ABB 1SBL121004R2001 – AS16-30-01S-20 24V50/60HZ Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AS Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.22 kg |
| UPC / EAN | 3471523043206 |
Shipping & availability
When can 1SBL121004R2001 be shipped?
1SBL121004R2001 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL121004R2001 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL121004R2001 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL121004R2001, subject to availability and destination.
AS16 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. The AS..S contactors are the spring terminal version of the AS... range. The AS... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.
Specifications
General
| Order code (ABB product ID) | 1SBL121004R2001 |
| Type | AS16-30-01S-20 |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 45 mm |
| Product Net Depth / Length | 72.5 mm |
| Product Net Height | 68 mm |
| Product Net Weight | 0.22 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Standards | IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 22 A, acc. to IEC 60947-5-1, Θ = 40 °C 10 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (690 V) 40 °C 22 A, (690 V) 60 °C 17 A, (690 V) 70 °C 14 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 60 °C 15.5 A, (440 V) 60 °C 13.6 A, (500 V) 60 °C 12.5 A, (690 V) 60 °C 9 A, (380 / 400 V) 60 °C 15.5 A, (220 / 230 / 240 V) 60 °C 15.7 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (400 / 440 V) 3 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (125 V) 0.55 A / 69 W, (220 V) 0.27 A / 60 W, (250 V) 0.27 A / 68 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (400 V) 7.5 kW, (415 V) 7.5 kW, (440 V) 7.5 kW, (500 V) 7.5 kW, (690 V) 7.5 kW, (220 / 230 / 240 V) 4 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 124 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 22 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 75 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V, acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V, acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-2 / AC-4) 300 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 24 V, 60 Hz 24 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 1.5 V·A, Average Holding Value 50 Hz 1.5 V·A, Average Holding Value 60 Hz 1.2 V·A, Average Pull-in Value 50 Hz 33 V·A, Average Pull-in Value 60 Hz 33 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1.1 W, at Rated Operating Conditions AC-3 per Pole 0.55 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 7 ... 22 ms, Between Coil De-energization and NO Contact Opening 5 ... 19 ms, Between Coil Energization and NC Contact Opening 6 ... 18 ms, Between Coil Energization and NO Contact Closing 9 ... 24 ms |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm², Rigid 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm², Rigid 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm², Rigid 1/2x 0.75 ... 2.5 mm² |
| Wire Stripping Length | Auxiliary Circuit 10 mm, Control Circuit 10 mm, Main Circuit 10 mm |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Terminal Type | Spring Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 15.2 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 3/4 hp, (200 ... 208 V AC) Three Phase 3 hp, (220 ... 240 V AC) Three Phase 5, (240 V AC) Single Phase 2 hp, (440 ... 480 V AC) Three Phase 10 hp, (550 ... 600 V AC) Three Phase 10 hp |
| Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG, Rigid Stranded 1/2x 18-14 AWG |
| Full Load Amps Motor Use | (120 V AC) Single Phase 13.8 A, (200 ... 208 V AC) Three Phase 11 A, (220 ... 240 V AC) Three Phase 15.2 A, (240 V AC) Single Phase 12 A, (440 ... 480 V AC) Three Phase 14 A, (550 ... 600 V AC) Three Phase 11 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C |
| Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Closed, Shock Direction: B1 10 g, Closed, Shock Direction: C1 20 g, Closed, Shock Direction: C2 20 g, Open, Shock Direction: B1 5 g, Open, Shock Direction: C1 9 g, Open, Shock Direction: C2 14 g, Shock Direction: A 20 g, Shock Direction: B2 15 g |
| Resistance to Vibrations | 3g Closed Position & 2g Open Position 5 ... 300 Hz |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4761 >> Magnet contactor, AC-switching |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100214C0202) | |
| Instructions and Manuals (1SBC101020M9701) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
More ABB parts
Available on requestAS16-30-01-26 230V50/60HZ Contactor
Available on requestAS16-30-10-26 230V50/60HZ Contactor
Available on requestAS16-30-32-26 230V50/60HZ Contactor
Available on requestAS16-30-10-28 400V50/60HZ Contactor
Available on requestAS16-30-10S-20 24V50/60HZ Contactor
Available on requestAS16-30-32S-20 24V50/60HZ Contactor
Available on requestAS16-30-01S-25 220V50/60HZ Contactor
Available on requestAS16-30-10S-25 220V50/60HZ Contactor