Manifold directional control valves Parts

Showing 2,209–2,232 of 3,143 parts
Danfoss 843AN00012A – DG4V-3-2N208-VM-U-HH7-60, DG4V32N208VMUHH760
Danfoss
843AN00012A

DG4V-3-2N208-VM-U-HH7-60, DG4V32N208VMUHH760

Danfoss 843AN00010A – DG4V-3-6C208-VM-U-HH7-60, DG4V36C208VMUHH760
Danfoss
843AN00010A

DG4V-3-6C208-VM-U-HH7-60, DG4V36C208VMUHH760

Danfoss 843AN00009A – DG4V-3-8C208-VM-U-HH7-60, DG4V38C208VMUHH760
Danfoss
843AN00009A

DG4V-3-8C208-VM-U-HH7-60, DG4V38C208VMUHH760

Danfoss 843AN00008A – DG4V-3-0C208-VM-U-HH7-60, DG4V30C208VMUHH760
Danfoss
843AN00008A

DG4V-3-0C208-VM-U-HH7-60, DG4V30C208VMUHH760

Danfoss 833AN00391A – DG4V-3-6C-M-FPA5WL-B8-60, DG4V36CMFPA5WLB860
Danfoss
833AN00391A

DG4V-3-6C-M-FPA5WL-B8-60, DG4V36CMFPA5WLB860

Danfoss 833AN00371A – DG4V-3-0C-M-FW-B8-60, DG4V30CMFWB860
Danfoss
833AN00371A

DG4V-3-0C-M-FW-B8-60, DG4V30CMFWB860

Danfoss 833AN00361A – DG4V-3-6C-M-FW-B8-60, DG4V36CMFWB860
Danfoss
833AN00361A

DG4V-3-6C-M-FW-B8-60, DG4V36CMFWB860

Danfoss 833AN00360A – DG4V-3-6C-M-FTWL-B8-60, DG4V36CMFTWLB860
Danfoss
833AN00360A

DG4V-3-6C-M-FTWL-B8-60, DG4V36CMFTWLB860

Danfoss 833AN00350A – DG4V-3-6C-M-U-G7-60-P20 -EN214, DG4V36CMUG760P20
Danfoss
833AN00350A

DG4V-3-6C-M-U-G7-60-P20 -EN214, DG4V36CMUG760P20

Danfoss 833AN00349A – DG4V-3-6C-M-KUP5-GL7-60- P23-EN214, DG4V36CMKUP5GL760
Danfoss
833AN00349A

DG4V-3-6C-M-KUP5-GL7-60- P23-EN214, DG4V36CMKUP5GL760

Danfoss 833AN00344A – DG4V-3-2A-M-FW-D8-60, DG4V32AMFWD860
Danfoss
833AN00344A

DG4V-3-2A-M-FW-D8-60, DG4V32AMFWD860

Danfoss 833AN00343A – DG4V-3-6C-M-FW-D8-60, DG4V36CMFWD860
Danfoss
833AN00343A

DG4V-3-6C-M-FW-D8-60, DG4V36CMFWD860

Danfoss 833AN00326A – DG4V-3-0B-H-VM-KUP5-H7-60, DG4V30BHVMKUP5H760
Danfoss
833AN00326A

DG4V-3-0B-H-VM-KUP5-H7-60, DG4V30BHVMKUP5H760

Danfoss 833AN00325A – DG4V-3-6C-H-VM-KUP5-H7-60, DG4V36CHVMKUP5H760
Danfoss
833AN00325A

DG4V-3-6C-H-VM-KUP5-H7-60, DG4V36CHVMKUP5H760

Danfoss 833AN00323A – DG4V-3-0C-M-U-B8-60, DG4V30CMUB860
Danfoss
833AN00323A

DG4V-3-0C-M-U-B8-60, DG4V30CMUB860

Danfoss 833AN00319A – DG4V-3-2N-M-U-D8-60, DG4V32NMUD860
Danfoss
833AN00319A

DG4V-3-2N-M-U-D8-60, DG4V32NMUD860

Danfoss 833AN00318A – DG4V-3-2AL-M-U-D8-60, DG4V32ALMUD860
Danfoss
833AN00318A

DG4V-3-2AL-M-U-D8-60, DG4V32ALMUD860

Danfoss 833AN00315A – DG4V-3-0C-M-U-D8-60, DG4V30CMUD860
Danfoss
833AN00315A

DG4V-3-0C-M-U-D8-60, DG4V30CMUD860

Danfoss 833AN00314A – DG4V-3-2A-VM-S7-U-A6-60, DG4V32AVMS7UA660
Danfoss
833AN00314A

