ACH580 Parts

Showing 97–120 of 794 parts
ABB ACH580-VCR-046A-2 – HVAC drive with vertical e-clipse bypass and circuit breaker disconnect US, UL: Pld 15 Hp, 46.2 A, 230 V ( )
ABB
ACH580-VCR-046A-2

HVAC drive with vertical e-clipse bypass and circuit…

ABB ACH580-VCR-04A6-2 – HVAC drive with vertical e-clipse bypass and circuit breaker disconnect US, UL: Pld 1 Hp, 4.6 A, 230 V ( )
ABB
ACH580-VCR-04A6-2

HVAC drive with vertical e-clipse bypass and circuit…

ABB ACH580-BDR-059A-2 – HVAC packaged drive with e-clipse bypass and disconnect US, UL: Pld 20 Hp, 59.4 A, 230 V ( )
ABB
ACH580-BDR-059A-2

HVAC packaged drive with e-clipse bypass and disconnect US

ABB ACH531-01-12A7-4 – LV AC wall-mounted drive for HVAC, IEC: Pn 5.5 kW, 12.6 A ( )
ABB
ACH531-01-12A7-4

LV AC wall-mounted drive for HVAC, IEC: Pn 5.5 kW

ABB ACH580-BDR-156A-4 – HVAC packaged drive with e-clipse bypass and disconnect US, UL: Pld 125 Hp, 156 A, 460 V ( )
ABB
ACH580-BDR-156A-4

HVAC packaged drive with e-clipse bypass and disconnect US

ABB ACH580-BCR-096A-4 – HVAC packaged drive with e-clipse bypass and circuit breaker disconnect US, UL: Pld 75 Hp, 96 A, 460 V ( )
ABB
ACH580-BCR-096A-4

HVAC packaged drive with e-clipse bypass and circuit…

ABB ACH580-BDR-124A-4 – HVAC packaged drive with e-clipse bypass and disconnect US, UL: Pld 100 Hp, 124 A, 460 V ( )
ABB
ACH580-BDR-124A-4

HVAC packaged drive with e-clipse bypass and disconnect US

ABB ACH180-04S-02A4-1 – LV AC micro drive module for HVAC, IEC: Pn 0.37 kW, 2.4 A, 230 V, UL: Pld 0.5 Hp, 2.4 A, 230 V ( )
ABB
ACH180-04S-02A4-1

LV AC micro drive module for HVAC, IEC: Pn 0.37 kW, 2.4 A

ABB ACH180-04S-033A-2 – LV AC micro drive module for HVAC, IEC: Pn 7.5 kW, 32.0 A, 230 V, UL: Pld 10 Hp, 30.8 A, 208 V ( )
ABB
ACH180-04S-033A-2

LV AC micro drive module for HVAC, IEC: Pn 7.5 kW, 32.0 A

ABB ACH580-3PDR-052A-4 – HVAC packaged ultra-low harmonic drive with non-fused disconnect, UL: Pld 40 Hp, 52 A, 460 V ( )
ABB
ACH580-3PDR-052A-4

HVAC packaged ultra-low harmonic drive with non-fused…

ABB ACH580-BDR-099A-6 – HVAC packaged drive with e-clipse bypass and disconnect US, UL: Pld 100 Hp, 99 A, 575 V ( )
ABB
ACH580-BDR-099A-6

HVAC packaged drive with e-clipse bypass and disconnect US

ABB ACH580-BDR-125A-6 – HVAC packaged drive with e-clipse bypass and disconnect US, UL: Pld 125 Hp, 125 A, 575 V ( )
ABB
ACH580-BDR-125A-6

HVAC packaged drive with e-clipse bypass and disconnect US

ABB ACH580-3PDR-077A-4 – HVAC packaged ultra-low harmonic drive with non-fused disconnect, UL: Pld 60 Hp, 77 A, 460 V ( )
ABB
ACH580-3PDR-077A-4

