Quick facts
| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 1.01 kg |
| UPC / EAN | 3471522403803 |
Shipping & availability
When can 1SBL351074R8000 be shipped?
1SBL351074R8000 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL351074R8000 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL351074R8000 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL351074R8000, subject to availability and destination.
AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL351074R8000 |
| Type | AX50-30-00-80 |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 70 mm |
| Product Net Depth / Length | 110 mm |
| Product Net Height | 108 mm |
| Product Net Weight | 1.01 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 100 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 85 A, (690 V) 40 °C 100 A, (690 V) 70 °C 70 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 50 A, (440 V) 55 °C 45 A, (500 V) 55 °C 45 A, (690 V) 55 °C 35 A, (380 / 400 V) 55 °C 50 A, (220 / 230 / 240 V) 55 °C 53 A |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 25 kW, (440 V) 25 kW, (500 V) 30 kW, (690 V) 30 kW, (380 / 400 V) 22 kW, (220 / 230 / 240 V) 15 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-3) 600 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 220 ... 230 V, 60 Hz 230 ... 240 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 18 V·A, Average Holding Value 50 Hz 18 V·A, Average Holding Value 60 Hz 18 V·A, Average Holding Value, from Warm State 5.5 W, Average Pull-in Value 50 Hz 180 V·A, Average Pull-in Value 60 Hz 210 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 5 W, at Rated Operating Conditions AC-3 per Pole 1.3 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 7 ... 14 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 7 ... 22 ms, Between Coil Energization and NO Contact Closing 8 ... 27 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| Tightening Torque | Control Circuit 1 N·m, Main Circuit 4 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 80 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 3 hp, (200 ... 208 V AC) Three Phase 15 hp, (220 ... 240 V AC) Three Phase 20, (240 V AC) Single Phase 10 hp, (440 ... 480 V AC) Three Phase 40 hp, (550 ... 600 V AC) Three Phase 50 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 35 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 34 A, (200 ... 208 V AC) Three Phase 48.3 A, (220 ... 240 V AC) Three Phase 54 A, (240 V AC) Single Phase 50 A, (440 ... 480 V AC) Three Phase 52 A, (550 ... 600 V AC) Three Phase 52 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 8e5934bd-b1ad-45d3-99ff-14bd34f3d701 Bulgaria |
| Simplified SCIP | 092ea57c-f7d4-44ab-b076-e913290aeaba Germany, 0a060834-034d-40e1-9167-8eb83393c94d France, 14022466-c9a1-4007-9ae3-7920532320e2 Germany, 1a679185-327b-4131-b2d0-fbb3db901e95 Sweden, 1c2d7427-2b93-4227-af61-5456fbd7eef9 Denmark, 1eb5cff9-a438-4660-a991-0024d0468676 Greece, 3127946a-f587-41d1-b1c2-f368c37fdadc Poland, 3bbe40f8-820f-48af-a0ed-9a6c8ad75bc6 Germany, 3e8afc49-96ea-4d9a-a664-d40b49e943c1 Hungary, 4b7b470b-a4be-447a-ab19-26faad4bd73a Belgium, 71456489-563b-4439-9a1a-eeb2ae004fb5 Sweden, 79d1d1a9-5c48-455e-8529-033551b49341 Germany, 85aa4b63-8f66-4742-a40f-01319a4a372d Croatia, 87840595-d49c-43cc-81fe-91c793c002b3 Norway, 97805e70-3645-402e-a986-0b9d206f5e4e France, a70ea036-ace7-44bd-9429-c63180bd2f6c Poland, a8d4af2d-375a-47c7-b0d9-3e7bce0c5f9c Italy, ab8edb45-62c2-487a-993c-22835728e13f Netherlands, bc32fa5c-01cc-4ebe-abe7-d54f160d8263 Germany, bf561d97-199d-49ac-b9f5-0d9cb5d41b02 Hungary, cd48be9b-60b8-4740-8fba-ba59dbdaa600 Czechia, cdd9e0a2-667f-4973-acde-4cca632aad81 Poland, ce06aa7c-c35d-444e-a806-155a123caeff Portugal, d10c5023-45d4-444c-8458-a5a06e1a4f14 Spain, ec2dd648-efa8-486d-9495-b0a677eae119 Belgium, f325f64a-a160-4603-a8cc-ddec6bbb695b Finland, f37fdd47-e8fd-4309-83ee-4b2b6370382e Estonia |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
| E-Number (Finland) | 3707354 |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7059) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX50-30-00-36 190V50Hz/220V60Hz Contactor
Available on requestAX50-30-11-36 190V50Hz/220V60Hz Contactor
Available on requestAX50-30-00-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX50-30-11-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX50-30-11-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX50-30-00-81 24V 50/60Hz Contactor
Available on requestAX50-30-11-81 24V 50/60Hz Contactor
Available on requestAX50-30-00-83 48V 50/60Hz Contactor