Wall mounting Parts






Compare Wall mounting
Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.
| MPN | Installed load | Inrush current | Accuracy of the safe current – SIL 2 / PL d / Cat. 2 | Reduction of continuous current depending on installation elevation – Starting at 500 m above sea level | Peak current per motor connection |
|---|---|---|---|---|---|
| 8EI2X2HWTS0.XXXX-1 | Max. 7.5 kVA | Max. 45 A | 0.555 A | 0.22 A eff per 1000 m | 6 / 6 / 6 A eff |
| 8EI2X2MWTS0.XXXX-1 | Max. 3.75 kVA | Max. 22 A | 0.555 A | 0.22 A eff per 1000 m | 6 / 6 / 6 A eff |
| 8EI4X5HWTS0.XXXX-1 | Max. 10 kVA | Max. 45 A | 0.688 A | 0.45 A eff per 1000 m | 12.25 / 12.25 / 12.25 A eff |
| 8EI4X5MWTS0.XXXX-1 | Max. 5 kVA | Max. 22 A | 0.688 A | 0.45 A eff per 1000 m | 12.25 / 12.25 / 12.25 A eff |
| 8EI8X8HWTS0.XXXX-1 | Max. 10 kVA | Max. 45 A | 0.936 A | 0.88 A eff per 1000 m | 24 / 24 / 24 A eff |
| 8EI8X8MWTS0.XXXX-1 | Max. 5 kVA | Max. 22 A | 0.936 A | 0.88 A eff per 1000 m | 24 / 24 / 24 A eff |
Common to all listed parts
| Support – Dynamic node allocation (DNA) | Yes |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| Certifications – UL | cULus E225616; Power conversion equipment |
| Certifications – KC | Yes |
| Slots for plug-in modules | 1 |
| Terminal connection cross section – With wire end sleeve | 0.25 to 4 mm² |