Available on request

ABB 1SBL157001R1422 – AF12-30-22-14 250-500V50/60HZ-DC Contactor

MPN: 1SBL157001R1422 · Brand: ABB
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryABB AF Contactors
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)
Weight0.36 kg
UPC / EAN3471523110540

Shipping & availability

When can 1SBL157001R1422 be shipped?

1SBL157001R1422 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 1SBL157001R1422 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 1SBL157001R1422 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL157001R1422, subject to availability and destination.

The AF12-30-22-14 is a 3 pole - 690 V IEC or 600 UL contactor with pre-mounted auxiliary contacts and screw terminals, controlling motors up to 5.5 kW / 400 V AC (AC-3) or 7-1/2 hp / 480 V UL and switching power circuits up to 28 A (AC-1) or 28 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Specifications

General

Order code (ABB product ID)1SBL157001R1422
TypeAF12-30-22-14
LifecycleActive (current ABB product)

Ordering

Minimum Order Quantity1 piece
Customs Tariff Number85364900

Dimensions

Product Net Width45 mm
Product Net Depth / Length110.5 mm
Product Net Height86 mm
Product Net Weight0.36 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Number of Poles3P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1
Rated Operational VoltageAuxiliary Circuit 690 V, Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz, Control Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (I<sub>th</sub>)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (I<sub>e</sub>)(690 V) 40 °C 28 A, (690 V) 60 °C 28 A, (690 V) 70 °C 24 A
Rated Operational Current AC-3 (I<sub>e</sub>)(415 V) 60 °C 12 A, (440 V) 60 °C 12 A, (500 V) 60 °C 12.5 A, (690 V) 60 °C 9 A, (380 / 400 V) 60 °C 12 A, (220 / 230 / 240 V) 60 °C 12 A
Rated Operational Current AC-3e (I<sub>e</sub>)(415 V) 60 °C 12 A, (440 V) 60 °C 12 A, (500 V) 60 °C 12.5 A, (690 V) 60 °C 9 A, (380 / 400 V) 60 °C 12 A, (220 / 230 / 240 V) 60 °C 12 A
Rated Operational Current AC-15 (I<sub>e</sub>)(500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (400 / 440 V) 3 A
Rated Operational Current DC-1 (I<sub>e</sub>)(110 V) 1-Pole, 40 °C 15 A, (110 V) 1-Pole, 60 °C 15 A, (110 V) 1-Pole, 70 °C 15 A, (110 V) 2 Poles in Series, 40 °C 27 A, (110 V) 2 Poles in Series, 60 °C 27 A, (110 V) 2 Poles in Series, 70 °C 24 A, (110 V) 3 Poles in Series, 40 °C 27 A, (110 V) 3 Poles in Series, 60 °C 27 A, (110 V) 3 Poles in Series, 70 °C 24 A, (220 V) 2 Poles in Series, 40 °C 15 A, (220 V) 2 Poles in Series, 60 °C 15 A, (220 V) 2 Poles in Series, 70 °C 15 A, (220 V) 3 Poles in Series, 40 °C 27 A, (220 V) 3 Poles in Series, 60 °C 27 A, (220 V) 3 Poles in Series, 70 °C 24 A, (72 V) 1-Pole, 40 °C 27 A, (72 V) 1-Pole, 60 °C 27 A, (72 V) 1-Pole, 70 °C 24 A, (72 V) 2 Poles in Series, 40 °C 27 A, (72 V) 2 Poles in Series, 60 °C 27 A, (72 V) 2 Poles in Series, 70 °C 24 A, (72 V) 3 Poles in Series, 40 °C 27 A, (72 V) 3 Poles in Series, 60 °C 27 A, (72 V) 3 Poles in Series, 70 °C 24 A
Rated Operational Current DC-3 (I<sub>e</sub>)(110 V) 1-Pole, 40 °C 7 A, (110 V) 1-Pole, 60 °C 7 A, (110 V) 1-Pole, 70 °C 7 A, (110 V) 2 Poles in Series, 40 °C 27 A, (110 V) 2 Poles in Series, 60 °C 27 A, (110 V) 2 Poles in Series, 70 °C 24 A, (110 V) 3 Poles in Series, 40 °C 27 A, (110 V) 3 Poles in Series, 60 °C 27 A, (110 V) 3 Poles in Series, 70 °C 24 A, (220 V) 2 Poles in Series, 40 °C 7 A, (220 V) 2 Poles in Series, 60 °C 7 A, (220 V) 2 Poles in Series, 70 °C 7 A, (220 V) 3 Poles in Series, 40 °C 27 A, (220 V) 3 Poles in Series, 60 °C 27 A, (220 V) 3 Poles in Series, 70 °C 24 A, (72 V) 1-Pole, 40 °C 27 A, (72 V) 1-Pole, 60 °C 27 A, (72 V) 1-Pole, 70 °C 24 A, (72 V) 2 Poles in Series, 40 °C 27 A, (72 V) 2 Poles in Series, 60 °C 27 A, (72 V) 2 Poles in Series, 70 °C 24 A, (72 V) 3 Poles in Series, 40 °C 27 A, (72 V) 3 Poles in Series, 60 °C 27 A, (72 V) 3 Poles in Series, 70 °C 24 A
