产品概览
| 库存情况 | 需按需确认 |
| 分类 | Counter functions |
| 生命周期状态 | active |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
发货与库存
X20DC1073 何时可以发货?
X20DC1073 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 X20DC1073 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 X20DC1073 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 X20DC1073 安排当日快递或专车加急配送。
SinCos encoder interfaceEncoder input monitoring5 VDC and GND for encoder supplyNetTime timestamp: Position timeCan be used with a SafeLOGIC controller The module is equipped with a SinCos encoder interface. The input signals are monitored. This makes it possible to detect open or shorted lines as well as encoder supply failures.SinCos encodersSinCos encoders with 1 Vss are mostly used in linear drives and systems with high-resolution optical or magnetic position measurement systems. The module can process input signals with a frequency of up to 400 kHz.NetTime timestamp for the positionIt is not just the position value that is important for highly dynamic positioning tasks, but also the exact time the position is measured. The module is equipped with a NetTime function for this that supplies a timestamp for the recorded position with microsecond accuracy.The timestamp function is based on synchronized timers. If a timestamp event occurs, the module immediately saves the current NetTime. After the respective data is transferred to the CPU, including this precise moment, the CPU can then evaluate the data using its own NetTime (or system time), if necessary.
技术规格
Specifications
| I/O module | 1x SinCos input |
| B&R ID code | 0xAEC6 |
| Status indicators | Counting direction, operating state, module status |
| Module run/error | Yes, using LED status indicator and software |
| Counting direction | Yes, using LED status indicator |
| Bus | 0.01 W |
| Internal I/O | 1.3 W |
| Additional power dissipation caused by actuators (resistive) [W] | - |
| Type of signal lines | Shielded lines must be used for all signal lines. |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| UL | cULus E115267 Industrial control equipment |
| HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| KC | Yes |
| Type | SinCos |
| Angular position resolution | 13-bit, with a signal of 1 VSS |
| Encoder monitoring | Yes |
| Max. encoder cable length | Max. 20 m, see "Calculating the maximum encoder cable length". |
| Signal transmission | Differential signals, symmetrical |
| Signal frequency | DC up to 400 kHz |
| Differential voltage | 1 VSS |
| Common-mode voltage | Max. ±10 V |
| Terminating resistor | 120 Ω |
| Output voltage | 5 V |
| Min. output voltage at 300 mA | 4.86 V |
| Load capacity | 300 mA |
| Overload-proof | Yes |
| Short-circuit proof | Yes |
| Electrical isolation | Channel isolated from bus Channel not isolated from channel |
| Horizontal | Yes |
| Vertical | Yes |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
| Horizontal mounting orientation | -25 to 60°C |
| Vertical mounting orientation | -25 to 50°C |
| Derating | See section "Derating". |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
| Operation | 5 to 95%, non-condensing |
| Note | Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately. |
| Pitch | 12.5+0.2 mm |