What is the ABB 1SAL100182R9901?

The MC1A310ARJ mini contactor is a dimension optimized 3 pole contactor with 1 NO auxiliary contact and special screw terminals for a connection with ring tongue ferrules. This device is a great solution when high performances are needed but the space is limited. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 4 kW (AC-3) and 20 A / 690 V (AC-1) or switching of control signals. The product is suitable for wall or rail mounting.

Specifications

General

Order code (ABB product ID)1SAL100182R9901
TypeMC1A310ARJ
LifecycleActive (current ABB product)

Ordering

Minimum Order Quantity1 piece
Customs Tariff Number85365080

Dimensions

Product Net Width45 mm
Product Net Depth / Length56 mm
Product Net Height48 mm
Product Net Weight0.17 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC0
Number of Poles3P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, UL 60947-5-1
Rated Operational VoltageAuxiliary Circuit 690 V AC, Auxiliary Circuit 440 V DC, Main Circuit 690 V AC, Main Circuit 440 V DC
Rated Frequency (f)Auxiliary Circuit 50 Hz, Auxiliary Circuit 60 Hz, Auxiliary Circuit DC, Control Circuit 50 Hz, Control Circuit 60 Hz, Main Circuit 50 Hz, Main Circuit 60 Hz, Main Circuit DC
Conventional Free-air Thermal Current (I<sub>th</sub>)Auxiliary Circuit 10 A, Main Circuit 20 A
Rated Operational Current AC-1 (I<sub>e</sub>)(690 V) 55 °C 20 A, (690 V) 70 °C 16 A, (230 V) 55 °C 20 A, (230 V) 70 °C 16 A, (400 V) 55 °C 20 A, (400 V) 70 °C 16 A, (500 V) 55 °C 20 A, (500 V) 70 °C 16 A
Rated Operational Current AC-3 (I<sub>e</sub>)(230 V) 55°C 9 A, (400 V) 55 °C 9 A, (500 V) 55 °C 8 A, (690 V) NO 55°C 5 A
Rated Operational Current AC-15 (I<sub>e</sub>)(240 V) 6 A, (400 V) 4 A, (500 V) 2.5 A, (690 V) 1.5 A
Rated Operational Current DC-13 (I<sub>e</sub>)(24 V) 5 A, (48 V) 2.5 A, (125 V) 0.55 A, (250 V) 0.3 A, (440 V) 0.15 A
Rated Operational Power AC-3 (P<sub>e</sub>)(230 V) Three Phase 2.2 kW, (400 V) Three Phase 4 kW, (500 V) Three Phase 4 kW, (690 V) Three Phase, NO 4 kW
Rated Breaking Capacity AC-38 x Ie / AC-3
Rated Making Capacity AC-310 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (U<sub>i</sub>)750 V
Rated Impulse Withstand Voltage (U<sub>imp</sub>)Auxiliary Circuit 6 kV, Main Circuit 6 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour, (AC-15) 360 cycles per hour, (AC-3) 1200 cycles per hour, (DC-1) 600 cycles per hour, (DC-13) 360 cycles per hour, (DC-3) 600 cycles per hour
Mechanical DurabilityNr. Operations 10000000 cycle
Minimum Switching CapacityAuxiliary Circuit 17 V, Auxiliary Circuit 5 mA
Coil Operating Limits(acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (U<sub>c</sub>)50 Hz 110 ... 115 V AC, 60 Hz 110 ... 120 V AC
Coil ConsumptionAverage Holding Value 50 Hz 5.3 V·A, Average Pull-in Value 50 Hz 5.3 V·A
Power Lossat Rated Operating Conditions AC-1 per Pole 0.7 W
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main CircuitFlexible 1/2x 0.75 ... 2.5 mm², Rigid 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible 1/2x 0.75 ... 2.5 mm², Rigid 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible 1/2x 0.75 ... 2.5 mm², Rigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 9 mm, Control Circuit 9 mm, Main Circuit 9 mm
Degree of ProtectionAuxiliary Circuit Terminals IP20, Control Circuit Terminals IP20, Main Circuit Terminals IP20
Recommended Screw DriverPozidriv 2
Tightening TorqueAuxiliary Circuit 0.8 ... 1.0 N·m, Control Circuit 0.8 N·m, Main Circuit 0.8 ... 1.0 N·m
Terminal TypeRing-Tongue Terminals
Mini Contactor TypeMini Contactor
Product NameMini Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
General Use Rating UL/CSA(600 V AC) 20 A
Horsepower Rating UL/CSA(115 V AC) Single Phase 0.5 Hp, (200 V AC) Three Phase 3 Hp, (220 ... 240 V AC) Three Phase 3 Hp, (230 V AC) Single Phase 1.5 Hp, (440 ... 480 V AC) Three Phase 5 Hp, (550 ... 600 V AC) Three Phase 5 Hp
Connecting Capacity Main Circuit UL/CSAStranded 1/2x 18-12 AWG
Connecting Capacity Auxiliary Circuit UL/CSAStranded 1/2x 18-12 AWG
Contact Rating UL/CSAA600, Q600
Tightening Torque UL/CSAAuxiliary Circuit 7 in·lb, Control Circuit 7 in·lb, Main Circuit 7 in·lb
Full Load Amps Motor Use(115 V AC) Single Phase 9.8 A, (200 V AC) Three Phase 11 A, (220 ... 240 V AC) Three Phase 9.6 A, (230 V AC) Single Phase 10 A, (440 ... 480 V AC) Three Phase 7.6 A, (550 ... 600 V AC) Three Phase 6.1 A