Rated Operational Current DC-5 (I<sub>e</sub>)(110 V) 1-Pole, 40 °C 4 A, (110 V) 1-Pole, 60 °C 4 A, (110 V) 1-Pole, 70 °C 4 A, (110 V) 2 Poles in Series, 40 °C 15 A, (110 V) 2 Poles in Series, 60 °C 15 A, (110 V) 2 Poles in Series, 70 °C 15 A, (110 V) 3 Poles in Series, 40 °C 27 A, (110 V) 3 Poles in Series, 60 °C 27 A, (110 V) 3 Poles in Series, 70 °C 24 A, (220 V) 2 Poles in Series, 40 °C 4 A, (220 V) 2 Poles in Series, 60 °C 4 A, (220 V) 2 Poles in Series, 70 °C 4 A, (220 V) 3 Poles in Series, 40 °C 12 A, (220 V) 3 Poles in Series, 60 °C 12 A, (220 V) 3 Poles in Series, 70 °C 12 A, (72 V) 1-Pole, 40 °C 12 A, (72 V) 1-Pole, 60 °C 12 A, (72 V) 1-Pole, 70 °C 12 A, (72 V) 2 Poles in Series, 40 °C 27 A, (72 V) 2 Poles in Series, 60 °C 27 A, (72 V) 2 Poles in Series, 70 °C 24 A, (72 V) 3 Poles in Series, 40 °C 27 A, (72 V) 3 Poles in Series, 60 °C 27 A, (72 V) 3 Poles in Series, 70 °C 24 A
Rated Operational Current DC-13 (I<sub>e</sub>)(24 V) 6 A / 144 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (125 V) 0.55 A / 69 W, (220 V) 0.27 A / 60 W, (250 V) 0.27 A / 68 W, (400 V) 0.15 A / 60 W, (500 V) 0.13 A / 65 W, (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (P<sub>e</sub>)(400 V) 5.5 kW, (415 V) 5.5 kW, (440 V) 5.5 kW, (500 V) 7.5 kW, (690 V) 7.5 kW, (380 / 400 V) 5.5 kW, (220 / 230 / 240 V) 3 kW
Rated Operational Power AC-3e (P<sub>e</sub>)(415 V) 5.5 kW, (440 V) 5.5 kW, (500 V) 7.5 kW, (690 V) 7.5 kW, (380 / 400 V) 5.5 kW, (220 / 230 / 240 V) 3 kW
Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A, for 0.1 s 140 A, for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Rated Insulation Voltage (U<sub>i</sub>)acc. to IEC 60947-4-1 690 V, acc. to IEC 60947-5-1 690 V, acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (U<sub>imp</sub>)6 kV
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-2 / AC-4) 300 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (U<sub>c</sub>)50 Hz 250 ... 500 V, 60 Hz 250 ... 500 V, DC Operation 250 ... 500 V
Power Lossat 6 A per Pole 0.1 W, at Rated Operating Conditions AC-1 per Pole 1 W, at Rated Operating Conditions AC-3 per Pole 0.2 W
Operate TimeBetween Coil De-energization and NC Contact Closing 13 ... 98 ms, Between Coil De-energization and NO Contact Opening 11 ... 95 ms, Between Coil Energization and NC Contact Opening 38 ... 90 ms, Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M4 Screws Placed Diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 6 mm², Flexible with Insulated Ferrule 1x 0.75 ... 4 mm², Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm², Rigid Solid 1/2x 1 ... 4 mm², Rigid Stranded 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Rigid Solid 1/2x 1 ... 2.5 mm², Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Rigid Solid 1/2x 1 ... 2.5 mm², Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm, Control Circuit 10 mm, Main Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Tightening TorqueAuxiliary Circuit 1.2 N·m, Control Circuit 1.2 N·m, Main Circuit 1.5 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor

