Inductive Sensors Parts

Showing 1,081–1,104 of 3,075 parts
Pepperl Fuchs NJ10-30GK-N – Inductive sensor
Pepperl Fuchs
NJ10-30GK-N

Inductive sensor

Pepperl Fuchs NJ6-22-N-G – Inductive sensor
Pepperl Fuchs
NJ6-22-N-G

Inductive sensor

Pepperl Fuchs NJ6-22-N-5M – Inductive sensor
Pepperl Fuchs
NJ6-22-N-5M

Inductive sensor

Pepperl Fuchs NJ6-22-N – Inductive sensor
Pepperl Fuchs
NJ6-22-N

Inductive sensor

Pepperl Fuchs NJ10-22-N-G – Inductive sensor
Pepperl Fuchs
NJ10-22-N-G

Inductive sensor

Pepperl Fuchs NJ10-22-N – Inductive sensor
Pepperl Fuchs
NJ10-22-N

Inductive sensor

Compare Inductive Sensors

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNOrder code (Pepperl+Fuchs part number)Reduction factor r304Switching frequencyCable: LengthHysteresis
NJ10-30GK-N-15M701333100.850 ... 300 Hz f15 m L—
NJ10-30GK-N701333090.850 ... 300 Hz f2 m L1 ... 10 % typ. 5 % H
NJ10-30GKK-N701333080.850 ... 300 Hz f——
NCN15-30GM40-N0-V1701333070.70 ... 150 Hz f—1 ... 15 % typ. 5 % H
NCN15-30GM40-N0-30M701333060.70 ... 150 Hz f30 m L5 ... 15 % typ. 5 % H
NCN15-30GM40-N0-20M701333050.70 ... 150 Hz f20 m L1 ... 15 % typ. 6 % H
NCN15-30GM40-N0-10M701333040.70 ... 150 Hz f10 m L1 ... 15 % typ. 6 % H
NCB15-30GM40-N0-5M701333010.760 ... 450 Hz f5 m L1 ... 15 % typ. 5 % H
NCB15-30GM40-N0-10M701333000.760 ... 450 Hz f10 m L1 ... 15 % typ. 5 % H
NCB10-30GM40-N0-5M-OG701332990.720 ... 650 Hz f5 m L1 ... 10 % typ. 5 % H
NCB10-30GM40-N0-50M701332970.750 ... 200 Hz f50 m L1 ... 15 % typ. 5 % H
NCB10-30GM40-N0-15M-OG701332960.720 ... 650 Hz f15 m L1 ... 10 % typ. 5 % H
NCB10-30GM40-N0-10M-OG701332940.720 ... 650 Hz f10 m L1 ... 10 % typ. 5 % H
NCB10-30GM40-N0-10M701332930.750 ... 200 Hz f10 m L1 ... 15 % typ. 5 % H
NCB10-30GK40-N0701332920.750 ... 200 Hz f2 m L1 ... 15 % typ. 5 % H
NJ6-22-N-G-5M701332910.850 ... 2000 Hz f5 m Ltyp. % H
NJ6-22-N-G-15M701332900.850 ... 2000 Hz f15 m Ltyp. % H
NJ6-22-N-G701332890.850 ... 2000 Hz f2 m Ltyp. % H
NJ6-22-N-5M701332880.850 ... 2000 Hz f5 m Ltyp. % H
NJ6-22-N-10M701332870.850 ... 2000 Hz f10 m L1 ... 7 % typ. 4 % H
NJ6-22-N701332860.850 ... 2000 Hz f2 m L1 ... 7 % typ. 4 % H
NJ10-22-N-G-5M701332850.850 ... 2000 Hz f5 m Ltyp. 3 % H
NJ10-22-N-G701332840.850 ... 2000 Hz f2 m Ltyp. 3 % H
NJ10-22-N701332800.850 ... 2000 Hz f2 m L1 ... 9 % typ. 5 % H

Common to all listed parts

Switching functionNormally closed (NC)
Output typeNAMUR
LifecycleActive (current Pepperl+Fuchs product)
Nominal voltage8.2 V (Ri approx. 1 kΩ) Uo
Current consumption: Measuring plate detected≤ 1 mA
Standard conformity: NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
Standard conformity: StandardsEN IEC 60947-5-2
IECEx approval: Equipment protection level GbIECEx PTB 11.0037X