ABB 1SAZ421301R1001 – TA200DU-90-V1000 Thermal Overload Relay 66 ... 90 A
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB Thermal Overload Relays |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.755 kg |
| UPC / EAN | 4013614305894 |
Shipping & availability
When can 1SAZ421301R1001 be shipped?
1SAZ421301R1001 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SAZ421301R1001 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SAZ421301R1001 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SAZ421301R1001, subject to availability and destination.
The TA200DU-90-V1000 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
Specifications
General
| Order code (ABB product ID) | 1SAZ421301R1001 |
| Type | TA200DU-90-V1000 |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 104 mm |
| Product Net Height | 151 mm |
| Product Net Depth / Length | 126 mm |
| Product Net Weight | 0.755 kg |
Technical
| Setting Range | 66 ... 90 A |
| Rated Operational Voltage | Auxiliary Circuit 440 V DC, Auxiliary Circuit 500 V AC, Main Circuit 690 V AC, Main Circuit 440 V DC |
| Rated Operational Current (I<sub>e</sub>) | 90 A |
| Rated Frequency (f) | Auxiliary Circuit 50 Hz, Auxiliary Circuit 60 Hz, Auxiliary Circuit DC, Main Circuit 60 Hz, Main Circuit 50 Hz, Main Circuit DC |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV, Main Circuit 6 kV |
| Rated Insulation Voltage (U<sub>i</sub>) | 690 V |
| Number of Poles | 3P |
| Number of Auxiliary Contacts NC | 1 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Protected Poles | 3 |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | Auxiliary Circuit NC 10 A, Auxiliary Circuit NO 6 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (120 V) NC 3 A, (120 V) NO 1.5 A, (240 V) NC 3 A, (240 V) NO 1.2 A, (400 V) NC 0.75 A, (400 V) NO 0.37 A, (440 V) NC 0.75 A, (440 V) NO 0.37 A, (500 V) NC 0.3 A, (500 V) NO 0.25 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (125 V) NC 0.25 A, (125 V) NO 0.25 A, (24 V) NC 1.25 A, (24 V) NO 1.25 A, (250 V) NC 0.12 A, (250 V) NO 0.04 A, (60 V) NC 0.25 A, (60 V) NO 0.25 A |
| Degree of Protection | Housing IP20, Main Circuit Terminals IP00 |
| Pollution Degree | 3 |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible 1/2x 0.75 ... 2.5 mm², Rigid 1/2x 0.75 ... 4 mm² |
| Connecting Capacity Main Circuit | Hole Diameter > 10 mm², Rigid or Flexible with Cable Lug 1x 25 ... 120 mm² |
| Tightening Torque | Auxiliary Circuit 1 ... 1.3 N·m, Main Circuit 25 N·m |
| Wire Stripping Length | Auxiliary Circuit 9 mm |
| Recommended Screw Driver | Auxiliary Circuit Pozidriv 1, Main Circuit Open Bars |
| Mounting Position | 1 ... 6 |
| Power Loss | at Rated Operating Conditions per Pole 2.4 ... 4.5 W |
| Suitable For | A145, A185, AF145, AF185, AF190, AF205 |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 |
Technical UL/CSA
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Contact Rating UL/CSA | (NO:) B600, (NC:) C600 |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1x 4-0000 AWG, Stranded 1x 4-0000 AWG |
| Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 18-14 AWG, Stranded 1/2x 18-14 AWG |
| Tightening Torque UL/CSA | Auxiliary Circuit 12 in·lb, Main Circuit 220 in·lb |
Environmental
| Ambient Air Temperature | Operation -5 ... +40 °C, Operation Compensated -5 ... +40 °C, Storage -40 ... +70 °C |
| Ambient Air Temperature Compensation | Yes |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 12g |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Material Compliance
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
ABB EcoSolutions
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 62.6 % |
External Classifications and Standards
| Object Classification Code | F |
| ETIM 9 | EC000106 - Thermal overload relay |
| ETIM 10 | EC000106 - Thermal overload relay |
| eClass | V11.0 : 27371501 |
| UNSPSC | 39121520 |
| IDEA Granular Category Code (IGCC) | 5364 >> Overload relay |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (16)
More ABB parts
Available on requestTA200DU-135 Thermal Overload Relay 100 ... 135 A
Available on requestTA200DU-150 Thermal Overload Relay 110 ... 150 A
Available on requestTA200DU-175 Thermal Overload Relay 130 ... 175 A
Available on requestTA200DU-200 Thermal Overload Relay 150 ... 200 A
Available on requestTA200DU-110-V1000 Thermal Overload Relay 80 ... 110 A
Available on requestTA200DU-135-V1000 Thermal Overload Relay 100 ... 135 A
Available on requestTA200DU-150-V1000 Thermal Overload Relay 110 ... 150 A
Available on requestTA200DU-175-V1000 Thermal Overload Relay 130 ... 175 A