Technical UL/CSA

NEMA Size0
Continuous Current Rating NEMA18 A
Horsepower Rating NEMA(115 V AC) Single Phase 1 Hp, (200 V AC) Three Phase 3 Hp, (230 V AC) Single Phase 2 Hp, (230 V AC) Three Phase 3 Hp, (460 V AC) Three Phase 5 Hp, (575 V AC) Three Phase 5 Hp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 28 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 1 hp, (200 ... 208 V AC) Three Phase 3 hp, (220 ... 240 V AC) Three Phase 3, (240 V AC) Single Phase 2 hp, (440 ... 480 V AC) Three Phase 7-1/2 hp, (550 ... 600 V AC) Three Phase 10 hp
Connecting Capacity Main Circuit UL/CSARigid Solid 1/2x 16-10 AWG, Rigid Stranded 1/2x 16-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSARigid Solid 1/2x 18-14 AWG, Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSARigid Solid 1/2x 18-14 AWG, Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb, Control Circuit 11 in·lb, Main Circuit 13 in·lb
Full Load Amps Motor Use(120 V AC) Single Phase 16 A, (200 ... 208 V AC) Three Phase 11 A, (220 ... 240 V AC) Three Phase 9.6 A, (240 V AC) Single Phase 12 A, (440 ... 480 V AC) Three Phase 11 A, (550 ... 600 V AC) Three Phase 11 A

Environmental

Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: B1 25 g, Open, Shock Direction: B1 5 g, Shock Direction: A 30 g, Shock Direction: B2 15 g, Shock Direction: C1 25 g, Shock Direction: C2 25 g
Resistance to Vibrations4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree3

Material Compliance

RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 92.7 %

External Classifications and Standards

Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors

Downloads & documentation

Official documents from ABB, downloaded directly from the manufacturer.

Data sheets & manuals

Data Sheet, Technical Information (1SBC100214C0202)
Instructions and Manuals (1SBC101027M6801)
Instructions and Manuals (Part 2) (1SAC200017M0002)
ABB EcoSolutions Profile (1SBC100156C0308)
End Of Life Disassembling Instructions (1SBC101080M6801)
UL Listing Card (E312527)

CAD & dimension drawings

CAD Dimensional Drawing (2CDC001079B0201)
Certificates (14)
REACH Declaration (2CMT2021-006202)
RoHS Declaration (2CMT2021-006277)
Environmental Product Declaration - EPD (1SBD250584E3000)
A2L Certificate – UL (9AKK108469A4875)
A2L Certificate – UL (9AKK108469A4879)
CQC Certificate (CQC2010010304445624)
CQC Certificate (CQC2020010304298240)
Declaration of Conformity - CCC (2020980304001253)
Declaration of Conformity - CCC (2020980304001082)
Declaration of Conformity - CE (1SBD250000U1000)
Declaration of Conformity - UKCA (1SBD250031U1000)
DNV Certificate (TAE00001AF-5)
UL Certificate (UL-US-2150887-5)
UL Certificate (UL-CA-2142658-5)
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More ABB parts

AF12-30-10-13 100-250V50/60HZ-DC ContactorAvailable on requestAF12-30-10-13 100-250V50/60HZ-DC Contactor
MPN: 1SBL157001R1310 · ABB
Price on request
Request a quote
AF12-30-22-13 100-250V50/60HZ-DC ContactorAvailable on requestAF12-30-22-13 100-250V50/60HZ-DC Contactor
MPN: 1SBL157001R1322 · ABB
Price on request
Request a quote
AF12-30-01-14 250-500V50/60HZ-DC ContactorAvailable on requestAF12-30-01-14 250-500V50/60HZ-DC Contactor
MPN: 1SBL157001R1401 · ABB
Price on request
Request a quote
AF12-30-10-14 250-500V50/60HZ-DC ContactorAvailable on requestAF12-30-10-14 250-500V50/60HZ-DC Contactor
MPN: 1SBL157001R1410 · ABB
Price on request
Request a quote
AF12-30-10K-13M 100-250V50/60HZ-DC Contactor Packaging x 15 PCSAvailable on requestAF12-30-10K-13M 100-250V50/60HZ-DC Contactor Packaging x 15 PCS
MPN: 1SBL157005M1310 · ABB
Price on request
Request a quote
AF12-30-01K-11 24-60V50/60HZ 20-60VDC ContactorAvailable on requestAF12-30-01K-11 24-60V50/60HZ 20-60VDC Contactor
MPN: 1SBL157005R1101 · ABB
Price on request
Request a quote
AF12-30-10K-11 24-60V50/60HZ 20-60VDC ContactorAvailable on requestAF12-30-10K-11 24-60V50/60HZ 20-60VDC Contactor
MPN: 1SBL157005R1110 · ABB
Price on request
Request a quote
AF12-30-01K-12 48-130V50/60HZ-DC ContactorAvailable on requestAF12-30-01K-12 48-130V50/60HZ-DC Contactor
MPN: 1SBL157005R1201 · ABB
Price on request
Request a quote