DBS60 Parts

Showing 361–384 of 554 parts

Compare DBS60

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNPulses per revolutionCommunication Interface detailSupply voltageShort-circuit protection of the outputsShaft diameter
DBS60E-B2AP00100100TTL / RS-4224.5 ... 5.5 V✔ 2)8 mmFront clamp
DBS60E-T2EJC10241,024HTL / Push pull10 ... 27 V✔ 2)8 mmFront clamp
DBS60E-BDCC010241,024TTL / RS-42210 ... 30 V✔ 1)10 mmFront clamp
DBS60E-R1APD10241,024TTL / RS-4224.5 ... 5.5 V✔ 2)6 mmRear clamping
DBS60E-BHEKB20002,000HTL / Push pull10 ... 27 V✔ 2)15 mmFront clamp
DBS60E-TAEA00100100HTL / Push pull10 ... 27 V✔ 1)6 mmFront clamp
DBS60E-R5EA00100100HTL / Push pull10 ... 27 V✔ 1)12 mmRear clamping
DBS60E-TACQC10241,024TTL / RS-42210 ... 30 V✔ 3)6 mmFront clamp
DBS60E-R8FP00100100TTL / HTL / HTL 1)4.5 ... 30 V✔ 2)15 mmRear clamping
DBS60E-S3EA00100100HTL / Push pull10 ... 27 V✔ 1)6 mmWith flat
DBS60E-RAFA020482,048TTL / HTL / HTL 1)4.5 ... 30 V✔ 1)6 mmRear clamping
DBS60E-RFACC10241,024TTL / RS-4224.5 ... 5.5 V✔ 1)1/2″Rear clamping
DBS60E-RCEJ00100100HTL / Push pull10 ... 27 V✔ 2)3/8″Rear clamping
DBS60E-BFEA00100100HTL / Push pull10 ... 27 V✔ 1)1/2″Front clamp
DBS60E-TAFAC20482,048TTL / HTL / HTL 1)4.5 ... 30 V✔ 1)6 mmFront clamp
DBS60E-BFEPC10241,024HTL / Push pull10 ... 27 V✔ 2)1/2″Front clamp
DBS60E-T6APD10241,024TTL / RS-4224.5 ... 5.5 V✔ 2)1/2″Front clamp
DBS60E-S3EQ00512512HTL / Push pull10 ... 27 V✔ 3)6 mmWith flat
DBS60E-T2CAD10241,024TTL / RS-42210 ... 30 V✔ 1)8 mmFront clamp
DBS60E-BGAQD20002,000TTL / RS-4224.5 ... 5.5 V✔ 3)14 mmFront clamp
DBS60E-T2AAD10241,024TTL / RS-4224.5 ... 5.5 V✔ 1)8 mmFront clamp
DBS60E-BFEJ00100100HTL / Push pull10 ... 27 V✔ 2)1/2″Front clamp
DBS60E-TBEQ00100100HTL / Push pull10 ... 27 V✔ 3)8 mmFront clamp
DBS60E-R7FC00100100TTL / HTL / HTL 1)4.5 ... 30 V✔ 1)14 mmRear clamping

Common to all listed parts

MTTFD (mean time to dangerous failure)500Â years (ENÂ ISOÂ 13849-1)Â 1)
Measuring step≤ 90°, electric/pulses per revolution
Measuring step deviation± 18° / pulses per revolution
Error limitsMeasuring step deviation x 3
Duty cycle≤ 0.5 ± 5 %
Communication interfaceIncremental
Number of signal channels6-channel
Load current≤ 30 mA, per channel