| 83101157 | 65cc/rev max/variable displacement | Left hand - counter clockwise | ISO 3019 125-4 (U) | 40 kW power control setting @ 1500 rpm | 25 bar load sensing control setting |
| 83101156 | 65cc/rev max/variable displacement | Left hand - counter clockwise | ISO 3019 125-4 (U) | 40 kW power control setting @ 1500 rpm | No load sensing control |
| 83101155 | 193cc/rev max/variable displacement | Right hand - clockwise | SAE J744 165-4 (E) | No power control | No load sensing control |
| 83101128 | 145cc/rev max/variable displacement | Left hand - counter clockwise | SAE J744 152-4 (D) | No power control | 20 bar load sensing control setting |
| 83101106 | 193cc/rev max/variable displacement | Left hand - counter clockwise | SAE J744 165-4 (E) | 70 kW power control setting @ 1500 rpm | No load sensing control |
| 83101100 | 193cc/rev max/variable displacement | Right hand - clockwise | SAE J744 165-4 (E) | 55 kW power control setting @ 1500 rpm | 25 bar load sensing control setting |
| 83101097 | 260cc/rev max/variable displacement | Right hand - clockwise | SAE J744 165-4 (E) | 100 kW power control setting @ 1500 rpm | 25 bar load sensing control setting |
| 83101066 | 260cc/rev max/variable displacement | Right hand - clockwise | SAE J744 165-4 (E) | 100 kW power control setting @ 1500 rpm | 25 bar load sensing control setting |
| 83101065 | 193cc/rev max/variable displacement | Left hand - counter clockwise | SAE J744 165-4 (E) | 80 kW power control setting @ 1500 rpm | 25 bar load sensing control setting |
| 83101064 | 193cc/rev max/variable displacement | Left hand - counter clockwise | SAE J744 165-4 (E) | 80 kW power control setting @ 1500 rpm | 25 bar load sensing control setting |
| 83101028 | 193cc/rev max/variable displacement | Left hand - counter clockwise | SAE J744 165-4 (E) | No power control | 30 bar load sensing control setting |
| 83100999 | 145cc/rev max/variable displacement | Right hand - clockwise | SAE J744 152-4 (D) | 60 kW power control setting @ 1500 rpm | 20 bar load sensing control setting |
| 83100963 | 145cc/rev max/variable displacement | Right hand - clockwise | SAE J744 152-4 (D) | No power control | 30 bar load sensing control setting |
| 83100952 | 130cc/rev max/variable displacement | Left hand - counter clockwise | SAE J744 152-4 (D) | 60 kW power control setting @ 1500 rpm | 20 bar load sensing control setting |
| 83100944 | 193cc/rev max/variable displacement | Right hand - clockwise | SAE J744 165-4 (E) | 90 kW power control setting @ 1500 rpm | No load sensing control |
| 83100943 | 145cc/rev max/variable displacement | Right hand - clockwise | SAE J744 152-4 (D) | 75 kW power control setting @ 1500 rpm | No load sensing control |
| 83100926 | 130cc/rev max/variable displacement | Right hand - clockwise | SAE J744 152-4 (D) | 60 kW power control setting @ 1500 rpm | 20 bar load sensing control setting |
| 83100897 | 193cc/rev max/variable displacement | Right hand - clockwise | SAE J744 165-4 (E) | No power control | 30 bar load sensing control setting |
| 83100644 | 193cc/rev max/variable displacement | Right hand - clockwise | SAE J744 165-4 (E) | No power control | 20 bar load sensing control setting |
| 83100623 | 260cc/rev max/variable displacement | Left hand - counter clockwise | SAE J744 165-4 (E) | No power control | 25 bar load sensing control setting |
| 83100562 | 260cc/rev max/variable displacement | Right hand - clockwise | SAE J744 165-4 (E) | No power control | No load sensing control |
| 83100515 | 145cc/rev max/variable displacement | Left hand - counter clockwise | SAE J744 152-4 (D) | No power control | 24 bar load sensing control setting |
| 83100438 | 130cc/rev max/variable displacement | Left hand - counter clockwise | SAE J744 152-4 (D) | No power control | 16 bar load sensing control setting |
| 83100396 | 145cc/rev max/variable displacement | Right hand - clockwise | SAE J744 152-4 (D) | 25 kW power control setting @ 1500 rpm | No load sensing control |