产品概览
| 库存情况 | 需按需确认 |
| 分类 | Multi-function |
| 生命周期状态 | active |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
| 重量 | 200 kg |
发货与库存
X67DC1198 何时可以发货?
X67DC1198 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 X67DC1198 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 X67DC1198 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 X67DC1198 安排当日快递或专车加急配送。
2 incremental or SSI encoder inputs 5 V2 digital channels, 24 V per connection, configurable either as inputs or outputs4 AB counters on the digital inputsPulse width modulation of the digital outputsEncoder power supply 5 V and 24 V integrated in encoder connection The possibilities are almost endless with this digital counter module. Connectors 1 and 3 are 12-pin M12 connectors. Each of these can be used to connect 1 incremental encoder or SSI encoder with 5 V differential signals. In addition, there are 2 digital channels available on the same output which, when configured as inputs, can be used with incremental encoders with status outputs (e.g. alarms). When configured as outputs, they act as preset and count direction switching functions when used together with SSI encoders, for example.2 more sockets and 2 more configurable digital channels are available on female connectors 2 and 4. The inputs can be used as latch, gate, or home enable switches, while the outputs can be used as comparator outputs, for example.
技术规格
Specifications
| I/O module | 2 SSI absolute encoders 5 V or 2 ABR incremental encoders 5 V, 4 AB counters or 4 up/down counters 24 V, 2x pulse width modulation, time measurement, relative timestamp |
| Insulation voltage between encoder and bus | 500 Veff |
| B&R ID code | 0x18D0 |
| Sensor/Actuator power supply | Max. 12 W |
| Status indicators | I/O function per channel, supply voltage, bus function |
| Outputs | Yes, using LED status indicator and software |
| I/O power supply | M8, 4-pin |
| X2X Link | M12, B-coded |
| Inputs/Outputs | 2x M12, 5-pin, A-coded |
| SSI/ABR encoder | 2x M12, 12-pin, A-coded |
| Internal I/O | 2.8 W |
| X2X Link power supply | 0.75 W |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX | Zone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 - Max. 60°C TÜV 05 ATEX 7201X |
| UL | cULus E115267 Industrial control equipment |
| HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| KC | Yes |
| Nominal voltage | 24 VDC |
| Voltage range | 18 to 30 VDC |
| Integrated protective function | Reverse polarity protection |
| Voltage | I/O power supply minus voltage drop for short-circuit protection |
| Voltage drop for short-circuit protection at 0.5 A | Max. 2 VDC |
| Summation current | Max. 0.5 A |
| Short-circuit proof | Yes |
| Quantity | Up to 8, configuration as input or output using software |
| Encoder inputs | 24 V, asymmetrical |
| Counter size | 16-bit |
| Max. transfer rate | 1 Mbit/s |
| Coding | Gray/Binary |
| Overload characteristics of encoder power supply | Short-circuit proof, overload-proof |
| Transfer rate | 125 kbit/s, 250 kbit/s, 500 kbit/s, 1 Mbit/s |
| 5 VDC | Module-internal, max. 0.3 A summation current |
| 24 VDC | Module-internal, max. 0.5 A summation current |
| Input frequency | Max. 100 kHz |
| Evaluation | 2x |
| Hardware | ≤2 µs |
| Software | - |
| Common-mode range | -7 V ≤ VCM ≤ +12 V |
| Encoder power supply 24 VDC | Module-internal, max. 0.5 A summation current |
| Input characteristics per EN 61131-2 | Type 1 |
| Additional functions | Pulse width modulation, comparator function |
| Input circuit | Sink |
| Input voltage | 18 to 30 VDC |
| Input current at 24 VDC | Approx. 3.3 mA |
| Input resistance | 7.31 kΩ |
| Low | <5 VDC |
| High | >15 VDC |
| Possible measurements | Gate time, period duration, edge offset for various channels |
| Measurements per module | Up to 9 |
| Measurements per channel | Up to 2 |
| Signal form | Square wave pulse |
| Internal | 8 MHz, 4 MHz, 2 MHz, 1 MHz, 500 kHz, 250 kHz, 125 kHz, 62.5 kHz |
| Measurement type | Continuous or triggered |
| Type | 5 VDC differential signal, EiA RS485 standard |
| Output circuit | Sink or source |
| Output protection | Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads, reverse polarity protection of the output power supply |
| Variant | Push / Pull / Push-Pull |
| Diagnostic status | Output monitoring |
| Nominal output current | 0.1 A |
| Total nominal current | 0.8 A |
| Braking voltage when switching off inductive loads | Switching voltage + 0.6 VDC |
| Switch-on in the event of overload shutdown or short-circuit shutdown | Approx. 10 ms (depends on the module temperature) |
| Peak short-circuit current | <10 A |
| Leakage current when the output is switched off | Max. 25 µA |
| Residual voltage | <0.9 V at 0.1 A nominal current |
| Switching voltage | I/O power supply minus residual voltage |
| Period duration | 41.6 µs to 500 ms |
| Pulse duration | 0 to 100% |
| Resolution | 0.1% |
| Resistive load | Max. 24 kHz |
| 0 → 1 | <2 µs |
| 1 → 0 | <2 µs |
| Electrical isolation | Bus isolated from encoder and channel Channel not isolated from channel and encoder Encoder not isolated from encoder |
| Any | Yes |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP67 |
| Operation | -25 to 60°C |
| Derating | - |
| Storage | -40 to 85°C |
| Transport | -40 to 85°C |
| Width | 53 mm |
| Height | 85 mm |
| Depth | 42 mm |
| Weight | 200 g |
| M8 | Max. 0.4 Nm |
| M12 | Max. 0.6 Nm |