D1P open-circuit high-power axial piston pumps Parts

Showing 649–672 of 2,693 parts
Danfoss 83128199 – PUMP-VAR DISPL, D1P193
Danfoss
83128199

PUMP-VAR DISPL, D1P193

Danfoss 83128171 – PUMP-VAR DISPL, D1P193
Danfoss
83128171

PUMP-VAR DISPL, D1P193

Danfoss 83128169 – PUMP-VAR DISPL, D1P193
Danfoss
83128169

PUMP-VAR DISPL, D1P193

Danfoss 83128142 – PUMP-VAR DISPL, D1P145
Danfoss
83128142

PUMP-VAR DISPL, D1P145

Danfoss 83128022 – PUMP-VAR DISPL, D1P130
Danfoss
83128022

PUMP-VAR DISPL, D1P130

Danfoss 83128020 – PUMP-VAR DISPL, D1P130
Danfoss
83128020

PUMP-VAR DISPL, D1P130

Danfoss 83128006 – PUMP-VAR DISPL, D1P193
Danfoss
83128006

PUMP-VAR DISPL, D1P193

Danfoss 83127975 – PUMP-VAR DISPL, D1P160
Danfoss
83127975

PUMP-VAR DISPL, D1P160

Danfoss 83127890 – PUMP-VAR DISPL, D1P193
Danfoss
83127890

PUMP-VAR DISPL, D1P193

Danfoss 83127885 – PUMP-VAR DISPL, D1P193
Danfoss
83127885

PUMP-VAR DISPL, D1P193

Danfoss 83127884 – PUMP-VAR DISPL, D1P065
Danfoss
83127884

PUMP-VAR DISPL, D1P065

Danfoss 83127883 – PUMP-VAR DISPL, D1P260
Danfoss
83127883

PUMP-VAR DISPL, D1P260

Danfoss 83127882 – PUMP-VAR DISPL, D1P193
Danfoss
83127882

PUMP-VAR DISPL, D1P193

Danfoss 83127861 – PUMP-VAR DISPL, D1P260
Danfoss
83127861

PUMP-VAR DISPL, D1P260

Danfoss 83127750 – PUMP-VAR DISPL, D1P260
Danfoss
83127750

PUMP-VAR DISPL, D1P260

Danfoss 83127697 – PUMP-VAR DISPL, D1P130
Danfoss
83127697

PUMP-VAR DISPL, D1P130

Danfoss 83127607 – PUMP-VAR DISPL, D1P145
Danfoss
83127607

PUMP-VAR DISPL, D1P145

Danfoss 83127605 – PUMP-VAR DISPL, D1P145
Danfoss
83127605

PUMP-VAR DISPL, D1P145

Danfoss 83127604 – PUMP-VAR DISPL, D1P145
Danfoss
83127604

PUMP-VAR DISPL, D1P145

Danfoss 83127572 – PUMP-VAR DISPL, D1P193
Danfoss
83127572

PUMP-VAR DISPL, D1P193

Danfoss 83127551 – PUMP-VAR DISPL, D1P193
Danfoss
83127551

PUMP-VAR DISPL, D1P193

Danfoss 83127504 – PUMP-VAR DISPL, D1P193
Danfoss
83127504

PUMP-VAR DISPL, D1P193

Danfoss 83127464 – PUMP-VAR DISPL, D1P260
Danfoss
83127464

PUMP-VAR DISPL, D1P260

Danfoss 83127440 – PUMP-VAR DISPL, D1P145
Danfoss
83127440

PUMP-VAR DISPL, D1P145

Compare D1P open-circuit high-power axial piston pumps

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNDisplacementFront mounting flangePower control settingLoad sense settingMaximum displacement setting
83128199193cc/rev max/variable displacementSAE J744 165-4 (E)100 kW power control setting @ 1500 rpmNo load sensing control100% of maximum displacement
83128171193cc/rev max/variable displacementSAE J744 165-4 (E)No power control20 bar load sensing control setting100% of maximum displacement
83128169193cc/rev max/variable displacementSAE J744 165-4 (E)No power control20 bar load sensing control setting100% of maximum displacement
83128142145cc/rev max/variable displacementSAE J744 152-4 (D)55 kW power control setting @ 1500 rpm24 bar load sensing control setting100% of maximum displacement
83128022130cc/rev max/variable displacementSAE J744 152-4 (D)No power control20 bar load sensing control setting100% of maximum displacement
83128020130cc/rev max/variable displacementSAE J744 152-4 (D)45 kW power control setting @ 1500 rpmNo load sensing control80% of displacement
83128006193cc/rev max/variable displacementSAE J744 165-4 (E)60 kW power control setting @ 1500 rpm19 bar load sensing control setting93% of displacement
83127975160cc/rev max/variable displacementSAE J744 152-4 (D)No power control25 bar load sensing control setting100% of maximum displacement
83127890193cc/rev max/variable displacementSAE J744 165-4 (E)80 kW power control setting @ 1500 rpm20 bar load sensing control setting93% of displacement
83127885193cc/rev max/variable displacementSAE J744 165-4 (E)110 kW power control setting @ 1500 rpm25 bar load sensing control setting100% of maximum displacement
8312788465cc/rev max/variable displacementSAE J744 127-4 (C)No power control20 bar load sensing control setting100% of maximum displacement
83127883260cc/rev max/variable displacementSAE J744 165-4 (E)100 kW power control setting @ 1500 rpmNo load sensing control100% of maximum displacement
83127882193cc/rev max/variable displacementSAE J744 165-4 (E)100 kW power control setting @ 1500 rpmNo load sensing control100% of maximum displacement
83127861260cc/rev max/variable displacementSAE J744 165-4 (E)100 kW power control setting @ 1500 rpmNo load sensing control100% of maximum displacement
83127750260cc/rev max/variable displacementSAE J744 165-4 (E)No power control25 bar load sensing control setting100% of maximum displacement
83127697130cc/rev max/variable displacementSAE J744 152-4 (D)No power control15 bar load sensing control setting100% of maximum displacement
83127607145cc/rev max/variable displacementSAE J744 152-4 (D)30 kW power control setting @ 1500 rpm25 bar load sensing control setting100% of maximum displacement
83127605145cc/rev max/variable displacementSAE J744 152-4 (D)70 kW power control setting @ 1500 rpm20 bar load sensing control setting100% of maximum displacement
83127604145cc/rev max/variable displacementSAE J744 152-4 (D)70 kW power control setting @ 1500 rpm20 bar load sensing control setting100% of maximum displacement
83127572193cc/rev max/variable displacementSAE J744 165-4 (E)70 kW power control setting @ 1500 rpm22 bar load sensing control setting100% of maximum displacement
83127551193cc/rev max/variable displacementSAE J744 165-4 (E)65 kW power control setting @ 1500 rpm20 bar load sensing control setting100% of maximum displacement
83127504193cc/rev max/variable displacementSAE J744 165-4 (E)140 kW power control setting @ 1500 rpm20 bar load sensing control setting100% of maximum displacement
83127464260cc/rev max/variable displacementSAE J744 165-4 (E)120 kW power control setting @ 1500 rpm25 bar load sensing control setting100% of maximum displacement
83127440145cc/rev max/variable displacementSAE J744 152-4 (D)80 kW power control setting @ 1500 rpm25 bar load sensing control setting100% of maximum displacement

Common to all listed parts

D1P ProductD1P variable axial piston pump
Product versionProduct version A
Hydraulic displacement control start pressure settingNo hydraulic displacement control
Minimum displacement setting0% of displacement
Special hardwareNo special hardware
Proposition 65Cancer and Reproductive Harm