ABB 1SBL136005R3010 – AF09Z-30-10K-30 24VDC Contactor

MPN: 1SBL136005R3010 · Brand: ABB
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryABB AF Contactors
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)
Weight0.435 kg
UPC / EAN3471523155596

Shipping & availability

When can 1SBL136005R3010 be shipped?

1SBL136005R3010 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 1SBL136005R3010 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 1SBL136005R3010 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL136005R3010, subject to availability and destination.

AF09Z..K 3-pole contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF09Z..K contactors with coil 30 include a 24 V DC electronic coil interface with a built-in surge suppression, obtaining a reduced holding coil consumption up to 1.7 W for a low panel energy consumption and a direct control by PLC-output ≥ 250 mA 24 V DC, without need of additional interface relay.Only AF..Z..-30 contactors need to respect the polarity on the coil terminals (A1+ and A2-). AF09Z..K include Push-in Spring terminals. Only one push is all you need for extremely fast wiring: faster than ever installation, easier than ever wiring, reliable as ever connections. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks. (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Accessories: a wide range of accessories is available.

Specifications

General

Order code (ABB product ID)1SBL136005R3010
TypeAF09Z-30-10K-30
LifecycleActive (current ABB product)

Ordering

Minimum Order Quantity1 piece
Customs Tariff Number85364900

Dimensions

Product Net Width45 mm
Product Net Depth / Length97 mm
Product Net Height92.3 mm
Product Net Weight0.435 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC0
Number of Poles3P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1
Rated Operational VoltageAuxiliary Circuit 690 V, Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (I<sub>e</sub>)(1000 V) 60 °C 25 A, (690 V) 40 °C 25 A, (690 V) 70 °C 22 A
Rated Operational Current AC-3 (I<sub>e</sub>)(415 V) 60 °C 9 A, (440 V) 60 °C 9 A, (500 V) 60 °C 9.5 A, (690 V) 60 °C 7 A, (380 / 400 V) 60 °C 9 A, (220 / 230 / 240 V) 60 °C 9 A
Rated Operational Current AC-3e (I<sub>e</sub>)(415 V) 60 °C 9 A, (440 V) 60 °C 9 A, (500 V) 60 °C 9.5 A, (690 V) 60 °C 7 A, (380 / 400 V) 60 °C 9 A, (220 / 230 / 240 V) 60 °C 9 A
Rated Operational Current AC-15 (I<sub>e</sub>)(500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (400 / 440 V) 3 A
Rated Operational Current DC-1 (I<sub>e</sub>)(110 V) 1-Pole, 40 °C 10 A, (110 V) 1-Pole, 60 °C 10 A, (110 V) 1-Pole, 70 °C 10 A, (110 V) 2 Poles in Series, 40 °C 25 A, (110 V) 2 Poles in Series, 60 °C 25 A, (110 V) 2 Poles in Series, 70 °C 22 A, (110 V) 3 Poles in Series, 40 °C 25 A, (110 V) 3 Poles in Series, 60 °C 25 A, (110 V) 3 Poles in Series, 70 °C 22 A, (220 V) 2 Poles in Series, 40 °C 10 A, (220 V) 2 Poles in Series, 60 °C 10 A, (220 V) 2 Poles in Series, 70 °C 10 A, (220 V) 3 Poles in Series, 40 °C 25 A, (220 V) 3 Poles in Series, 60 °C 25 A, (220 V) 3 Poles in Series, 70 °C 22 A, (72 V) 1-Pole, 40 °C 25 A, (72 V) 1-Pole, 60 °C 25 A, (72 V) 1-Pole, 70 °C 22 A, (72 V) 2 Poles in Series, 40 °C 25 A, (72 V) 2 Poles in Series, 60 °C 25 A, (72 V) 2 Poles in Series, 70 °C 22 A, (72 V) 3 Poles in Series, 40 °C 25 A, (72 V) 3 Poles in Series, 60 °C 25 A, (72 V) 3 Poles in Series, 70 °C 22 A
