产品概览
| 库存情况 | 需按需确认 |
| 分类 | Temperature measurement |
| 生命周期状态 | active |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
发货与库存
X20AT6402 何时可以发货?
X20AT6402 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 X20AT6402 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 X20AT6402 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 X20AT6402 安排当日快递或专车加急配送。
6 inputs for thermocouplesFor sensor types J, K, N, S, B, RAdditional direct raw value measurementIntegrated terminal temperature compensationConfigurable filter timeConfigurable resolution The module is equipped with 6 inputs for J, K, N, S, B and R thermocouple sensors. The module has an integrated terminal temperature compensation.
技术规格
Specifications
| I/O module | 6 inputs for thermocouples |
| B&R ID code | 0x1BA9 |
| Status indicators | I/O function per channel, operating state, module status |
| Module run/error | Yes, using LED status indicator and software |
| Inputs | Yes, using LED status indicator and software |
| Bus | 0.01 W |
| Internal I/O | 0.91 W |
| Additional power dissipation caused by actuators (resistive) [W] | - |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 GcIP20, Ta (see X20 user's manual)FTZÚ 09 ATEX 0083X |
| UL | cULus E115267Industrial control equipment |
| HazLoc | cCSAus 244665Process control equipmentfor hazardous locations Class I, Division 2, Groups ABCD, T5 |
| DNV | Temperature: B (0 to 55°C)Humidity: B (up to 100%)Vibration: B (4 g)EMC: B (bridge and open deck) |
| CCS | Yes |
| LR | ENV1 |
| KR | Yes |
| ABS | Yes |
| BV | EC33BTemperature: 5 - 55°CVibration: 4 gEMC: Bridge and open deck |
| KC | Yes |
| Input | Thermocouple |
| Digital converter resolution | 16-bit |
| Filter time | Configurable between 1 ms and 66.7 ms |
| 1 channel | 80.4 ms with 50 Hz filter |
| N channels | (n + 1) x 40.2 ms with 50 Hz filter |
| Output format | INT |
| Type J: Fe-CuNi | ±0.0019%/°C |
| Type K: NiCr-Ni | ±0.0024%/°C |
| Type N: NiCrSi-NiSi | -270 to 1300°C (Rev. ≥D0) |
| Type S: PtRh10-Pt | ±0.0079%/°C |
| Type B: PtRh30-PtRh6 | ±0.0114%/°C |
| Type R: PtRh13-Pt | ±0.0074%/°C |
| Terminal temperature | -25.0 to 85.0°C or -25.00 to 85.00°C |
| Raw value | ±65.534 mV |
| Terminal temperature compensation | Internal |
| Sensor standard | EN 60584 |
| Sensor temperature | 1 LSB = 0.1°C or 0.01°C |
| Raw value output with respect to gain | 1 LSB = 1 µV or 2 µV |
| Type N (Rev. ≥D0) | ±0.0029%/°C |
| Range undershoot | 0x8001 |
| Range overshoot | 0x7FFF |
| Open circuit | 0x7FFF |
| Open inputs | 0x7FFF |
| General fault | 0x8000 |
| Conversion procedure | Sigma-delta |
| Linearization method | Internal |
| Permissible input signal | Max. ±5 V |
| Input filter | First-order low-pass filter / cutoff frequency 500 Hz |
| Gain | ±0.06% |
| Max. gain drift | ±0.01%/°C |
| Nonlinearity | ±0.001% |
| DC | >70 dB |
| 50 Hz | >70 dB |
| Common-mode range | ±15 V |
| Crosstalk between channels | <-70 dB |
| Between channel and bus | 500 Veff |
| With artificial convection | ±4°C after 10 min |
| With natural convection | ±2°C after 10 min |
| Electrical isolation | Channel isolated from busChannel not isolated from channel |
| Horizontal | Yes |
| Vertical | Yes |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
| Horizontal mounting orientation | 0 to 55°C |
| Vertical mounting orientation | 0 to 50°C |
| Derating | - |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
| Operation | 5 to 95%, non-condensing |
| Note | Order 1x terminal block X20TB12 separately.Order 1x bus module X20BM11 separately. |
| Pitch | 12.5+0.2 mm |