DG4V-3-2A-VM-S7-U-A6-60, DG4V32AVMS7UA660

Danfoss 833AN00312A – DG4V-3-2AL-M-U-A8-60, DG4V32ALMUA860
Danfoss
833AN00312A

DG4V-3-2AL-M-U-A8-60, DG4V32ALMUA860

Danfoss 833AN00310A – DG4V-3-8C-VM-U-D8-61, DG4V38CVMUD861
Danfoss
833AN00310A

DG4V-3-8C-VM-U-D8-61, DG4V38CVMUD861

Danfoss 833AN00296A – DG4V-3-0C-M-U-C8-60, DG4V30CMUC860
Danfoss
833AN00296A

DG4V-3-0C-M-U-C8-60, DG4V30CMUC860

Danfoss 833AN00293A – DG4V-3-2C-M-U-D8-60, DG4V32CMUD860
Danfoss
833AN00293A

DG4V-3-2C-M-U-D8-60, DG4V32CMUD860

Danfoss 833AN00292A – DG4V-3-2A-M-U-B8-60, DG4V32AMUB860
Danfoss
833AN00292A

DG4V-3-2A-M-U-B8-60, DG4V32AMUB860

Compare Manifold directional control valves

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNCoil RatingModel Code 1Power ConsumptionSolenoid Energising IDSpring Arrangement
843AN00012A24 VDCDG4V32N208VMUHH76036 wattSol A port A/Sol B port BNo spring detented
843AN00010A24 VDCDG4V36C208VMUHH76036 wattSol A port A/Sol B port BSpring centred
843AN00009A24 VDCDG4V38C208VMUHH76036 wattSol A port A/Sol B port BSpring centred
843AN00008A24 VDCDG4V30C208VMUHH76036 wattSol A port A/Sol B port BSpring centred
833AN00391A110 VAC 50Hz/120 VAC 60HzDG4V36CMFPA5WLB86061VA 50HZ - 58VA 60HZStandard as per ANSI B93 9Spring centred
833AN00371A110 VAC 50Hz/120 VAC 60HzDG4V30CMFWB86061VA 50HZ - 58VA 60HZStandard as per ANSI B93 9Spring centred
833AN00361A110 VAC 50Hz/120 VAC 60HzDG4V36CMFWB86061VA 50HZ - 58VA 60HZStandard as per ANSI B93 9Spring centred
833AN00360A110 VAC 50Hz/120 VAC 60HzDG4V36CMFTWLB86061VA 50HZ - 58VA 60HZStandard as per ANSI B93 9Spring centred
833AN00350A12 VDCDG4V36CMUG760P2030 wattStandard as per ANSI B93 9Spring centred
833AN00349A12 VDCDG4V36CMKUP5GL76018 wattStandard as per ANSI B93 9Spring centred
833AN00344A220 VAC 50 Hz/240 VAC 60 HzDG4V32AMFWD86061VA 50HZ - 58VA 60HZStandard as per ANSI B93 9Spring offset end to end
833AN00343A220 VAC 50 Hz/240 VAC 60 HzDG4V36CMFWD86061VA 50HZ - 58VA 60HZStandard as per ANSI B93 9Spring centred
833AN00326A24 VDCDG4V30BHVMKUP5H76030 wattSolenoid B at port B endSpring offset end to centre
833AN00325A24 VDCDG4V36CHVMKUP5H76030 wattSol A port A/Sol B port BSpring centred
833AN00323A110 VAC 50Hz/120 VAC 60HzDG4V30CMUB86061VA 50HZ - 58VA 60HZStandard as per ANSI B93 9Spring centred
833AN00319A220 VAC 50 Hz/240 VAC 60 HzDG4V32NMUD86061VA 50HZ - 58VA 60HZStandard as per ANSI B93 9No spring detented
833AN00318A220 VAC 50 Hz/240 VAC 60 HzDG4V32ALMUD86061VA 50HZ - 58VA 60HZStandard as per ANSI B93 9Spring offset end to end LH
833AN00315A220 VAC 50 Hz/240 VAC 60 HzDG4V30CMUD86061VA 50HZ - 58VA 60HZStandard as per ANSI B93 9Spring centred
833AN00314A110 VAC 50HzDG4V32AVMS7UA66054 VASolenoid A at port A endSpring offset end to end
833AN00312A110 VAC 50HzDG4V32ALMUA86054 VAStandard as per ANSI B93 9Spring offset end to end LH
833AN00310A220 VAC 50 Hz/240 VAC 60 HzDG4V38CVMUD86161VA 50HZ - 58VA 60HZSol A port A/Sol B port BSpring centred
833AN00296A220 VAC 50HzDG4V30CMUC86054 VAStandard as per ANSI B93 9Spring centred
833AN00293A220 VAC 50 Hz/240 VAC 60 HzDG4V32CMUD86061VA 50HZ - 58VA 60HZStandard as per ANSI B93 9Spring centred
833AN00292A110 VAC 50Hz/120 VAC 60HzDG4V32AMUB86061VA 50HZ - 58VA 60HZStandard as per ANSI B93 9Spring offset end to end

Common to all listed parts

Actuation TypeSolenoid operated
Design Series60 Series
Flow rate upto GPM21.0
Flow rate upto LPM80.0
Fluid Cleanliness19/17/14 micron
Fluid compatibilityPetroleum oils
InterfaceISO4401-03
PerformanceHigh performance