D1P open-circuit high-power axial piston pumps Parts

Showing 745–768 of 2,693 parts
Danfoss 83124652 – PUMP-VAR DISPL, D1P193
Danfoss
83124652

PUMP-VAR DISPL, D1P193

Danfoss 83124618 – PUMP-VAR DISPL, D1P130
Danfoss
83124618

PUMP-VAR DISPL, D1P130

Danfoss 83124584 – PUMP-VAR DISPL, D1P145
Danfoss
83124584

PUMP-VAR DISPL, D1P145

Danfoss 83124578 – PUMP-VAR DISPL, D1P145
Danfoss
83124578

PUMP-VAR DISPL, D1P145

Danfoss 83124577 – PUMP-VAR DISPL, D1P130
Danfoss
83124577

PUMP-VAR DISPL, D1P130

Danfoss 83124560 – PUMP-VAR DISPL, D1P065
Danfoss
83124560

PUMP-VAR DISPL, D1P065

Danfoss 83124558 – PUMP-VAR DISPL, D1P260
Danfoss
83124558

PUMP-VAR DISPL, D1P260

Danfoss 83124557 – PUMP-VAR DISPL, D1P260
Danfoss
83124557

PUMP-VAR DISPL, D1P260

Danfoss 83124469 – PUMP-VAR DISPL, D1P065
Danfoss
83124469

PUMP-VAR DISPL, D1P065

Danfoss 83124288 – PUMP-VAR DISPL, D1P065
Danfoss
83124288

PUMP-VAR DISPL, D1P065

Danfoss 83124287 – PUMP-VAR DISPL, D1P145
Danfoss
83124287

PUMP-VAR DISPL, D1P145

Danfoss 83124244 – PUMP-VAR DISPL, D1P145
Danfoss
83124244

PUMP-VAR DISPL, D1P145

Danfoss 83124243 – PUMP-VAR DISPL, D1P193
Danfoss
83124243

PUMP-VAR DISPL, D1P193

Danfoss 83124242 – PUMP-VAR DISPL, D1P260
Danfoss
83124242

PUMP-VAR DISPL, D1P260

Danfoss 83124174 – PUMP-VAR DISPL, D1P145
Danfoss
83124174

PUMP-VAR DISPL, D1P145

Danfoss 83124173 – PUMP-VAR DISPL, D1P145
Danfoss
83124173

PUMP-VAR DISPL, D1P145

Danfoss 83124172 – PUMP-VAR DISPL, D1P145
Danfoss
83124172

PUMP-VAR DISPL, D1P145

Danfoss 83124167 – PUMP-VAR DISPL, D1P160
Danfoss
83124167

PUMP-VAR DISPL, D1P160

Danfoss 83124166 – PUMP-VAR DISPL, D1P193
Danfoss
83124166

PUMP-VAR DISPL, D1P193

Danfoss 83124164 – PUMP-VAR DISPL, D1P130
Danfoss
83124164

PUMP-VAR DISPL, D1P130

Danfoss 83124147 – PUMP-VAR DISPL, D1P193
Danfoss
83124147

PUMP-VAR DISPL, D1P193

Danfoss 83124105 – PUMP-VAR DISPL, D1P193
Danfoss
83124105

PUMP-VAR DISPL, D1P193

Danfoss 83124055 – PUMP-VAR DISPL, D1P145
Danfoss
83124055

PUMP-VAR DISPL, D1P145

Danfoss 83124054 – PUMP-VAR DISPL, D1P145
Danfoss
83124054

PUMP-VAR DISPL, D1P145

Compare D1P open-circuit high-power axial piston pumps

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNDisplacementRotationFront mounting flangePower control settingLoad sense setting
83124652193cc/rev max/variable displacementRight hand - clockwiseSAE J744 165-4 (E)100 kW power control setting @ 1500 rpmNo load sensing control
83124618130cc/rev max/variable displacementLeft hand - counter clockwiseSAE J744 152-4 (D)No power control20 bar load sensing control setting
83124584145cc/rev max/variable displacementRight hand - clockwiseSAE J744 152-4 (D)No power control20 bar load sensing control setting
83124578145cc/rev max/variable displacementRight hand - clockwiseSAE J744 152-4 (D)No power control20 bar load sensing control setting
83124577130cc/rev max/variable displacementRight hand - clockwiseSAE J744 152-4 (D)No power control20 bar load sensing control setting
8312456065cc/rev max/variable displacementLeft hand - counter clockwiseSAE J744 127-4 (C)45 kW power control setting @ 1500 rpm25 bar load sensing control setting
