MPNOrder code (Pepperl+Fuchs part number)Detection rangeBlack-white difference (6 %/90 %)Diameter of the light spotDevice ID
OBT40-R101-2P1-IO-V31-IR267075-10051510 ... 40 mmapprox. 1 mmapprox. 3 mm at 40 mm0x11050A (1115402)
OBT40-R101-2P1-IO-V31267075-10053210 ... 40 mmapprox. 1 mmapprox. 3 mm at 40 mm0x110503 (1115395)
OBT40-R101-2P1-IO-0,3M-V1267075-10053310 ... 40 mmapprox. 1 mmapprox. 3 mm at 40 mm0x110503 (1115395)
OBT40-R101-2P1-IO267075-10053110 ... 40 mmapprox. 1 mmapprox. 3 mm at 40 mm0x110503 (1115395)
OBT20-R102-2P1-IO-V31-IR267075-1005477 ... 20 mmapprox. 1 mmapprox. 1.5 mm at 20 mm0x110519 (1115417)
OBT20-R102-2P1-IO-V31267075-1005457 ... 20 mmapprox. 1 mmapprox. 1.5 mm at 20 mm0x110511 (1115409)
OBT20-R102-2P1-IO-0,3M-V1267075-1005467 ... 20 mmapprox. 1 mmapprox. 1.5 mm at 20 mm0x110511 (1115409)
OBT20-R102-2P1-IO267075-1005447 ... 20 mmapprox. 1 mmapprox. 1.5 mm at 20 mm0x110511 (1115409)
OBT20-R101-2P1-IO-V31-IR267075-1005137 ... 20 mmapprox. 1 mmapprox. 1.5 mm at 20 mm0x110509 (1115401)
OBT20-R101-2P1-IO-V31267075-1005287 ... 20 mmapprox. 1 mmapprox. 1.5 mm at 20 mm0x110501 (1115393)
OBT20-R101-2P1-IO-0,3M-V31267075-1005297 ... 20 mmapprox. 1 mmapprox. 1.5 mm at 20 mm0x110501 (1115393)
OBT20-R101-2P1-IO-0,3M-V1267075-1005307 ... 20 mmapprox. 1 mmapprox. 1.5 mm at 20 mm0x110501 (1115393)
OBT20-R101-2P1-IO267075-1005277 ... 20 mmapprox. 1 mmapprox. 1.5 mm at 20 mm0x110501 (1115393)
OBT350-R100-2EP1-IO-IR267075-1005735 ... 350 mm< 15 % at 350 mmapprox. 26 mm at a distance of 350 mm0x110610 (1115664)
OBT350-R100-2EP-IO-0,3M-V31-IR267075-1005745 ... 350 mm< 15 % at 350 mmapprox. 26 mm at a distance of 350 mm0x11060A (1115658)
RLK23/RT-BHMS 590472650 ... 500 mm< 5 %12 mm at 500 mm sensor range—
ML100-8-H-200-IR/102/115e701471925 ... 200 mm< 20 % at 200 mmapprox. 12 mm at a distance of 200 mm—
OBT80-R3-P1-P7014202615 ... 80 mm< 20 %approx. 5 mm at a distance of 80 mm—
OBT80-R3-P1-0,2M-V3-P7014202215 ... 80 mm< 20 %approx. 5 mm at a distance of 80 mm—
OBT80-R3-P1-0,2M-V3-P-L7014202420 ... 80 mm< 15 % at 80 mmapprox. 2 mm at a distance of 80 mm—
OBT80-R3-P1-P-L7014202720 ... 80 mm< 15 % at 80 mmapprox. 2 mm at a distance of 80 mm—
OBT80-R3-E0-0,2M-V31-P-L7014193120 ... 80 mm< 15 % at 80 mmapprox. 2 mm at a distance of 80 mm—
OBT80-R2-E0-0,2M-V31-P-L7014192920 ... 80 mm< 15 % at 80 mmapprox. 2 mm at a distance of 80 mm—
OBT80-R3-E0-0,2M-V31-P7014192115 ... 80 mm< 20 %approx. 5 mm at a distance of 80 mm—

Common to all listed parts

Diagnostic Coverage (DC)0 %