| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives. |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Control Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (690 V) 40 °C 125 A, (690 V) 60 °C 100 A, (690 V) 70 °C 85 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (500 V) 60 °C 65 A, (690 V) 60 °C 49 A, (1000 V) 60 °C 25 A, (380 / 400 V) 60 °C 80 A, (220 / 230 / 240 V) 60 °C 80 A |
| Rated Operational Current AC-3e (I<sub>e</sub>) | (415 V) 60 °C 80 A, (440 V) 60 °C 80 A, (500 V) 60 °C 65 A, (690 V) 60 °C 49 A, (380 / 400 V) 60 °C 80 A, (220 / 230 / 240 V) 60 °C 80 A |
| Rated Operational Current DC-1 (I<sub>e</sub>) | (110 V) 2 Poles in Series, 40 °C 125 A, (110 V) 2 Poles in Series, 60 °C 100 A, (110 V) 2 Poles in Series, 70 °C 85 A, (110 V) 3 Poles in Series, 40 °C 125 A, (110 V) 3 Poles in Series, 60 °C 100 A, (110 V) 3 Poles in Series, 70 °C 85 A, (220 V) 3 Poles in Series, 40 °C 125 A, (220 V) 3 Poles in Series, 60 °C 100 A, (220 V) 3 Poles in Series, 70 °C 85 A, (72 V) 1-Pole, 40 °C 125 A, (72 V) 1-Pole, 60 °C 100 A, (72 V) 1-Pole, 70 °C 85 A, (72 V) 2 Poles in Series, 40 °C 125 A, (72 V) 2 Poles in Series, 60 °C 100 A, (72 V) 2 Poles in Series, 70 °C 85 A, (72 V) 3 Poles in Series, 40 °C 125 A, (72 V) 3 Poles in Series, 60 °C 100 A, (72 V) 3 Poles in Series, 70 °C 85 A |
| Rated Operational Current DC-3 (I<sub>e</sub>) | (110 V) 2 Poles in Series, 40 °C 125 A, (110 V) 2 Poles in Series, 60 °C 100 A, (110 V) 2 Poles in Series, 70 °C 85 A, (110 V) 3 Poles in Series, 40 °C 125 A, (110 V) 3 Poles in Series, 60 °C 100 A, (110 V) 3 Poles in Series, 70 °C 85 A, (220 V) 3 Poles in Series, 40 °C 125 A, (220 V) 3 Poles in Series, 60 °C 100 A, (220 V) 3 Poles in Series, 70 °C 85 A, (72 V) 1-Pole, 40 °C 125 A, (72 V) 1-Pole, 60 °C 100 A, (72 V) 1-Pole, 70 °C 85 A, (72 V) 2 Poles in Series, 40 °C 125 A, (72 V) 2 Poles in Series, 60 °C 100 A, (72 V) 2 Poles in Series, 70 °C 85 A, (72 V) 3 Poles in Series, 40 °C 125 A, (72 V) 3 Poles in Series, 60 °C 100 A, (72 V) 3 Poles in Series, 70 °C 85 A |
| Rated Operational Current DC-5 (I<sub>e</sub>) | (110 V) 2 Poles in Series, 40 °C 125 A, (110 V) 2 Poles in Series, 60 °C 100 A, (110 V) 2 Poles in Series, 70 °C 85 A, (110 V) 3 Poles in Series, 40 °C 125 A, (110 V) 3 Poles in Series, 60 °C 100 A, (110 V) 3 Poles in Series, 70 °C 85 A, (110 V) 4 Poles in Series, 40 °C 125 A, (220 V) 3 Poles in Series, 60 °C 100 A, (220 V) 3 Poles in Series, 70 °C 85 A, (72 V) 1-Pole, 40 °C 125 A, (72 V) 1-Pole, 60 °C 100 A, (72 V) 1-Pole, 70 °C 85 A, (72 V) 2 Poles in Series, 40 °C 125 A, (72 V) 2 Poles in Series, 60 °C 100 A, (72 V) 2 Poles in Series, 70 °C 85 A, (72 V) 3 Poles in Series, 40 °C 125 A, (72 V) 3 Poles in Series, 60 °C 100 A, (72 V) 3 Poles in Series, 70 °C 85 A |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (400 V) 37 kW, (415 V) 45 kW, (440 V) 45 kW, (500 V) 45 kW, (690 V) 45 kW, (1000 V) 35 kW, (380 / 400 V) 37 kW, (220 / 230 / 240 V) 22 kW |
| Rated Operational Power AC-3e (P<sub>e</sub>) | (415 V) 45 kW, (440 V) 45 kW, (500 V) 45 kW, (690 V) 45 kW, (380 / 400 V) 37 kW, (220 / 230 / 240 V) 22 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 140 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 450 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1200 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 780 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 300 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 1000 V, acc. to UL/CSA 600 V |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-2 / AC-4) 150 cycles per hour, (AC-3) 1200 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 24 ... 60 V, 60 Hz 24 ... 60 V, DC Operation 20 ... 60 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 4 V·A, Average Holding Value DC 2 W |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 7.6 W, at Rated Operating Conditions AC-3 per Pole 3 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 19 ... 105 ms, Between Coil De-energization and NO Contact Opening 17 ... 100 ms, Between Coil Energization and NC Contact Opening 38 ... 95 ms, Between Coil Energization and NO Contact Closing 42 ... 100 ms |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) | 2 x M4 or 2 x M6 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Rigid Solid 1/2x 1 ... 2.5 mm², Rigid Stranded 1/2x 1 ... 2.5 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| Recommended Screw Driver | Hexagon 4 |
| Tightening Torque | Control Circuit 1.2 N·m, Main Circuit 6 N·m |
| Terminal Type | Ring-Tongue Terminals |
| Product Name | Block Contactor |