PUSH WIRE® connector for junction boxes; for solid and stranded conductors; max. 2.5 mm²; 6-conductor; transparent housing; violet cover; Surrounding air temperature: max 60°C; 2,50 mm²; tran
请求报价
产品概览
| 库存情况 | 需按需确认 |
| 分类 | Installation Terminal Blocks and Connectors |
| 生命周期状态 | active |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
发货与库存
773-106 何时可以发货?
773-106 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 773-106 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 773-106 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 773-106 安排当日快递或专车加急配送。
<h2>Push wire® splicing connector, 773 Series, transparent</h2><br/><br/>Seamless electrical installations are guaranteed with push wire® splicing connector (item number 773-106). The 773 Series PUSH WIRE® connectors for junction boxes provide safe, quick, and easy installations in any building, no matter the position or location. Strip lengths must be 12 mm when connecting conductors to push wire® splicing connector. Rated current and voltage are key factors to consider when choosing a splicing connector, as they determine the product's suitability for different applications. This product has a rated voltage of 400 V and a rated current of 24 A, making it suitable for high-load applications. This product incorporates conductor terminals and utilizes PUSH WIRE®. Our reliable PUSH WIRE® connection offers the fastest method for clamping conductors. It utilizes the conductor's stiffness to overcome the clamping spring's contact force. Dimensions: (18.8 x 13.1 x 19.5) mm (width x height x depth). Depending on the conductor type, push wire® splicing connector is ideal for conductor cross sections ranging from 0.75 mm² to 2.5 mm².<br/><br/><h3></h3><br/><br/>The contact surface is coated with tin.<br/>
技术规格
Notes
| General safety information | NOTICE: Observe installation and safety instructions!Only to be used by electricians!Do not work under voltage/load!Use only for proper use!Observe national regulations/standards/guidelines!Observe technical specifications for the products!Observe the number of permissible potentials!Do not use damaged/dirty components!Observe conductor types, cross-sections and strip lengths!Insert conductor until it hits the product‘s backstop!Use original accessories!To be sold only with installation instructions! |
| Safety Information | in grounded power lines |
Electrical data - Ratings per IEC/EN
| Ratings per | IEC/EN 60664-1 |
| Nominal voltage (II/2) | 400 V |
| Rated impulse withstand voltage (II/2) | 4 kV |
| Rated current | 24 A |
| Legend (ratings) | (II / 2) ≙ Overvoltage category II / Pollution degree 2 |
| Ratings per | IEC/EN 60664-1 / IEC/EN 60664-1 / IEC/EN 60664-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 400 V |
| Rated impulse withstand voltage | 4 kV |
| Rated current | 24 A |
Electrical data - General information
| Wiring direction | Side-entry wiring |
Connection data
| Clamping units | 6 |
| Total number of potentials | 1 |
Connection data - Connection 1
| Connection technology | PUSH WIRE® |
| Actuation type | Push-in |
| Connectable conductor materials | Copper, Aluminum |
| Connectable conductor materials (note) | Terminating Aluminum Conductors (not for use in North America) WAGO Spring-Clamp Terminal Blocks are also suitable for solid aluminum conductors up to 4 mm²/12 AWG if WAGO “Alu-Plus” Contact Paste 249-130 is used for termination.“Alu-Plus” Contact Paste Advantages:Automatically destroys the oxide film during clamping.Prevents fresh oxidation at the clamping point.Prevents electrolytic corrosion between aluminum and copper conductors (in the same terminal block).Provides long-term protection against corrosion.For spring pressure connections with PUSH WIRE® connection technology, WAGO recommends that the aluminum conductor first be cleaned and then immediately inserted into the clamping unit filled with “Alu-Plus” contact paste.It is also possible to apply WAGO “Alu-Plus” additionally on the whole surface of the aluminum conductor before termination.Please note that the nominal currents must be adapted to the reduced conductivity of the aluminum conductors:2.5 mm² = 16 A4 mm² = 22 A |
| Solid conductor | 0.75 … 2.5 mm² / 18 … 12 AWG |
| Stranded conductor | 1.5 … 2.5 mm² / 16 … 12 AWG |
| Note (conductor cross-section) | When using conductors of the same diameter, 0.75 mm²/18 AWG cross-section is also possible. |
| Strip length | 12 mm / 0.47 inches |
| Wiring direction | Side-entry wiring |
Physical data
| Width | 18.8 mm / 0.74 inches |
| Height | 13.1 mm / 0.516 inches |
| Depth | 19.5 mm / 0.768 inches |
Material data
| Note (material data) | Information on material specifications can be found here |
| Color | transparent |
| Cover color | violet |
| Material group | IIIa |
| Insulation material (main housing) | Polycarbonate (PC) |
| Flammability class per UL94 | V2 |
| Clamping spring material | Chrome-nickel spring steel (CrNi) |
| Contact material | Electrolytic copper (ECu) |
| Contact plating | Tin |
| Fire load | 0.076 MJ |
| Weight | 3.5 g |
Environmental requirements
| Ambient temperature (operation) | +60 °C |
| Continuous operating temperature | 105 °C |
Commercial data
| Product Group | 7 (Push Wire Conn.) |
| PU (SPU) | 500 (50) pcs |
| Packaging type | box |
| Country of origin | CN |
| GTIN | 4044918397681 |
| Customs tariff number | 85369010000 |
Product Classification
| UNSPSC | 39121409 |
| eCl@ss 10.0 | 27-14-11-04 |
| eCl@ss 9.0 | 27-14-11-04 |
| ETIM 9.0 | EC000446 |
| ETIM 10.0 | EC000446 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |