ABB 1SBL371074R8000 – AX65-30-00-80 220-230V50Hz/230-240V60Hz Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 1.01 kg |
| UPC / EAN | 3471522405807 |
Shipping & availability
When can 1SBL371074R8000 be shipped?
1SBL371074R8000 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL371074R8000 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL371074R8000 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL371074R8000, subject to availability and destination.
AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL371074R8000 |
| Type | AX65-30-00-80 |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 70 mm |
| Product Net Depth / Length | 110 mm |
| Product Net Height | 108 mm |
| Product Net Weight | 1.01 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 95 A, (690 V) 40 °C 115 A, (690 V) 70 °C 80 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 65 A, (440 V) 55 °C 65 A, (500 V) 55 °C 55 A, (690 V) 55 °C 43 A, (380 / 400 V) 55 °C 65 A, (220 / 230 / 240 V) 55 °C 65 A |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 37 kW, (440 V) 37 kW, (500 V) 37 kW, (690 V) 37 kW, (380 / 400 V) 30 kW, (220 / 230 / 240 V) 18.5 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-3) 600 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 220 ... 230 V, 60 Hz 230 ... 240 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 18 V·A, Average Holding Value 50 Hz 18 V·A, Average Holding Value 60 Hz 18 V·A, Average Holding Value, from Warm State 5.5 W, Average Pull-in Value 50 Hz 180 V·A, Average Pull-in Value 60 Hz 210 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 6.5 W, at Rated Operating Conditions AC-3 per Pole 1.5 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 7 ... 14 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 7 ... 22 ms, Between Coil Energization and NO Contact Closing 8 ... 27 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| Tightening Torque | Control Circuit 1 N·m, Main Circuit 4 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 90 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 5 hp, (200 ... 208 V AC) Three Phase 20 hp, (220 ... 240 V AC) Three Phase 25, (240 V AC) Single Phase 10 hp, (440 ... 480 V AC) Three Phase 60 hp, (550 ... 600 V AC) Three Phase 75 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 35 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 56 A, (200 ... 208 V AC) Three Phase 62.1 A, (220 ... 240 V AC) Three Phase 68 A, (240 V AC) Single Phase 50 A, (440 ... 480 V AC) Three Phase 77 A, (550 ... 600 V AC) Three Phase 77 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 13712e2a-c3a1-47ea-b805-dd959463341c Bulgaria |
| Simplified SCIP | 24dfb427-1acb-4462-bede-d1f5c723ef17 France, 2e6e0d82-b164-495f-8b7f-bbc04bc60ea3 Croatia, 3caf74ad-a26a-46cf-84cb-a4a16ff79277 Poland, 48a3e8a3-a323-4a6c-983e-81f24d3d6931 Germany, 49a61c88-347a-4497-856c-07d5ed90c003 Spain, 5349b77f-81d9-4b63-ade8-1d44beb1c0d0 Greece, 569618a1-0736-4adc-a98f-9dc925c35bd9 Finland, 5aa7e577-fd2f-4065-b6f3-6cf1494f5034 France, 657bb692-3708-442c-b252-28800db5a23b Estonia, 65b780b9-eaff-4aa0-a395-8ab761bea048 Hungary, 6d45392f-1e6a-491a-9ab1-8e545178cc31 Sweden, 823e250c-1051-45a8-910e-e047a7c5d22e Norway, 85bf450f-cc24-405d-bf22-b7748f47fc7c Italy, 8b08f093-f536-4dfb-a25c-0f8feb7ac929 Germany, 9b0e256a-cf8d-4b83-bd49-0ba6a1924d1b Germany, 9df5c48d-48c7-4cce-889b-b5b1279946e1 Denmark, 9fffa364-4c55-4717-adc6-76525ae1f974 Portugal, c0df309f-87c9-4b24-a390-0064845773d7 Belgium, ca7531bb-dfbb-4eb2-a866-93d0e9843032 Hungary, ce0f5c92-12dd-40fe-9ed2-8c6d3bc567cb Sweden, d488f80e-6911-4d3e-8f73-08cde7b5556b Poland, d5cca434-c189-41e9-90d8-1145fcd3f805 Czechia, d711b468-b266-4f0b-86bf-ffe29a0e2c7f Poland, daba6193-a9c9-432d-abb6-c9750c1c3965 Germany, ede1e254-c352-4422-a30c-e40d0f259178 Belgium, ee5b5f51-5213-424b-9914-31d94d28d9d6 Netherlands, f5827231-b9f2-4374-a083-470b3cdfc99e Germany |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
| E-Number (Finland) | 3707360 |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7059) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX65-30-00-36 190V50Hz/220V60Hz Contactor
Available on requestAX65-30-11-36 190V50Hz/220V60Hz Contactor
Available on requestAX65-30-00-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX65-30-11-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX65-30-11-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX65-30-00-81 24V 50/60Hz Contactor
Available on requestAX65-30-11-81 24V 50/60Hz Contactor
Available on requestAX65-30-00-83 48V 50/60Hz Contactor