CytroPac small power units Parts
























Compare CytroPac small power units
Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.
| MPN | Operating pressure, max. [bar] | Max. flow [l/min] | Cooling capacity, max. [kW] | Conformity | Weight [kg] |
|---|---|---|---|---|---|
| R901501100 | 50.0 | 35.0 | 2 | CE | 63 |
| R901501099 | 50.0 | 35.0 | 1.5 | CE | 63 |
| R901501098 | 50.0 | 35.0 | 1 | CE | 63 |
| R901501097 | 50.0 | 35.0 | — | CE | 63 |
| R901522124 | 70.0 | 32.0 | 2 | CE; cULus listed | 67 |
| R901501096 | 70.0 | 32.0 | 2 | CE | 63 |
| R901501095 | 70.0 | 32.0 | 1.5 | CE | 63 |
| R901522119 | 70.0 | 32.0 | 1 | CE; cULus listed | 67 |
| R901501094 | 70.0 | 32.0 | 1 | CE | 63 |
| R901501093 | 70.0 | 32.0 | — | CE | 63 |
| R901550012 | 70.0 | 32.0 | 2 | CE | 63 |
| R901546136 | 70.0 | 32.0 | 2 | CE | 0 |
| R901501088 | 70.0 | 32.0 | 2 | CE | 63 |
| R901501087 | 70.0 | 32.0 | 1.5 | CE | 63 |
| R901531778 | 70.0 | 32.0 | 1 | CE | 0 |
| R901501086 | 70.0 | 32.0 | 1 | CE | 63 |
| R901501085 | 70.0 | 32.0 | — | CE | 63 |
| R901522122 | 100.0 | 22.0 | 2 | CE; cULus listed | 67 |
| R901501084 | 100.0 | 22.0 | 2 | CE | 63 |
| R901501083 | 100.0 | 22.0 | 1.5 | CE | 63 |
| R901522118 | 100.0 | 22.0 | 1 | CE; cULus listed | 67 |
| R901501082 | 100.0 | 22.0 | 1 | CE | 63 |
| R901501081 | 100.0 | 22.0 | — | CE | 63 |
| R901550011 | 100.0 | 22.0 | 2 | CE | 63 |
Common to all listed parts
| Product family | CytroPac |
| Oscillating volume [l] | 10 |
| Supply voltage | 380…480 VAC (-15%/+10%) |
| Tank capacity [l] | 20 |
| Performance class [kW] | 2.2 |
| Hydraulic fluid | HLP |