ABB 1SBL387087R1400 – AF65-30-00-14LU 250-500V50/60HZ-DC Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AF Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.95 kg |
| UPC / EAN | 3471523020764 |
Shipping & availability
When can 1SBL387087R1400 be shipped?
1SBL387087R1400 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL387087R1400 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL387087R1400 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL387087R1400, subject to availability and destination.
The AF65-30-00-14LUdedicated for UL lighting applications. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL387087R1400 |
| Type | AF65-30-00-14LU |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 55 mm |
| Product Net Depth / Length | 111 mm |
| Product Net Height | 125.5 mm |
| Product Net Weight | 0.95 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22 |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Control Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (690 V) 40 °C 105 A, (690 V) 60 °C 90 A, (690 V) 70 °C 80 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 60 °C 65 A, (440 V) 60 °C 65 A, (500 V) 60 °C 55 A, (690 V) 60 °C 39 A, (380 / 400 V) 60 °C 65 A, (220 / 230 / 240 V) 60 °C 65 A |
| Rated Operational Current AC-3e (I<sub>e</sub>) | (415 V) 60 °C 65 A, (440 V) 60 °C 65 A, (500 V) 60 °C 55 A, (690 V) 60 °C 39 A, (380 / 400 V) 60 °C 65 A, (220 / 230 / 240 V) 60 °C 65 A |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (400 V) 30 kW, (415 V) 37 kW, (440 V) 37 kW, (500 V) 37 kW, (690 V) 37 kW, (380 / 400 V) 30 kW, (220 / 230 / 240 V) 18.5 kW |
| Rated Operational Power AC-3e (P<sub>e</sub>) | (415 V) 37 kW, (440 V) 37 kW, (500 V) 37 kW, (690 V) 37 kW, (380 / 400 V) 30 kW, (220 / 230 / 240 V) 18.5 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 690 V, acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-2 / AC-4) 150 cycles per hour, (AC-3) 1200 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 250 ... 500 V, 60 Hz 250 ... 500 V, DC Operation 250 ... 500 V |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 7 W, at Rated Operating Conditions AC-3 per Pole 2.7 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 19 ... 105 ms, Between Coil De-energization and NO Contact Opening 17 ... 100 ms, Between Coil Energization and NC Contact Opening 38 ... 95 ms, Between Coil Energization and NO Contact Closing 42 ... 100 ms |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) | 2 x M4 or 2 x M6 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 4 ... 35 mm², Flexible with Insulated Ferrule 1/2x 4 ... 35 mm², Rigid Stranded 1/2x 6 ... 35 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Rigid Solid 1/2x 1 ... 2.5 mm², Rigid Stranded 1/2x 1 ... 2.5 mm² |
| Wire Stripping Length | Control Circuit 10 mm, Main Circuit 16 mm |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| Tightening Torque | Control Circuit 1.2 N·m, Main Circuit 4 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 90 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 5 hp, (200 ... 208 V AC) Three Phase 20 hp, (220 ... 240 V AC) Three Phase 25, (240 V AC) Single Phase 15 hp, (440 ... 480 V AC) Three Phase 50 hp, (550 ... 600 V AC) Three Phase 60 hp |
| Connecting Capacity Main Circuit UL/CSA | Rigid Stranded 1/2x 10-2 AWG |
| Connecting Capacity Control Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG, Rigid Stranded 1/2x 18-14 AWG |
| Tightening Torque UL/CSA | Control Circuit 11 in·lb, Main Circuit 35 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 56 A, (200 ... 208 V AC) Three Phase 62.1 A, (220 ... 240 V AC) Three Phase 68 A, (240 V AC) Single Phase 68 A, (440 ... 480 V AC) Three Phase 65 A, (550 ... 600 V AC) Three Phase 62 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C |
| Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Closed, Shock Direction: A 25 g, Closed, Shock Direction: B1 25 g, Closed, Shock Direction: B2 15 g, Closed, Shock Direction: C1 25 g, Closed, Shock Direction: C2 25 g, Open, Shock Direction: B1 5 g |
| Resistance to Vibrations | 3g Closed Position & 3g Open Position 5 ... 300 Hz |
| Pollution Degree | 3 |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
ABB EcoSolutions
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line, Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 91.9 % |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4760 >> Lighting Contactors |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (9)
More ABB parts
Available on requestAF65B-30-11-14 250-500V50/60HZ-DC Contactor
Available on requestAFS65-30-22-11 24-60V50/60HZ 20-60VDC Contactor
Available on requestAFS65-30-22-13 100-250V50/60HZ-DC Contactor
Available on requestAF65-30-00-13LU 100-250V50/60HZ-DC Contactor
Available on requestAFC80-30-00-34 175V50Hz 208V60Hz Contactor
Available on requestAFC80-30-11-34 175V50Hz 208V60Hz Contactor
Available on requestAFC80-30-00-42 230-240V50Hz 277V60Hz Contactor
Available on requestAFC80-30-11-42 230-240V50Hz 277V60Hz Contactor