Flush mountable for hydrostatic level measurement Parts
Compare Flush mountable for hydrostatic level measurement
Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.
| MPN | Measuring range | Pressure rating | Set point SP | Analogue start point | Analogue end point |
|---|---|---|---|---|---|
| PG1708 | -12.4...250 mbar; -0.18...3.626 psi | 6000 mbar; 87 psi | -12.4...250 mbar; -0.18...3.626 psi | -12.4...200 bar; -0.18...2.901 psi | 37.6...250 mbar; 0.545...3.626 psi |
| PG1706 | -0.124...2.5 bar; -1.8...36.26 psi | 20 bar; 290 psi | -0.124...2.5 bar; -1.8...36.26 psi | -0.124...2 bar; -1.8...29.01 psi | 0.376...2.5 bar; 5.45...36.26 psi |
| PG1707 | -50...1000 mbar; -0.73...14.5 psi | 10000 mbar; 145 psi | -50...1000 mbar; -0.73...14.5 psi | -50...800 mbar; -0.73...11.6 psi | 150...1000 mbar; 2.18...14.5 psi |
| PG1717 | -0.1...1.6 bar; -1.45...23.21 psi | 15 bar; 217 psi | -0.1...1.6 bar; -1.45...23.21 psi | -0.1...1.28 bar; -1.45...18.56 psi | 0.22...1.6 bar; 3.19...23.21 psi |
Common to all listed parts
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Process connection | threaded connection G 1 external thread Aseptoflex Vario |
| Special feature | Gold-plated contacts |
| Measuring element | ceramic-capacitive pressure measuring cell |
| Application | flush mountable for the food and beverage industry |
| Media | viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature[°C] [°C] | -25...150 |
| Vacuum resistance | -1000 mbar; 14.5 psi |