Environmental

Ambient Air TemperatureOperation -40 ... +70 °C, Storage -55 ... +80 °C
Maximum Operating Altitude Permissible3000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to Vibrations5g 3 ... 150 Hz

Material Compliance

RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)

External Classifications and Standards

Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
E-Number (Finland)3709427

1SAL100182R9901: frequently asked questions

When can 1SAL100182R9901 be shipped?

1SAL100182R9901 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 1SAL100182R9901 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 1SAL100182R9901 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SAL100182R9901, subject to availability and destination.

More ABB parts

ABB 1SAH220458R9900 – MCRC040ATWLMini Contactor Relay125 V DC4NO0NCScrew Terminals
ABB
1SAH220458R9900

MCRC040ATWLMini Contactor Relay125 V DC4NO0NCScrew Terminals

ABB 1SAH220463R9900 – MCRC040ATWGMini Contactor Relay48 V DC4NO0NCScrew Terminals
ABB
1SAH220463R9900

MCRC040ATWGMini Contactor Relay48 V DC4NO0NCScrew Terminals

ABB 1SAL100046R9902 – Mini Contactor MC2 60 Hz 208 ... 220 V AC - 3 NO - 0 NC - Screw Terminals
ABB
1SAL100046R9902

Mini Contactor MC2 60 Hz 208 ... 220 V AC - 3 NO - 0 NC - Screw Terminals

ABB 1SAL100175R9901 – Mini Contactor MC1 50 Hz 110 ... 115 V AC - 3 NO - 0 NC - Ring-Tongue Terminals
ABB
1SAL100175R9901

Mini Contactor MC1 50 Hz 110 ... 115 V AC - 3 NO - 0 NC - Ring-Tongue Terminals

ABB 1SAL100210R9901 – Mini Contactor MC1 12 V DC - 3 NO - 0 NC - Screw Terminals
ABB
1SAL100210R9901

Mini Contactor MC1 12 V DC - 3 NO - 0 NC - Screw Terminals

ABB 1SAL100213R9901 – Mini Contactor MC1 50 Hz 110 ... 115 V AC - 3 NO - 0 NC - Screw Terminals
ABB
1SAL100213R9901

Mini Contactor MC1 50 Hz 110 ... 115 V AC - 3 NO - 0 NC - Screw Terminals

ABB 1SAL100214R9901 – Mini Contactor MC1 50 Hz 220 ... 240 V AC - 3 NO - 0 NC - Screw Terminals
ABB
1SAL100214R9901

Mini Contactor MC1 50 Hz 220 ... 240 V AC - 3 NO - 0 NC - Screw Terminals

ABB 1SAL100215R9901 – Mini Contactor MC1 50 Hz 380 ... 400 V AC - 3 NO - 0 NC - Screw Terminals
ABB
1SAL100215R9901

Mini Contactor MC1 50 Hz 380 ... 400 V AC - 3 NO - 0 NC - Screw Terminals

ABB 1SAL100182R9901Price and lead time confirmed within 1 business day
Request a Quote