DBS60 Parts

Showing 97–120 of 554 parts

Compare DBS60

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNPulses per revolutionCommunication Interface detailSupply voltageShort-circuit protection of the outputsShaft diameter
DBS60E-TJAPC10241,024TTL / RS-4224.5 ... 5.5 V✔ 2)5/8″Front clamp
DBS60E-B1AA00100100TTL / RS-4224.5 ... 5.5 V✔ 1)6 mmFront clamp
DBS60E-RDEPD10241,024HTL / Push pull10 ... 27 V✔ 2)10 mmRear clamping
DBS60E-S4EC00180180HTL / Push pull10 ... 27 V✔ 1)10 mmWith flat
DBS60E-T2FCD10241,024TTL / HTL / HTL 1)4.5 ... 30 V✔ 1)8 mmFront clamp
DBS60E-T1EP00100100HTL / Push pull10 ... 27 V✔ 2)6 mmFront clamp
DBS60E-TFFPC10241,024TTL / HTL / HTL 1)4.5 ... 30 V✔ 2)1/2″Front clamp
DBS60E-RFEPC10241,024HTL / Push pull10 ... 27 V✔ 2)1/2″Rear clamping
DBS60E-RHENK0360360HTL / Push pull10 ... 27 V✔ 2)15 mmRear clamping
DBS60E-TCCA00100100TTL / RS-42210 ... 30 V✔ 1)3/8″Front clamp
DBS60E-B8FCC10241,024TTL / HTL / HTL 1)4.5 ... 30 V✔ 1)15 mmFront clamp
DBS60E-TCFAD10241,024TTL / HTL / HTL 1)4.5 ... 30 V✔ 1)3/8″Front clamp
DBS60E-T8FQD10241,024TTL / HTL / HTL 1)4.5 ... 30 V✔ 3)15 mmFront clamp
DBS60E-RCAC00100100TTL / RS-4224.5 ... 5.5 V✔ 1)3/8″Rear clamping
DBS60E-S3FK050005,000TTL / HTL / HTL 1)4.5 ... 30 V✔ 2)6 mmWith flat
DBS60E-S3EC020482,048HTL / Push pull10 ... 27 V✔ 1)6 mmWith flat
DBS60E-BCEJC10241,024HTL / Push pull10 ... 27 V✔ 2)3/8″Front clamp
DBS60E-THEC00100100HTL / Push pull10 ... 27 V✔ 1)15 mmFront clamp
DBS60E-RDEA010241,024HTL / Push pull10 ... 27 V✔ 1)10 mmRear clamping
DBS60E-THFKD20482,048TTL / HTL / HTL 1)4.5 ... 30 V✔ 2)15 mmFront clamp
DBS60E-BJAK020482,048TTL / RS-4224.5 ... 5.5 V✔ 2)5/8″Front clamp
DBS60E-BGCJ00100100TTL / RS-42210 ... 30 V✔ 2)14 mmFront clamp
DBS60E-RAAPD10241,024TTL / RS-4224.5 ... 5.5 V✔ 2)6 mmRear clamping
DBS60E-RDFA00100100TTL / HTL / HTL 1)4.5 ... 30 V✔ 1)10 mmRear clamping

Common to all listed parts

MTTFD (mean time to dangerous failure)500Â years (ENÂ ISOÂ 13849-1)Â 1)
Measuring step≤ 90°, electric/pulses per revolution
Error limitsMeasuring step deviation x 3
Communication interfaceIncremental
Number of signal channels6-channel
Load current≤ 30 mA, per channel
Reference signal, number1
Reference signal, position90°, electric, logically gated with A and B