HVAC packaged ultra-low harmonic drive with non-fused…

ABB ACH580-3BCR-302A-4 – HVAC Enclosed ultra-low harmonic drive with circuit breaker, UL: Pld 250 Hp, 302 A, 460 V ( )
ABB
ACH580-3BCR-302A-4

HVAC Enclosed ultra-low harmonic drive with circuit breaker

ABB ACH580-3BDR-302A-4 – HVAC Enclosed ultra-low harmonic drive with non-fused disconnect, UL: Pld 250 Hp, 302 A, 460 V ( )
ABB
ACH580-3BDR-302A-4

HVAC Enclosed ultra-low harmonic drive with non-fused…

ABB ACH580-3BDR-240A-4 – HVAC Enclosed ultra-low harmonic drive with non-fused disconnect, UL: Pld 200 Hp, 240 A, 460 V ( )
ABB
ACH580-3BDR-240A-4

HVAC Enclosed ultra-low harmonic drive with non-fused…

ABB ACH580-3BCR-361A-4 – HVAC Enclosed ultra-low harmonic drive with circuit breaker, UL: Pld 300 Hp, 361 A, 460 V ( )
ABB
ACH580-3BCR-361A-4

HVAC Enclosed ultra-low harmonic drive with circuit breaker

Compare ACH580

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNProduct Net WeightProduct Net Depth / LengthProduct Net HeightOutput Current, Light-Overload Use (UL)Output Power, Light-Overload Use (UL)
ACH580-VCR-046A-286 lb12 in56.82 in46.2 A A15 Hp
ACH580-VCR-04A6-230 lb10.55 in40.18 in4.6 A A1 Hp
ACH580-BDR-059A-2139 lb15.3 in40.6 in59.4 A A20 Hp
ACH531-01-12A7-44 kg kg223 mm mm331 mm mm——
ACH531-01-05A6-4+J4001.6 kg kg207 mm mm223 mm mm——
ACH531-01-04A0-4+J4001.6 kg kg207 mm mm223 mm mm——
ACH531-01-02A6-4+J4001.6 kg kg207 mm mm223 mm mm——
ACH580-BDR-156A-4390 lb19.04 in47.72 in156 A A125 Hp
ACH580-BCR-096A-4390 lb19.04 in47.72 in96 A A75 Hp
ACH580-BDR-124A-4390 lb19.04 in47.72 in124 A A100 Hp
ACH180-04S-02A4-10.92 kg, 2.03 lb kg143 mm, 5.630 in mm209 mm, 8.228 in mm2.4 A A0.5 Hp
ACH180-04S-033A-23.30 kg, 7.28 lb kg174 mm, 6.850 in mm241 mm, 9.488 in mm30.8 A A10 Hp
ACH580-3PDR-052A-4200 lb18.8 in51 in52 A A40 Hp
ACH580-BDR-099A-6390 lb19.04 in47.72 in99 A A100 Hp
ACH580-BDR-125A-6390 lb19.04 in47.72 in125 A A125 Hp
ACH580-PCR-143A-2+B0560 kg kg——143 A A50 Hp
ACH580-PCR-088A-2+B0560 kg kg——88 A A30 Hp
ACH580-BCR-017A-2+B0580 kg kg——16.7 A A5 Hp
ACH580-3PDR-077A-4200 lb18.8 in51 in77 A A60 Hp
ACH580-PDR-059A-2+B0580 kg kg——59.4 A A20 Hp
ACH580-3BCR-302A-41690 lb25 in90 in302 A A250 Hp
ACH580-3BDR-302A-41690 lb25 in90 in302 A A250 Hp
ACH580-3BDR-240A-41690 lb25 in90 in240 A A200 Hp
ACH580-3BCR-361A-41690 lb25 in90 in361 A A300 Hp

Common to all listed parts

Minimum Order Quantity1 piece
Order Multiple1 piece
Quote OnlyNo