ABB 1SBL281074R8501 – AX32-30-01-85 380-400V50Hz/400V-415V60Hz Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.667 kg |
| UPC / EAN | 3471522400857 |
Shipping & availability
When can 1SBL281074R8501 be shipped?
1SBL281074R8501 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL281074R8501 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL281074R8501 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL281074R8501, subject to availability and destination.
AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL281074R8501 |
| Type | AX32-30-01-85 |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 54 mm |
| Product Net Depth / Length | 90 mm |
| Product Net Height | 108.3 mm |
| Product Net Weight | 0.667 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 55 A, (690 V) 40 °C 55 A, (690 V) 70 °C 39 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 32 A, (440 V) 55 °C 32 A, (500 V) 55 °C 28 A, (690 V) 55 °C 21 A, (380 / 400 V) 55 °C 32 A, (220 / 230 / 240 V) 55 °C 32 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A, (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (110 V) 0.55 A / 60 W, (125 V) 1.1 A / 138 W, (220 V) 0.55 A / 121 W, (250 V) 0.55 A / 138 W, (400 V) 2.8 A / 134 W, (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 15 kW, (440 V) 18.5 kW, (500 V) 18.5 kW, (690 V) 18.5 kW, (380 / 400 V) 15 kW, (220 / 230 / 240 V) 9 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 380 ... 400 V, 60 Hz 400 ... 415 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 12 V·A, Average Holding Value 50 Hz 12 V·A, Average Holding Value 60 Hz 12 V·A, Average Holding Value, from Warm State 3 W, Average Pull-in Value 50 Hz 120 V·A, Average Pull-in Value 60 Hz 140 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 2.5 W, at Rated Operating Conditions AC-3 per Pole 0.9 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 7 ... 14 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 6 ... 18 ms, Between Coil Energization and NO Contact Closing 8 ... 21 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m, Control Circuit 1 N·m, Main Circuit 2.3 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 50 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 3 hp, (200 ... 208 V AC) Three Phase 10 hp, (220 ... 240 V AC) Three Phase 10, (240 V AC) Single Phase 7.5 hp, (440 ... 480 V AC) Three Phase 25 hp, (550 ... 600 V AC) Three Phase 30 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 20 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 34 A, (200 ... 208 V AC) Three Phase 32.2 A, (220 ... 240 V AC) Three Phase 28 A, (240 V AC) Single Phase 40 A, (440 ... 480 V AC) Three Phase 34 A, (550 ... 600 V AC) Three Phase 32 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | b6ea104d-87ec-4c98-899e-9ae54d4a7c92 Bulgaria |
| Simplified SCIP | 0e07bd3c-6b7e-43e3-b2b8-0bade6f05d3a Greece, 0e230537-e464-43cb-ab2d-076cb001a343 Germany, 0f09985b-9841-4572-9ff6-63deb59a194e Poland, 11b8a7a8-9806-453c-80d4-69ae88ef593a Finland, 16a4fad3-87b3-4ffd-b982-9890f356bdad Italy, 25c58988-7fb8-4ab0-85c8-c39b61dae64e Germany, 3bc11d69-58fa-4921-8870-ca3d14512bdf Hungary, 4edc78aa-beeb-426a-a2c4-16a6fe5b6c07 France, 5cbdbe56-3770-4b75-b5ac-d2f99bffa1c8 Netherlands, 5fd2ae8e-750b-4386-9659-b37eaaf0cbdc Hungary, 61720fda-ba3b-402a-a06d-ef8357d50991 Norway, 62e91012-6f73-4d59-b41e-66bc7f36c53f Germany, 64808f5b-ef3c-4dc0-a292-7dfbb5d44ad0 Poland, 661b24f5-7f44-467b-ac96-b1b0baac1f14 Germany, 7448d72b-3e7b-4c48-8acf-5a578d8b52d7 Croatia, 79a15697-09f4-4b71-8ad1-230baa57ecb4 Belgium, 9c7e3f7b-74e9-4062-817c-d8e7d862378a Sweden, 9d5b7644-8b30-4d29-ab1e-aaa0504d8f88 Germany, a41ea5d5-65b8-41a7-8bc9-e86dfb9c96c7 Sweden, b2379a22-73a8-4ec8-adbb-d4b92f918488 Estonia, cf7fac2b-02f8-4148-8fce-17d5cfc692e7 Czechia, da01316f-3d8c-4c1a-b955-e6535987c915 France, e01ad423-3bd4-4a1a-8838-a98d87177a55 Denmark, e05c0da3-806d-4220-9097-6280f9deb310 Poland, e2d739e8-c9a9-49b3-abc2-d6b7f8cd7ac6 Spain, e3c18f3a-23ea-4ee7-8e58-95c7296027fe Belgium, e7a24853-878e-46d5-9773-e75d7dc70355 Portugal |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7057) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX32-30-01-83 48V 50/60Hz Contactor
Available on requestAX32-30-10-83 48V 50/60Hz Contactor
Available on requestAX32-30-01-84 110V50Hz/110-120V60Hz Contactor
Available on requestAX32-30-10-84 110V50Hz/110-120V60Hz Contactor
Available on requestAX32-30-10-85 380-400V50Hz/400V-415V60Hz Contactor
Available on requestAX32-30-01-86 400-415V50Hz/415V-440V60Hz Contactor