Rated Operational Current DC-3 (I<sub>e</sub>)(110 V) 1-Pole, 40 °C 6 A, (110 V) 1-Pole, 60 °C 6 A, (110 V) 1-Pole, 70 °C 6 A, (110 V) 2 Poles in Series, 40 °C 25 A, (110 V) 2 Poles in Series, 60 °C 25 A, (110 V) 2 Poles in Series, 70 °C 22 A, (110 V) 3 Poles in Series, 40 °C 25 A, (110 V) 3 Poles in Series, 60 °C 25 A, (110 V) 3 Poles in Series, 70 °C 22 A, (220 V) 2 Poles in Series, 40 °C 6 A, (220 V) 2 Poles in Series, 60 °C 6 A, (220 V) 2 Poles in Series, 70 °C 6 A, (220 V) 3 Poles in Series, 40 °C 25 A, (220 V) 3 Poles in Series, 60 °C 25 A, (220 V) 3 Poles in Series, 70 °C 22 A, (72 V) 1-Pole, 40 °C 25 A, (72 V) 1-Pole, 60 °C 25 A, (72 V) 1-Pole, 70 °C 22 A, (72 V) 2 Poles in Series, 40 °C 25 A, (72 V) 2 Poles in Series, 60 °C 25 A, (72 V) 2 Poles in Series, 70 °C 22 A, (72 V) 3 Poles in Series, 40 °C 25 A, (72 V) 3 Poles in Series, 60 °C 25 A, (72 V) 3 Poles in Series, 70 °C 22 A
Rated Operational Current DC-5 (I<sub>e</sub>)(110 V) 1-Pole, 40 °C 4 A, (110 V) 1-Pole, 60 °C 4 A, (110 V) 1-Pole, 70 °C 4 A, (110 V) 2 Poles in Series, 40 °C 10 A, (110 V) 2 Poles in Series, 60 °C 10 A, (110 V) 2 Poles in Series, 70 °C 10 A, (110 V) 3 Poles in Series, 40 °C 25 A, (110 V) 3 Poles in Series, 60 °C 25 A, (110 V) 3 Poles in Series, 70 °C 22 A, (220 V) 2 Poles in Series, 40 °C 4 A, (220 V) 2 Poles in Series, 60 °C 4 A, (220 V) 2 Poles in Series, 70 °C 4 A, (220 V) 3 Poles in Series, 40 °C 9 A, (220 V) 3 Poles in Series, 60 °C 9 A, (220 V) 3 Poles in Series, 70 °C 9 A, (72 V) 1-Pole, 40 °C 9 A, (72 V) 1-Pole, 60 °C 9 A, (72 V) 1-Pole, 70 °C 9 A, (72 V) 2 Poles in Series, 40 °C 25 A, (72 V) 2 Poles in Series, 60 °C 25 A, (72 V) 2 Poles in Series, 70 °C 22 A, (72 V) 3 Poles in Series, 40 °C 25 A, (72 V) 3 Poles in Series, 60 °C 25 A, (72 V) 3 Poles in Series, 70 °C 22 A
Rated Operational Current DC-13 (I<sub>e</sub>)(24 V) 6 A / 144 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (125 V) 0.55 A / 69 W, (220 V) 0.27 A / 60 W, (250 V) 0.27 A / 68 W, (400 V) 0.15 A / 60 W, (500 V) 0.13 A / 65 W, (600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (P<sub>e</sub>)(415 V) 4 kW, (440 V) 4 kW, (500 V) 5.5 kW, (690 V) 5.5 kW, (380 / 400 V) 4 kW, (220 / 230 / 240 V) 2.2 kW
Rated Operational Power AC-3e (P<sub>e</sub>)(415 V) 4 kW, (440 V) 4 kW, (500 V) 5.5 kW, (690 V) 5.5 kW, (380 / 400 V) 4 kW, (220 / 230 / 240 V) 2.2 kW
Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A, for 0.1 s 140 A, for 1 s 100 A
Rated Insulation Voltage (U<sub>i</sub>)acc. to IEC 60947-4-1 690 V, acc. to IEC 60947-5-1 690 V, acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (U<sub>imp</sub>)6 kV
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour, (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (U<sub>c</sub>)DC Operation 24 V
Coil ConsumptionAverage Holding Value DC 1.7 W, Average Pull-in Value, from Cold State 6 W
Power Lossat 6 A per Pole 0.1 W, at Rated Operating Conditions AC-1 per Pole 1.14 W, at Rated Operating Conditions AC-3 per Pole 0.15 W
Operate TimeBetween Coil De-energization and NC Contact Closing 22 ... 57 ms, Between Coil De-energization and NO Contact Opening 17 ... 29 ms, Between Coil Energization and NC Contact Opening 20 ... 35 ms, Between Coil Energization and NO Contact Closing 27 ... 53 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M4 Screws Placed Diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.5 ... 4 mm², Flexible with Insulated Ferrule 1x 0.5 ... 4 mm², Flexible with Insulated Ferrule 2x 0.5 ... 2.5 mm², Flexible 1/2x 0.5 ... 4 mm², Rigid Solid 1/2x 1 ... 2.5 mm², Rigid Stranded 1/2x 4 ... 6 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.5 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 0.5 ... 1.5 mm², Flexible 1/2x 0.5 ... 2.5 mm², Rigid Solid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.5 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 0.5 ... 1.5 mm², Flexible 1/2x 0.5 ... 2.5 mm², Rigid Solid 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm, Control Circuit 10 mm, Main Circuit 12 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal TypePush-in Spring Terminals
Product NameBlock Contactor

