Radio Receiver EnOcean
请求报价
产品概览
| 库存情况 | 需按需确认 |
| 分类 | I/O Systems |
| 生命周期状态 | active |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
发货与库存
750-642 何时可以发货?
750-642 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 750-642 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 750-642 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 750-642 安排当日快递或专车加急配送。
<p>The 750-642 Module receives radio telegrams from maintenance-free, self-powered and wireless switches/sensors based on EnOcean radio technology.</p><p>This module can be operated with any controller within the WAGO I/O System 750. Preprogrammed function blocks make integration easy.</p><p>The energy required for switch or sensor operation is produced by converting one type of energy (heat, solar or mechanical energy) into usable electrical energy. The radiated energy from the transmitter modules is approximately one million times smaller than mobile phones. Almost any number of sensors is possible. However, the maximum number is around 100 transmitters per module due to the increasing density of switches/sensors.</p><p>Four billion code numbers provide for clear transmitter/receiver assignment. Repeated, time-shifted transmission of the radio telegrams, at very short transmission times, results in a high level of protection against external interference.</p><p>The maximum transmission range is 300 meters in open field. Depending on building materials and spatial geometry, the range may be reduced to typically 30 meters (see manual for more information). To assess the transmission path, the LED (RSSI) indicates a sufficient input level.</p><p>*Documentation available in German and English.</p><p>An SMA socket is used to connect an external antenna to the housing. The external magnetic-mount antenna (758-910) features a 2.5 m long coaxial cable and SMA plug (available as an accessory).</p>
技术规格
Notes
| Note | The maximum range in the field decreases with use in buildings and changes depending on the building materials used and the spatial geometry. Therefore, range specifications within buildings can only represent a typical value that can normally be achieved. More detailed information is available in the manual. |
Technical data
| Radio technology | EnOcean |
| Frequency band | 868.3 MHz |
| Transmission range | up to 300 m in open space (typ. in buildings, see manual) |
| Data width | 1 x 24-bit input/output (3-byte user data); 1 x 8-bit control/status |
| Supply voltage (system) | 5 VDC; via data contacts |
| Current consumption (5 V system supply) | 80 mA |
| Isolation | 500 V antenna connection/system |
Connection data
| Connection technology: antenna | 1 x SMA socket |
| Connectable conductor materials | Copper |
Physical data
| Width | 24 mm / 0.945 inches |
| Height | 100 mm / 3.937 inches |
| Depth | 72 mm / 2.835 inches |
| Depth from upper-edge of DIN-rail | 64.8 mm / 2.551 inches |
Mechanical data
| Mounting type | DIN-35 rail |
Material data
| Housing material | Polycarbonate; polyamide 6.6 |
| Fire load | 2 MJ |
| Weight | 86.5 g |
| Conformity marking | CE |
| Conformity marking RTTE | www.wago.com |
Environmental requirements
| Ambient temperature (operation) | 0 … +55 °C |
| Ambient temperature (storage) | -40 … +85 °C |
| Protection type | IP20 |
| Pollution degree | 2 per IEC 61131-2 |
| Operating altitude | 0 … 2000 m / 0 … 6562 ft |
| Mounting position | Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom |
| Relative humidity (without condensation) | 95 % |
| Vibration resistance | 4g per IEC 60068-2-6 |
| Shock resistance | 15g per IEC 60068-2-27 |
| EMC immunity to interference | per EN 61000-6-2 |
| EMC emission of interference | per EN 61000-6-3 |
| Exposure to pollutants | Per IEC 60068-2-42 and IEC 60068-2-43 |
| Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 % | 10 ppm |
| Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 % | 25 ppm |
Commercial data
| Product Group | 15 (I/O System) |
| PU (SPU) | 1 pcs |
| Packaging type | box |
| Country of origin | DE |
| GTIN | 4045454509583 |
| Customs tariff number | 85389099990 |
| End of Sale | 2023-11-01 |
| End of Production | 2024-01-31 |
| End of Delivery | 2024-02-01 |
| End of Service and Repair | 2026-02-01 |
| Support period for security updates | 2029-03-01 |
Product Classification
| UNSPSC | 32101619 |
| eCl@ss 10.0 | 27-24-26-08 |
| eCl@ss 9.0 | 27-24-26-08 |
| ETIM 9.0 | EC001604 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| CAS-No. | 12060-00-3, 1303-86-2, 1317-36-8, 25550-51-0, 7439-92-1 |
| REACH Candidate List Substance | 4-Methyl-1,2-cyclohexanedicarboxylic anhydride, Diboron trioxide, Lead, Lead monoxide, Lead titanium oxide (PbTiO3) |
| RoHS Compliance Status | Compliant,With Exemption |
| RoHS Exemption | 6(c), 7(a), 7(c)-I, 7(c)-II |
| SCIP notification number (Austria) | e197d882-ba3a-4d37-92aa-a4d309875950 |
| SCIP notification number (Belgium) | e2cbc5dd-d742-477d-a8fd-c7bbc53eff50 |
| SCIP notification number (Bulgaria) | af8dea0f-9ff8-4ad5-84a1-dfa79b6666d0 |
| SCIP notification number (Czech Republic) | 8ddc84c0-bc24-4459-b680-1cc12bc2635b |
| SCIP notification number (Denmark) | ccdb48af-5d25-49cb-b9e2-49981d49c571 |
| SCIP notification number (Finland) | 0e947340-75d5-492d-818f-5c2a8c15b74f |
| SCIP notification number (France) | 79dbd424-5276-49f6-8bfe-12e5e400631f |
| SCIP notification number (Germany) | 6733095a-a49d-49c5-86e7-45fdcd1e9ecb |
| SCIP notification number (Hungary) | 2824ae9b-d333-46cf-82f4-08348d1b9054 |
| SCIP notification number (Italy) | be85ebfe-a667-458d-9fd9-2404953f7901 |
| SCIP notification number (Netherlands) | c386c93d-fa67-441e-a954-7566a41bd18a |
| SCIP notification number (Poland) | 3e8daaa0-c8dc-448f-889f-48d89b00385c |
| SCIP notification number (Romania) | ba0e8c16-d605-48bf-933b-321d0ec0ecb6 |
| SCIP notification number (Sweden) | 9ca2569c-b095-4504-9be2-daaeafaed96a |