ABB 1SBL321074R8301 – AX40-30-01-83 48V 50/60Hz Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.667 kg |
| UPC / EAN | 3471522402837 |
Shipping & availability
When can 1SBL321074R8301 be shipped?
1SBL321074R8301 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL321074R8301 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL321074R8301 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL321074R8301, subject to availability and destination.
AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL321074R8301 |
| Type | AX40-30-01-83 |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 54 mm |
| Product Net Depth / Length | 90 mm |
| Product Net Height | 108.3 mm |
| Product Net Weight | 0.667 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 60 A, (690 V) 40 °C 60 A, (690 V) 70 °C 42 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 40 A, (440 V) 55 °C 37 A, (500 V) 55 °C 33 A, (690 V) 55 °C 25 A, (380 / 400 V) 55 °C 40 A, (220 / 230 / 240 V) 55 °C 40 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A, (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (110 V) 0.55 A / 60 W, (125 V) 1.1 A / 138 W, (220 V) 0.55 A / 121 W, (250 V) 0.55 A / 138 W, (400 V) 2.8 A / 134 W, (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 18.5 kW, (440 V) 22 kW, (500 V) 22 kW, (690 V) 22 kW, (380 / 400 V) 18.5 kW, (220 / 230 / 240 V) 11 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 48 V, 60 Hz 48 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 12 V·A, Average Holding Value 50 Hz 12 V·A, Average Holding Value 60 Hz 12 V·A, Average Holding Value, from Warm State 3 W, Average Pull-in Value 50 Hz 120 V·A, Average Pull-in Value 60 Hz 140 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 3 W, at Rated Operating Conditions AC-3 per Pole 1.3 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 7 ... 14 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 6 ... 18 ms, Between Coil Energization and NO Contact Closing 8 ... 21 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m, Control Circuit 1 N·m, Main Circuit 2.3 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 60 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 3 hp, (200 ... 208 V AC) Three Phase 10 hp, (220 ... 240 V AC) Three Phase 15, (240 V AC) Single Phase 7.5 hp, (440 ... 480 V AC) Three Phase 30 hp, (550 ... 600 V AC) Three Phase 40 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 20 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 34 A, (200 ... 208 V AC) Three Phase 32.2 A, (220 ... 240 V AC) Three Phase 42 A, (240 V AC) Single Phase 40 A, (440 ... 480 V AC) Three Phase 40 A, (550 ... 600 V AC) Three Phase 41 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 5808a41e-3dbc-487c-93c2-77e8b7f63603 Bulgaria |
| Simplified SCIP | 04d6aa1e-2d92-4741-824d-bc6bb032a4ba Greece, 13f50521-c4dc-4e99-825f-1ec021fc2669 Italy, 1bd9b1ad-4134-4f2a-bf76-b5cda95e0d96 Denmark, 1de871d1-d04e-4416-a6c2-b872432edf91 Czechia, 20b68714-2472-43d4-94ab-b93eb05b110f Germany, 2f4e8143-8940-4af9-b337-8447dc68e37b France, 31093eab-a21c-4d0b-82be-cbcb2c3ed71f Germany, 31e7666e-73ac-486d-abee-5a3efc56f1dc Croatia, 387e25ee-cc92-40ad-a623-c82c395a486a Hungary, 5694fdd1-99ca-4eab-9df0-4c3fe5332a7e Poland, 6725fef1-12f7-4cf8-a20a-850776574d14 Hungary, 8e77a526-7575-43c9-ad0d-d13717360ff4 Sweden, 8f9b1258-36a0-4394-8fb6-8810051a3588 Norway, a1aff461-b9bd-477a-9523-fc3e2807fd75 Germany, a2dc13b6-2db7-45a2-a8de-0f0a1787f979 Germany, a387d078-0c73-43af-990f-5cff7853fc4a Estonia, b3b52b13-e0d9-40f3-90e6-3763acb5ec89 Netherlands, b5315edf-5839-4e12-b92d-9971a4626875 Spain, b8499c76-a68b-4bbd-b310-20ab05d9d314 Portugal, bb810f2a-75fb-40b8-84a9-b325d2cf7ddf Poland, bd0516bb-fc6a-4058-81b4-ffeb718f2073 Sweden, bd741075-c222-44fb-9121-ed752bec096e France, cd3d143b-38e8-4c3a-b5a5-3e3b4300b07e Germany, d0c304f7-ede3-4010-829b-71c6662dbffc Finland, df3d04a2-7b89-4ad4-8b9a-6390a373265b Belgium, e1ab5ca6-2745-406c-82b5-03c2fe68d445 Poland, fc3a8002-0869-4084-9911-d1e0f7c9a1b7 Belgium |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7057) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX40-30-01-81 24V 50/60Hz Contactor
Available on requestAX40-30-10-81 24V 50/60Hz Contactor
Available on requestAX40-30-12-81 Block Contactor
Available on requestAX40-30-21-81 Block Contactor
Available on requestAX40-30-10-83 48V 50/60Hz Contactor
Available on requestAX40-30-01-84 110V50Hz/110-120V60Hz Contactor
Available on requestAX40-30-10-84 110V50Hz/110-120V60Hz Contactor
Available on requestAX40-30-01-85 380-400V50Hz/400V-415V60Hz Contactor