ABB 1SBH137005R1144

NF44EK-11 24-60V50/60HZ 20-60VDC Contactor Relay

MPN
1SBH137005R1144
EAN
3471523153110
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare ABB parts? We buy surplus →

What is the ABB 1SBH137005R1144?

The NF44EK-11 is a 690 V IEC or 600 UL 8-pole contactor relay with Push-in Spring terminals, used for switching auxiliary and control circuits.

Only one push is all you need for extremely fast wiring: faster than ever installation, easier than ever wiring, reliable as ever connections.

Thanks to the AF technology, the contactor relay has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. NF contactor relays have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

These contactor relays include mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and are side-marked with the "Mechanically Linked" symbol.

Specifications

General

Order code (ABB product ID)1SBH137005R1144
TypeNF44EK-11
LifecycleActive (current ABB product)

Ordering

Minimum Order Quantity1 piece
Customs Tariff Number85364900

Dimensions

Product Net Width45 mm
Product Net Depth / Length110.5 mm
Product Net Height92.3 mm
Product Net Weight0.33 kg

Technical

Number of Auxiliary Contacts NO4
Number of Auxiliary Contacts NC4
Number of Poles8P
StandardsIEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13
Rated Operational VoltageAuxiliary Circuit 690 V, Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz, Control Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (I<sub>th</sub>)acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (I<sub>e</sub>)(500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (400 / 440 V) 3 A
Rated Operational Current DC-13 (I<sub>e</sub>)(24 V) 6 A / 144 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (125 V) 0.55 A / 69 W, (220 V) 0.27 A / 60 W, (250 V) 0.27 A / 68 W, (400 V) 0.15 A / 60 W, (500 V) 0.13 A / 65 W, (600 V) 0.1 A / 60 W
Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>)for 0.1 s 140 A, for 1 s 100 A
Rated Insulation Voltage (U<sub>i</sub>)acc. to IEC 60947-5-1 690 V, acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (U<sub>imp</sub>)6 kV
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour, (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency6000 cycles per hour
Rated Control Circuit Voltage (U<sub>c</sub>)50 Hz 24 ... 60 V, 60 Hz 24 ... 60 V, DC Operation 20 ... 60 V
Power Lossat 6 A per Pole 0.1 W
Operate TimeBetween Coil De-energization and NC Contact Closing 13 ... 98 ms, Between Coil De-energization and NO Contact Opening 11 ... 95 ms, Between Coil Energization and NC Contact Opening 38 ... 90 ms, Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M4 Screws Placed Diagonally
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.5 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 0.5 ... 1.5 mm², Flexible 1/2x 0.5 ... 2.5 mm², Rigid Solid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.5 ... 2.5 mm², Flexible with Insulated Ferrule 1/2x 0.5 ... 1.5 mm², Flexible 1/2x 0.5 ... 2.5 mm², Rigid Solid 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm, Control Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal TypePush-in Spring Terminals
Product NameBlock Contactor Relay

Technical UL/CSA

Connecting Capacity Auxiliary Circuit UL/CSARigid Solid 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSARigid Solid 1/2x 18-14 AWG

Environmental

Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C, Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C, Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Vibrations4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree3

Material Compliance

RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 92.7 %

External Classifications and Standards

Object Classification CodeK
ETIM 7EC000196 - Contactor relay
ETIM 8EC000196 - Contactor relay
ETIM 9EC000196 - Contactor relay
eClassV11.0 : 27371001
UNSPSC39121529
IDEA Granular Category Code (IGCC)4763 >> Power contactor, DC switching
E-Number (Finland)3707949

1SBH137005R1144: frequently asked questions

When can 1SBH137005R1144 be shipped?

1SBH137005R1144 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 1SBH137005R1144 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 1SBH137005R1144 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBH137005R1144, subject to availability and destination.

More ABB parts

ABB 1SBH137001R1480 – NF80E-14 250-500V50/60HZ-DC Contactor Relay
ABB
1SBH137001R1480

NF80E-14 250-500V50/60HZ-DC Contactor Relay

ABB 1SBH137005R1122 – NF22EK-11 24-60V50/60HZ 20-60VDC Contactor Relay
ABB
1SBH137005R1122

NF22EK-11 24-60V50/60HZ 20-60VDC Contactor Relay

ABB 1SBH137005R1131 – NF31EK-11 24-60V50/60HZ 20-60VDC Contactor Relay
ABB
1SBH137005R1131

NF31EK-11 24-60V50/60HZ 20-60VDC Contactor Relay

ABB 1SBH137005R1140 – NF40EK-11 24-60V50/60HZ 20-60VDC Contactor Relay
ABB
1SBH137005R1140

NF40EK-11 24-60V50/60HZ 20-60VDC Contactor Relay

ABB 1SBH137005R1153 – NF53EK-11 24-60V50/60HZ 20-60VDC Contactor Relay
ABB
1SBH137005R1153

NF53EK-11 24-60V50/60HZ 20-60VDC Contactor Relay

ABB 1SBH137005R1162 – NF62EK-11 24-60V50/60HZ 20-60VDC Contactor Relay
ABB
1SBH137005R1162

NF62EK-11 24-60V50/60HZ 20-60VDC Contactor Relay

ABB 1SBH137005R1171 – NF71EK-11 24-60V50/60HZ 20-60VDC Contactor Relay
ABB
1SBH137005R1171

NF71EK-11 24-60V50/60HZ 20-60VDC Contactor Relay

ABB 1SBH137005R1180 – NF80EK-11 24-60V50/60HZ 20-60VDC Contactor Relay
ABB
1SBH137005R1180

NF80EK-11 24-60V50/60HZ 20-60VDC Contactor Relay

ABB 1SBH137005R1144Price and lead time confirmed within 1 business day
Request a Quote