-3d5c8ee69afa Poland, 1af86fec-3a91-4715-8739-a2f4518abcd5 Hungary, 2c7e59d1-a4cd-42c7-a0e6-97d0125cdd8c Belgium, 325825f3-87b5-40f9-b285-fccf701fece4 Sweden, 33296357-33d7-4620-b0ed-7a281e384ee9 France, 47edc02d-1028-4016-906f-6b771fccf6d3 Spain, 5f86647d-f1bf-49fa-ad03-6fa112973c96 Norway, 6455fcfa-b50a-4874-b66b-2b0fc1eb686d Belgium, 654e1a67-1b51-42dd-beba-a577849b005e Denmark, 66399b15-0e9f-40bf-9913-5bcdfb22af89 Germany, 6ce1a5a9-1463-4601-a551-3d7018bfc20b Finland, 6e934650-cee1-481a-8af4-c4cbe0f16981 Croatia, 740b98c3-4818-4792-b57b-80b7916f863d Germany, 765c58d5-903b-46c8-aeab-405db44ea176 Portugal, 7d29b735-ede7-493f-bef1-1e1bf2d0edab Germany, 7e70d687-ade8-404e-a2f1-df718d90fa4b Poland, 8346952c-1906-4f95-9a4f-04140e82c09b Sweden, 9509d235-eeeb-4f29-ad00-0db3d0ed7b55 Germany, a21df17d-837c-4491-be1c-4dbfa825a413 Hungary, a35528ce-6273-4038-81bb-6daa1e97f51d Poland, aa5f1448-bc6a-4e2e-9262-ee2dd5eb686e Estonia, ad2c1748-8716-45bf-9393-b292bab01bc2 Netherlands, b2cd0544-1c24-4867-9265-976b94c7051e France, b2eb9fe0-1c0d-4a16-9b4d-f7e0a27449c2 Czechia, d8c6f183-3748-4233-9da3-8a9d4f8faa9c Germany, db374f31-cf36-4747-997a-0a81cbb4b39b Italy, fc3d047f-c06f-456d-be01-1d2498a3e0ff Greece |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
| E-Number (Finland) | 3707299 |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7057) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX09-30-01-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX09-30-10-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX09-30-01-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX09-30-10-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX09-30-10-81 24V 50/60Hz Contactor
Available on requestAX09-30-01-83 48V 50/60Hz Contactor
Available on requestAX09-30-10-83 48V 50/60Hz Contactor
Available on requestAX09-30-01-84 110V50Hz/110-120V60Hz Contactor