| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, UL 60335-2-40 LZGH2 A2L |
| Rated Operational Voltage | Main Circuit 1000 V |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (690 V) 40 °C 130 A, (690 V) 60 °C 105 A, (690 V) 70 °C 90 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 60 °C 96 A, (440 V) 60 °C 96 A, (500 V) 60 °C 80 A, (690 V) 60 °C 57 A, (1000 V) 60 °C 30 A, (380 / 400 V) 60 °C 96 A, (220 / 230 / 240 V) 60 °C 96 A |
| Rated Operational Current AC-3e (I<sub>e</sub>) | (415 V) 60 °C 96 A, (440 V) 60 °C 96 A, (500 V) 60 °C 80 A, (690 V) 60 °C 57 A, (380 / 400 V) 60 °C 96 A, (220 / 230 / 240 V) 60 °C 96 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2 |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (125 V) 0.55 A / 69 W, (220 V) 0.27 A / 60 W, (250 V) 0.27 A / 68 W, (400 V) 0.15 A / 60 W, (500 V) 0.13 A / 65 W, (600 V) 0.1 A / 60 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 55 kW, (440 V) 55 kW, (500 V) 55 kW, (690 V) 55 kW, (1000 V) 40 kW, (380 / 400 V) 45 kW, (220 / 230 / 240 V) 25 kW |
| Rated Operational Power AC-3e (P<sub>e</sub>) | (415 V) 55 kW, (440 V) 55 kW, (500 V) 55 kW, (690 V) 55 kW, (380 / 400 V) 45 kW, (220 / 230 / 240 V) 25 kW |
| Rated Operational Power AC-6b (P<sub>e</sub>) | (400 / 415 V) 40 °C, 50 / 60 Hz 60 kvar, (400 / 415 V) 70 °C, 50 / 60 Hz 53 kvar, (400 / 415 V) 55 °C, 50 / 60 Hz 60 kvar, (440 V) 40 °C, 50 / 60 Hz 65 kvar, (440 V) 55 °C, 50 / 60 Hz 65 kvar, (440 V) 70 °C, 50 / 60 Hz 58 kvar, (500 / 550 V), 40 °C, 50 / 60 Hz 75 kvar, (500 / 550 V) 55 °C, 50 / 60 Hz 75 kvar, (500 / 550 V) 70 °C, 50 / 60 Hz 70 kvar, (690 V) 40 °C, 50 / 60 Hz 82 kvar, (690 V) 55 °C, 50 / 60 Hz 82 kvar, (690 V) 70 °C, 50 / 60 Hz 75 kvar |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-2 / AC-4) 150 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 230 ... 240 V, 60 Hz 240 ... 260 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 20 V·A, Average Holding Value, from Warm State 6 W, Average Pull-in Value 50 Hz 236 V·A, Average Pull-in Value 60 Hz 260 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 8.2 W, at Rated Operating Conditions AC-3 per Pole 4.5 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 7 ... 21 ms, Between Coil De-energization and NO Contact Opening 5 ... 16 ms, Between Coil Energization and NC Contact Opening 3 ... 17 ms, Between Coil Energization and NO Contact Closing 7 ... 22 ms |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) | 2 x M4 or 2 x M6 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 6 ... 50 mm², Flexible with Insulated Ferrule 1/2x 6 ... 50 mm², Rigid 1x 6 ... 70 mm², Rigid 2x 6 ... 50 mm², Rigid 1x 6 ... 70 mm², Rigid 2x 6 ... 50 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Rigid 1/2x 1 ... 2.5 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Rigid 1/2x 1 ... 2.5 mm² |
| Wire Stripping Length | Control Circuit 10 mm, Main Circuit 17 mm |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| Recommended Screw Driver | Pozidriv PZ |
| Tightening Torque | Auxiliary Circuit 1.2 N·m, Control Circuit 1.2 N·m, Main Circuit 6 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |