ABB 1SBL391201R5100 – AFC80-40-00-51 400-415V50Hz 480V60Hz Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AF Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 1.45 kg |
| UPC / EAN | 3471523024595 |
Shipping & availability
When can 1SBL391201R5100 be shipped?
1SBL391201R5100 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL391201R5100 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL391201R5100 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL391201R5100, subject to availability and destination.
The AFC80-40-00-51 is a 4-pole (4 N.O) - 1000 V IEC or 600 V UL contactor with Screw terminals, mainly controlling power circuits up to 125 A (IEC AC-1) or 105 A UL general use. Within the AF platform, AFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 400 ... 415 V AC 50 Hz / 480 V AC 60 Hz). AFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL391201R5100 |
| Type | AFC80-40-00-51 |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 90 mm |
| Product Net Depth / Length | 116 mm |
| Product Net Height | 125.5 mm |
| Product Net Weight | 1.45 kg |
Technical
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1 |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (690 V) 40 °C 125 A, (690 V) 60 °C 105 A, (690 V) 70 °C 90 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 60 °C 80 A, (440 V) 60 °C 80 A, (500 V) 60 °C 65 A, (690 V) 60 °C 49 A, (1000 V) 60 °C 25 A, (380 / 400 V) 60 °C 80 A, (220 / 230 / 240 V) 60 °C 80 A |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 45 kW, (440 V) 45 kW, (500 V) 45 kW, (690 V) 45 kW, (380 / 400 V) 37 kW, (220 / 230 / 240 V) 22 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 400 ... 415 V, 60 Hz 480 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 20 V·A, Average Holding Value, from Warm State 6 W, Average Pull-in Value 50 Hz 236 V·A, Average Pull-in Value 60 Hz 260 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 8 W, at Rated Operating Conditions AC-3 per Pole 3.2 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 10 ... 19 ms, Between Coil De-energization and NO Contact Opening 5 ... 16 ms, Between Coil Energization and NC Contact Opening 6 ... 15 ms, Between Coil Energization and NO Contact Closing 7 ... 22 ms |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) | 2 x M4 or 2 x M6 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 6 ... 50 mm², Flexible with Insulated Ferrule 1/2x 6 ... 50 mm², Rigid 1x 6 ... 70 mm², Rigid 2x 6 ... 50 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Rigid 1/2x 1 ... 2.5 mm² |
| Wire Stripping Length | Control Circuit 10 mm, Main Circuit 17 mm |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| Recommended Screw Driver | Pozidriv PZ |
| Tightening Torque | Control Circuit 1.2 N·m, Main Circuit 6 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 105 A |
| Tightening Torque UL/CSA | Control Circuit 11 in·lb, Main Circuit 53 in·lb |
Environmental
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C, Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C, Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C |
| Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Pollution Degree | 3 |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100219C0201) | |
| Instructions and Manuals (1SBC101047M6801) | |
| Instructions and Manuals (Part 2) (1SAC200017M0002) |
Certificates (11)
More ABB parts
Available on requestUAFC65-30-00RA-86 400-415V 50Hz 415-440V 60Hz Contactor
Available on requestUAFC65-30-00RA-88 230-240V 50Hz 240-260V 60Hz Contactor
Available on requestAFC80-40-00-34 175V50Hz 208V60Hz Contactor
Available on requestAFC80-40-00-42 230-240V50Hz 277V60Hz Contactor
Available on requestAFC80-40-00-55 500V50Hz 600V60Hz Contactor
Available on requestAFC80-40-00-80 220-230V50Hz 230-240V60Hz Contactor
Available on requestAFC80-40-00-81 24V 50/60Hz Contactor