83124558260cc/rev max/variable displacementLeft hand - counter clockwiseSAE J744 165-4 (E)145 kW power control setting @ 1500 rpm22 bar load sensing control setting
83124557260cc/rev max/variable displacementLeft hand - counter clockwiseSAE J744 165-4 (E)145 kW power control setting @ 1500 rpm22 bar load sensing control setting
8312446965cc/rev max/variable displacementLeft hand - counter clockwiseISO 3019 125-4 (U)40 kW power control setting @ 1500 rpm25 bar load sensing control setting
8312428865cc/rev max/variable displacementRight hand - clockwiseSAE J744 127-4 (C)55 kW power control setting @ 1500 rpm20 bar load sensing control setting
83124287145cc/rev max/variable displacementRight hand - clockwiseSAE J744 152-4 (D)60 kW power control setting @ 1500 rpm35 bar load sensing control setting
83124244145cc/rev max/variable displacementRight hand - clockwiseSAE J744 152-4 (D)No power control28 bar load sensing control setting
83124243193cc/rev max/variable displacementRight hand - clockwiseSAE J744 165-4 (E)No power control30 bar load sensing control setting
83124242260cc/rev max/variable displacementRight hand - clockwiseSAE J744 165-4 (E)80 kW power control setting @ 1500 rpm25 bar load sensing control setting
83124174145cc/rev max/variable displacementRight hand - clockwiseSAE J744 152-4 (D)50 kW power control setting @ 1500 rpm20 bar load sensing control setting
83124173145cc/rev max/variable displacementRight hand - clockwiseSAE J744 152-4 (D)50 kW power control setting @ 1500 rpm20 bar load sensing control setting
83124172145cc/rev max/variable displacementRight hand - clockwiseSAE J744 152-4 (D)65 kW power control setting @ 1500 rpm20 bar load sensing control setting
83124167160cc/rev max/variable displacementRight hand - clockwiseSAE J744 152-4 (D)No power control30 bar load sensing control setting
83124166193cc/rev max/variable displacementRight hand - clockwiseSAE J744 165-4 (E)140 kW power control setting @ 1500 rpm20 bar load sensing control setting
83124164130cc/rev max/variable displacementRight hand - clockwiseSAE J744 152-4 (D)60 kW power control setting @ 1500 rpmNo load sensing control
83124147193cc/rev max/variable displacementRight hand - clockwiseSAE J744 165-4 (E)100 kW power control setting @ 1500 rpm25 bar load sensing control setting
83124105193cc/rev max/variable displacementRight hand - clockwiseSAE J744 165-4 (E)No power control20 bar load sensing control setting
83124055145cc/rev max/variable displacementRight hand - clockwiseSAE J744 152-4 (D)No power control25 bar load sensing control setting
83124054145cc/rev max/variable displacementRight hand - clockwiseSAE J744 152-4 (D)No power control25 bar load sensing control setting

Common to all listed parts

D1P ProductD1P variable axial piston pump
Product versionProduct version A
Hydraulic displacement control start pressure settingNo hydraulic displacement control
Maximum displacement setting100% of maximum displacement
Minimum displacement setting0% of displacement
Special hardwareNo special hardware
Proposition 65Cancer and Reproductive Harm