Quick facts
| Availability | Confirmed on request |
| Category | ABB Installation Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.14 kg |
Shipping & availability
When can 1SBE111111M0402 be shipped?
1SBE111111M0402 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBE111111M0402 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBE111111M0402 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBE111111M0402, subject to availability and destination.
The ESB16..N installation contactors are used to control single loads up to 16 A and can be operated by AC or DC.
These contactors are made for use in household applications as well as in industrial environments.
The following benefits are provided:
Hum-free operation, low power consumption and integrated overvoltage protection.
Various contact combinations and accessories are available.
Specifications
General
| Order code (ABB product ID) | 1SBE111111M0402 |
| Type | ESB16-02N-04 |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 12 piece |
| Customs Tariff Number | 85365080 |
Dimensions
| Product Net Width | 18 mm |
| Product Net Depth / Length | 65 mm |
| Product Net Height | 85 mm |
| Product Net Weight | 0.14 kg |
Technical
| Number of Main Contacts NO | 0 |
| Number of Main Contacts NC | 2 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 2P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, IEC 60335-2-40 A2L |
| Rated Operational Voltage | Main Circuit 220 V DC, Main Circuit 240 V AC |
| Rated Frequency (f) | Control Circuit DC, Control Circuit 50 Hz, Control Circuit 60 Hz, Control Circuit 400 Hz, Main Circuit DC, Main Circuit 50 Hz, Main Circuit 60 Hz |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (NC) 16 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (230 V) Single Phase, NC 6 A |
| Rated Operational Current AC-7a (I<sub>e</sub>) | (NC) 16 A |
| Rated Operational Current AC-7b (I<sub>e</sub>) | (230 V) Single Phase, NC 6 A |
| Rated Operational Power AC-1 (P<sub>e</sub>) | (230 V) Single Phase, NC 3.7 kW |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (230 V) Single Phase, NC 0.9 kW |
| Rated Operational Power AC-7a (P<sub>e</sub>) | (230 V) Single Phase, NC 3.7 kW |
| Rated Operational Power AC-7b (P<sub>e</sub>) | (230 V) Single Phase, NC 0.9 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A |
| Rated Insulation Voltage (U<sub>i</sub>) | 400 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | 6 kV |
| Electrical Durability | AC-1 (NC) 150000 cycle, AC-3 (NC) 150000 cycle, AC-7a (NC) 150000 cycle, AC-7b (NC) 150000 cycle |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour, (AC-3) 600 cycles per hour, (AC-7a) 300 cycles per hour, (AC-7b) 600 cycles per hour |
| Mechanical Durability | Nr. Operations 1000000 cycle |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 110 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 2.5 V·A, Average Holding Value DC 2.5 W, Average Pull-in Value 50 Hz 2.5 V·A, Average Pull-in Value 60 Hz 2.5 V·A, Average Pull-in Value DC 2.5 W |
| Power Loss | at Rated Operating Conditions AC-1 per Pole NC 0.9 W |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1x 1 ... 6 mm², Flexible with Ferrule 2x 1 ... 2.5 mm², Flexible with Insulated Ferrule 1x 1 ... 6 mm², Flexible with Insulated Ferrule 2x 1 ... 1.5 mm², Flexible 1x 1 ... 6 mm², Flexible 2x 1 ... 4 mm², Rigid 1x 1 ... 10 mm², Rigid 2x 1 ... 4 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1x 0.75 ... 2.5 mm², Flexible with Ferrule 2x 0.75 ... 1.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1 mm², Flexible 1x 1 ... 2.5 mm², Flexible 2x 1 ... 1.5 mm², Rigid 1x 0.5 ... 4 mm², Rigid 2x 0.75 ... 2.5 mm² |
| Wire Stripping Length | Control Circuit 7 mm, Main Circuit 10 mm |
| Degree of Protection | IP20 |
| Recommended Screw Driver | Control Circuit Pozidriv 1, Main Circuit Pozidriv 1 |
| Tightening Torque | Control Circuit 0.9 N·m, Main Circuit 1.2 N·m |
| Terminal Type | Screw Terminals |
| Width in Number of Modular Spacings | 1 |
| Product Name | Installation Contactor |
Technical UL/CSA
| Maximum Operating Voltage UL/CSA | Main Circuit 240 V AC |
| General Use Rating UL/CSA | (acc. to UL 240 V) 16 A |
| Horsepower Rating UL/CSA | (220 ... 240 V AC) Single Phase, NC 0.75 Hp |
| Connecting Capacity Main Circuit UL/CSA | Solid 14-8 AWG, Stranded 14-8 AWG |
| Connecting Capacity Control Circuit UL/CSA | Solid 16-10 AWG, Stranded 16-10 AWG |
| Tightening Torque UL/CSA | Control Circuit 8 in·lb, Main Circuit 11 in·lb |
| Full Load Amps Motor Use | (220 ... 240 V AC) Single Phase, NC 6.9 A |
Environmental
| Ambient Air Temperature | Operation -25 ... +55 °C, Storage -40 ... +80 °C |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 15g |
| Pollution Degree | 3 |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| WEEE B2C / B2B | Business To Consumer |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
ABB EcoSolutions
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 87.4 % |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC001653 - Installation contactor for distribution board |
| ETIM 8 | EC001653 - Installation contactor for distribution board |
| ETIM 9 | EC001653 - Installation contactor for distribution board |
| eClass | V11.0 : 27142308 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4759 >> Installation contactor for distribution board |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (12)
More ABB parts
Available on requestESB16-20N-02 Installation Contactor (NO) 16 A - 2 NO - 0 NC - 42 V - Control Circuit DC
Available on requestESB16-02N-03 Installation Contactor (NC) 16 A - 0 NO - 2 NC - 48 V - Control Circuit DC
Available on requestESB16-11N-03 Installation Contactor (NC) 16 A - 1 NO - 1 NC - 48 V - Control Circuit DC
Available on requestESB16-20N-03 Installation Contactor (NO) 16 A - 2 NO - 0 NC - 48 V - Control Circuit DC
Available on requestESB16-11N-04 Installation Contactor (NC) 16 A - 1 NO - 1 NC - 110 V - Control Circuit DC
Available on requestESB16-20N-04 Installation Contactor (NO) 16 A - 2 NO - 0 NC - 110 V - Control Circuit DC
Available on requestESB16-02N-05 Installation Contactor (NC) 16 A - 0 NO - 2 NC - 240 V - Control Circuit DC
Available on requestESB16-11N-05 Installation Contactor (NC) 16 A - 1 NO - 1 NC - 240 V - Control Circuit DC