ABB 1SBH131001R5539 – NFC33/11-55 500V50Hz 600V60Hz Contactor Relay
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB NF Contactor Relays |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.358 kg |
| UPC / EAN | 3471525003291 |
Shipping & availability
When can 1SBH131001R5539 be shipped?
1SBH131001R5539 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBH131001R5539 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBH131001R5539 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBH131001R5539, subject to availability and destination.
The NFC33/11-55 is a contactor relay with 8 auxiliary contacts (4 N.O including 1 leading contact + 4 N.C including 1 lagging contact) and screw terminals, used to switch auxiliary and control circuits. Within the AF platform, NFC contactors offer an optimized operating time for AC controlled applications with electromagnetic coil (control voltage : 500V50Hz 600V60Hz). NFC contactors have a block type design and can be easily extended with add-on auxiliary contact blocks and a wide range of additionnal accessories.
Specifications
General
| Order code (ABB product ID) | 1SBH131001R5539 |
| Type | NFC33/11-55 |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 45 mm |
| Product Net Depth / Length | 110.5 mm |
| Product Net Height | 86 mm |
| Product Net Weight | 0.358 kg |
Technical
| Number of Main Contacts NO | 0 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 4 |
| Number of Auxiliary Contacts NC | 4 |
| Number of Poles | 8P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Control Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (400 / 440 V) 3 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (125 V) 0.55 A / 69 W, (220 V) 0.27 A / 60 W, (250 V) 0.27 A / 68 W, (400 V) 0.15 A / 60 W, (500 V) 0.13 A / 65 W, (600 V) 0.1 A / 60 W |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | for 0.1 s 140 A, for 1 s 100 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-5-1 690 V, acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 0 cycles per hour, (AC-15) 1200 cycles per hour, (AC-2 / AC-4) 0 cycles per hour, (AC-3) 0 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 6000 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 500 V, 60 Hz 600 V |
| Coil Consumption | 2.3 W |
| Power Loss | at 6 A per Pole 0.1 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 9 ... 20 ms, Between Coil De-energization and NO Contact Opening 4 ... 18 ms, Between Coil Energization and NC Contact Opening 7 ... 21 ms, Between Coil Energization and NO Contact Closing 10 ... 26 ms |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) | 2 x M4 Screws Placed Diagonally |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Rigid Solid 1/2x 1 ... 2.5 mm², Rigid Stranded 1/2x 1 ... 2.5 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Rigid Solid 1/2x 1 ... 2.5 mm², Rigid Stranded 1/2x 1 ... 2.5 mm² |
| Wire Stripping Length | Auxiliary Circuit 10 mm, Control Circuit 10 mm |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| Recommended Screw Driver | Pozidriv PZ |
| Tightening Torque | Auxiliary Circuit 1.2 N·m, Control Circuit 1.2 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor Relay |
Technical UL/CSA
| Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG, Rigid Stranded 1/2x 18-14 AWG |
| Tightening Torque UL/CSA | Auxiliary Circuit 11 in·lb, Control Circuit 11 in·lb |
Environmental
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C, Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C, Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C |
| Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Closed, Shock Direction: B1 25 g, Open, Shock Direction: B1 5 g, Shock Direction: A 30 g, Shock Direction: B2 15 g, Shock Direction: C1 25 g |
| Resistance to Vibrations | 4g Closed Position & 2g Open position 5 ... 300 Hz |
| Pollution Degree | 3 |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | K |
| ETIM 7 | EC000196 - Contactor relay |
| ETIM 8 | EC000196 - Contactor relay |
| ETIM 9 | EC000196 - Contactor relay |
| eClass | V11.0 : 27371001 |
| UNSPSC | 39121500 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100219C0201) | |
| Instructions and Manuals (1SBC101027M6801) | |
| Instructions and Manuals (Part 2) (1SAC200017M0002) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (12)
More ABB parts
Available on requestNFC71E-51 400-415V50Hz 480V60Hz Contactor Relay
Available on requestNFC80E-51 400-415V50Hz 480V60Hz Contactor Relay
Available on requestNFC22E-55 500V50Hz 600V60Hz Contactor Relay
Available on requestNFC31E-55 500V50Hz 600V60Hz Contactor Relay
Available on requestNFC40E-55 500V50Hz 600V60Hz Contactor Relay
Available on requestNFC44E-55 500V50Hz 600V60Hz Contactor Relay
Available on requestNFC53E-55 500V50Hz 600V60Hz Contactor Relay
Available on requestNFC51/11-55 500V50Hz 600V60Hz Contactor Relay