Technical UL/CSA

NEMA Size00
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 25 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 3/4 hp, (200 ... 208 V AC) Three Phase 2 hp, (220 ... 240 V AC) Three Phase 2, (240 V AC) Single Phase 1-1/2 hp, (440 ... 480 V AC) Three Phase 5 hp, (550 ... 600 V AC) Three Phase 7-1/2 hp
Connecting Capacity Main Circuit UL/CSARigid Solid 1/2x 18-14 AWG, Rigid Stranded 1/2x 18-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSARigid Solid 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSARigid Solid 1/2x 18-14 AWG
Full Load Amps Motor Use(120 V AC) Single Phase 13.8 A, (200 ... 208 V AC) Three Phase 7.8 A, (220 ... 240 V AC) Three Phase 6.8 A, (240 V AC) Single Phase 10 A, (440 ... 480 V AC) Three Phase 7.6 A, (550 ... 600 V AC) Three Phase 9 A

Environmental

Ambient Air TemperatureClose to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Vibrations4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree3

Material Compliance

RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 92.7 %

External Classifications and Standards

Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC002552 - Power contactor, DC switching
eClassV11.0 : 27371018
UNSPSC39121529

Downloads & documentation

Official documents from ABB, downloaded directly from the manufacturer.

Data sheets & manuals

Data Sheet, Technical Information (1SBC100214C0202)
Instructions and Manuals (1SBC101054M6801)
Instructions and Manuals (Part 2) (1SAC200017M0002)
ABB EcoSolutions Profile (1SBC100156C0308)
End Of Life Disassembling Instructions (1SBC101080M6801)

CAD & dimension drawings

CAD Dimensional Drawing (2CDC001079B0201)
Certificates (12)
REACH Declaration (2CMT2021-006202)
RoHS Declaration (2CMT2021-006277)
Environmental Product Declaration - EPD (1SBD250584E3000)
CQC Certificate (CQC2010010304445624)
CQC Certificate (CQC2020010304298240)
Declaration of Conformity - CCC (2020980304001253)
Declaration of Conformity - CCC (2020980304001082)
Declaration of Conformity - CE (1SBD250000U1000)
Declaration of Conformity - UKCA (1SBD250031U1000)
DNV Certificate (TAE00001AF-5)
UL Certificate (UL-US-2150887-5)
UL Certificate (UL-CA-2142658-5)
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More ABB parts

AF09Z-30-10K-22 48-130V50/60HZ-DC ContactorAvailable on requestAF09Z-30-10K-22 48-130V50/60HZ-DC Contactor
MPN: 1SBL136005R2210 · ABB
Price on request
Request a quote
AF09Z-30-01K-23 100-250V50/60HZ-DC ContactorAvailable on requestAF09Z-30-01K-23 100-250V50/60HZ-DC Contactor
MPN: 1SBL136005R2301 · ABB
Price on request
Request a quote
AF09Z-30-10K-23 100-250V50/60HZ-DC ContactorAvailable on requestAF09Z-30-10K-23 100-250V50/60HZ-DC Contactor
MPN: 1SBL136005R2310 · ABB
Price on request
Request a quote
AF09Z-30-01K-30 24VDC ContactorAvailable on requestAF09Z-30-01K-30 24VDC Contactor
MPN: 1SBL136005R3001 · ABB
Price on request
Request a quote
AF09ZB-30-01RT-21 24-60V50/60HZ 20-60VDC ContactorAvailable on requestAF09ZB-30-01RT-21 24-60V50/60HZ 20-60VDC Contactor
MPN: 1SBL136060R2101 · ABB
Price on request
Request a quote
AF09ZB-30-10RT-21 24-60V50/60HZ 20-60VDC ContactorAvailable on requestAF09ZB-30-10RT-21 24-60V50/60HZ 20-60VDC Contactor
MPN: 1SBL136060R2110 · ABB
Price on request
Request a quote
AF09ZB-30-01RT-22 48-130V50/60HZ-DC ContactorAvailable on requestAF09ZB-30-01RT-22 48-130V50/60HZ-DC Contactor
MPN: 1SBL136060R2201 · ABB
Price on request
Request a quote
AF09ZB-30-10RT-22 48-130V50/60HZ-DC ContactorAvailable on requestAF09ZB-30-10RT-22 48-130V50/60HZ-DC Contactor
MPN: 1SBL136060R2210 · ABB
Price on request
Request a quote