DBS60 Parts

Showing 169–192 of 554 parts

Compare DBS60

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNPulses per revolutionCommunication Interface detailSupply voltageShort-circuit protection of the outputsShaft diameter
DBS60E-R5FPC10241,024TTL / HTL / HTL 1)4.5 ... 30 V✔ 2)12 mmRear clamping
DBS60E-RBEPC10241,024HTL / Push pull10 ... 27 V✔ 2)8 mmRear clamping
DBS60E-TGAK040964,096TTL / RS-4224.5 ... 5.5 V✔ 2)14 mmFront clamp
DBS60E-R1AJC10241,024TTL / RS-4224.5 ... 5.5 V✔ 2)6 mmRear clamping
DBS60E-BHFJC10241,024TTL / HTL / HTL 1)4.5 ... 30 V✔ 2)15 mmFront clamp
DBS60E-TEFAC10241,024TTL / HTL / HTL 1)4.5 ... 30 V✔ 1)12 mmFront clamp
DBS60E-TBAAC10241,024TTL / RS-4224.5 ... 5.5 V✔ 1)8 mmFront clamp
DBS60E-B2CPD10241,024TTL / RS-42210 ... 30 V✔ 2)8 mmFront clamp
DBS60E-TGEJD005050HTL / Push pull10 ... 27 V✔ 2)14 mmFront clamp
DBS60E-TECCC50005,000TTL / RS-42210 ... 30 V✔ 1)12 mmFront clamp
DBS60E-S1CP00100100TTL / RS-42210 ... 30 V✔ 2)6 mmWith flat
DBS60E-BDAN040964,096TTL / RS-4224.5 ... 5.5 V✔ 2)10 mmFront clamp
DBS60E-RAAAD10241,024TTL / RS-4224.5 ... 5.5 V✔ 1)6 mmRear clamping
DBS60E-RACJD10241,024TTL / RS-42210 ... 30 V✔ 2)6 mmRear clamping
DBS60E-THAP0004848TTL / RS-4224.5 ... 5.5 V✔ 2)15 mmFront clamp
DBS60E-R5FQD10241,024TTL / HTL / HTL 1)4.5 ... 30 V✔ 3)12 mmRear clamping
DBS60E-BGECB020050HTL / Push pull10 ... 27 V✔ 1)14 mmFront clamp
DBS60E-R1ACD10241,024TTL / RS-4224.5 ... 5.5 V✔ 1)6 mmRear clamping
DBS60E-R3AQ00100100TTL / RS-4224.5 ... 5.5 V✔ 3)3/8″Rear clamping
DBS60E-B8FJC10241,024TTL / HTL / HTL 1)4.5 ... 30 V✔ 2)15 mmFront clamp
DBS60E-BDEAC10241,024HTL / Push pull10 ... 27 V✔ 1)10 mmFront clamp
DBS60E-BDEA020482,048HTL / Push pull10 ... 27 V✔ 1)10 mmFront clamp
DBS60E-TBCQD10241,024TTL / RS-42210 ... 30 V✔ 3)8 mmFront clamp
DBS60E-R7FQD10241,024TTL / HTL / HTL 1)4.5 ... 30 V✔ 3)14 mmRear clamping

Common to all listed parts

MTTFD (mean time to dangerous failure)500Â years (ENÂ ISOÂ 13849-1)Â 1)
Measuring step≤ 90°, electric/pulses per revolution
Error limitsMeasuring step deviation x 3
Communication interfaceIncremental
Number of signal channels6-channel
Load current≤ 30 mA, per channel
Reference signal, number1
Reference signal, position90°, electric, logically gated with A and B