DGC Parts








Compare DGC
Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.
| MPN | Stroke | Piston diameter | Cushioning length | Theoretical force at 0.6 MPa (6 bar, 87 psi), return stroke | Theoretical force at 0.6 MPa (6 bar, 87 psi), advance stroke |
|---|---|---|---|---|---|
| DGC-63- - | 1, 5000 mm | 63 mm | 31.1 mm | 1870 N | 1870 N |
| DGC-50- - | 1, 5000 mm | 50 mm | 29.8 mm | 1178 N | 1178 N |
| DGC-40- - | 1, 8500 mm | 40 mm | 29.5 mm | 754 N | 754 N |
| DGC-32- - | 1, 8500 mm | 32 mm | 17.5 mm | 483 N | 483 N |
| DGC-25- - | 1, 8500 mm | 25 mm | 15.5 mm | 295 N | 295 N |
| DGC-18- - | 1, 3000 mm | 18 mm | 16.5 mm | 153 N | 153 N |
| DGC-12- - | 1, 2000 mm | 12 mm | — | 68 N | 68 N |
| DGC-8- - | 1, 2000 mm | 8 mm | — | 30 N | 30 N |
Common to all listed parts
| Mounting position | optional |
| Position detection | Via proximity switch |
| Variants | Additional slide, standard, on left, Additional slide, standard, on right |
| Mode of operation | Double-acting |
| CE mark (see declaration of conformity) | To EU Explosion Protection Directive (ATEX) |
| UKCA marking (see declaration of conformity) | To UK EX instructions |
| Explosion protection certification outside the EU | EPL Dc (GB), EPL Gb (GB) |
| Explosion protection | Zone 1 (ATEX), Zone 1 (UKEX), Zone 2 (ATEX), Zone 22 (ATEX), Zone 22 (UKEX) |