| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.667 kg |
| Country of origin | India |
| UPC / EAN | 3471522399809 |
Shipping & availability
When can 1SBL281074R8010 be shipped?
1SBL281074R8010 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL281074R8010 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL281074R8010 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL281074R8010, subject to availability and destination.
AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL281074R8010 |
| Type | AX32-30-10-80 |
| Lifecycle | Active (current ABB product) |
| Country of origin | India |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 54 mm |
| Product Net Depth / Length | 90 mm |
| Product Net Height | 108.3 mm |
| Product Net Weight | 0.667 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 55 A, (690 V) 40 °C 55 A, (690 V) 70 °C 39 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 32 A, (440 V) 55 °C 32 A, (500 V) 55 °C 28 A, (690 V) 55 °C 21 A, (380 / 400 V) 55 °C 32 A, (220 / 230 / 240 V) 55 °C 32 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A, (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (110 V) 0.55 A / 60 W, (125 V) 1.1 A / 138 W, (220 V) 0.55 A / 121 W, (250 V) 0.55 A / 138 W, (400 V) 2.8 A / 134 W, (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 15 kW, (440 V) 18.5 kW, (500 V) 18.5 kW, (690 V) 18.5 kW, (380 / 400 V) 15 kW, (220 / 230 / 240 V) 9 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 220 ... 230 V, 60 Hz 230 ... 240 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 12 V·A, Average Holding Value 50 Hz 12 V·A, Average Holding Value 60 Hz 12 V·A, Average Holding Value, from Warm State 3 W, Average Pull-in Value 50 Hz 120 V·A, Average Pull-in Value 60 Hz 140 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 2.5 W, at Rated Operating Conditions AC-3 per Pole 0.9 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 7 ... 14 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 6 ... 18 ms, Between Coil Energization and NO Contact Closing 8 ... 21 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m, Control Circuit 1 N·m, Main Circuit 2.3 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 50 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 3 hp, (200 ... 208 V AC) Three Phase 10 hp, (220 ... 240 V AC) Three Phase 10, (240 V AC) Single Phase 7.5 hp, (440 ... 480 V AC) Three Phase 25 hp, (550 ... 600 V AC) Three Phase 30 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 20 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 34 A, (200 ... 208 V AC) Three Phase 32.2 A, (220 ... 240 V AC) Three Phase 28 A, (240 V AC) Single Phase 40 A, (440 ... 480 V AC) Three Phase 34 A, (550 ... 600 V AC) Three Phase 32 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 9572744b-1e86-4cfe-8086-455619ac353e Bulgaria |
| Simplified SCIP | 1fa2bf05-8d82-4696-9d67-8ca45d1f6807 Finland, 21b2866a-c103-4bcc-b13e-9a79ef47fd9a Hungary, 2258c81c-5dba-48dc-92a4-f3345f0dd577 Germany, 2874ad5b-104f-4107-b8ac-a4ec89dedb51 Croatia, 3f1df392-9ace-44a0-ad36-6f2d094de224 Germany, 467c33ce-a571-4ab7-90e3-9ea49ecaa8f9 Poland, 480e3ed2-c09a-40c4-b6dd-422de23ccaed Poland, 572fba3c-0d3d-411a-84e3-0785ab7e7f66 Czechia, 5a4626c5-d1f8-4c48-9150-a32264a0c112 Denmark, 7712d249-2fb1-440b-b400-760a3de42e2b Germany, 86869519-50f8-41a1-ab4c-02efbc42c380 Estonia, 88851c3c-c854-4b42-b9f8-4b77e4ba05ff Poland, 8e1d6f30-eb59-4784-8dc1-a2ac2a56ecd0 Hungary, 912ab3a7-3917-4348-8dcb-609b2b6fc350 Sweden, 9f6699ed-0aa3-4438-acee-b6e1d8516714 Greece, a5589388-3e31-4a69-b85b-33e11bd8075a Portugal, a7c35f59-a5ee-41e8-9fbf-5c1d616d2518 Belgium, afc1e8c5-35f8-4f9e-a138-9e94dee59fad Belgium, b19d1189-110c-4361-a0c0-e9669be74c1f Italy, b86a8ffe-903d-4d9f-8725-e0eeab4aff5b Norway, c595cfa0-cbee-469a-a4f4-4aafffda296a Germany, c8af027e-e443-4f85-854f-7ed31dce2a3b Sweden, dac9edc9-23ec-48e3-bc03-b5ce9b2010ef France, dd1e0116-108d-45d9-8c88-77b3f0825240 Spain, f9a0001b-b41a-4f9d-8d76-4b948e94ea91 France, fa277581-1eed-4bd0-ad12-c6a65cae10ca Germany, fd766c33-9e6f-490b-aaa0-5a3a783c42a1 Netherlands |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
| E-Number (Finland) | 3707341 |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7057) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX32-30-10-36 190V50Hz/220V60Hz Contactor
Available on requestAX32-30-01-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX32-30-10-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX32-30-01-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX32-30-01-81 24V 50/60Hz Contactor
Available on requestAX32-30-10-81 24V 50/60Hz Contactor
Available on requestAX32-30-01-83 48V 50/60Hz Contactor
Available on requestAX32-30-10-83 48V 50/60Hz Contactor