Pepperl Fuchs NBB2-F29-E3 – Inductive sensor
Pepperl Fuchs
NBB2-F29-E3

Inductive sensor

Pepperl Fuchs NBN6-V3-E0 – Inductive sensor
Pepperl Fuchs
NBN6-V3-E0

Inductive sensor

Pepperl Fuchs NBN6-V3-E1 – Inductive sensor
Pepperl Fuchs
NBN6-V3-E1

Inductive sensor

Pepperl Fuchs NBN6-V3-E3 – Inductive sensor
Pepperl Fuchs
NBN6-V3-E3

Inductive sensor

Compare Inductive Sensors

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNOrder code (Pepperl+Fuchs part number)Rated operating distanceAssured operating distanceReduction factor rAlMTTFd
NEN40-30GM60-E3-V123157640 mm sn0 ... 32.4 mm sa0.42211 a
NEN40-30GM60-E023157540 mm sn0 ... 32.4 mm sa0.42211 a
NEN40-30GM60-E223157440 mm sn0 ... 32.4 mm sa0.42211 a
NEB22-30GM60-E0-V123157322 mm sn0 ... 17.8 mm sa0.25213 a
NEB22-30GM60-E3-V123157222 mm sn0 ... 17.8 mm sa0.25213 a
NEB22-30GM60-E023157122 mm sn0 ... 17.8 mm sa0.25213 a
NEB22-30GM60-E223157022 mm sn0 ... 17.8 mm sa0.25213 a
NBB2-F29-E32224362 mm sn0 ... 1.62 mm sa0.21680 a
NBN6-V3-E2-V32252476 mm sn0 ... 4.8 mm sa0.351920 a
NBB3-V3-E2-V32252433 mm sn0 ... 2.4 mm sa0.351440 a
NBN8-F1-A2-V312304428 mm sn0 ... 6.48 mm sa0.451530 a
NBB20-L2-A2-V1-M22331720 mm sn0 ... 16.2 mm sa0.34695 a
NBN40-L2-A0-V1-M22331640 mm sn0 ... 32.4 mm sa0.34670 a
NBN8-F1-A0-V312304418 mm sn0 ... 6.48 mm sa0.451530 a
NBB4-F1-A2-V312304404 mm sn0 ... 3.24 mm sa0.41640 a
NBB4-F1-A0-V312304394 mm sn0 ... 3.24 mm sa0.41530 a
NCN8-18GM60-B3B-V12308298 mm sn0 ... 6.48 mm sa0.42926 a
NBB1,5-F79-E2-2M2287231.5 mm sn0 ... 1.215 mm sa0.34830 a
NBN40-U4L-A2-V121402640 mm sn0 ... 32.4 mm sa0.391310 a
NBB3-V3-E1-V32252423 mm sn0 ... 2.43 mm sa0.352300 a
NBB3-V3-E0-V32252413 mm sn0 ... 2.43 mm sa0.352300 a
NBN6-V3-E02252376 mm sn0 ... 4.8 mm sa0.352300 a
NBN6-V3-E12252386 mm sn0 ... 4.8 mm sa0.352300 a
NBN6-V3-E32252406 mm sn0 ... 4.8 mm sa0.352300 a

Common to all listed parts

Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Standard conformity: StandardsEN IEC 60947-5-2