2-conductor through terminal block; 50 mm²; suitable for Ex e II applications; lateral marker slots; only for DIN 35 x 15 rail; POWER CAGE CLAMP; 50,00 mm²; light gray
请求报价
产品概览
| 库存情况 | 需按需确认 |
| 分类 | Rail-Mount Terminal Blocks |
| 生命周期状态 | active |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
发货与库存
285-950 何时可以发货?
285-950 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 285-950 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 285-950 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 285-950 安排当日快递或专车加急配送。
<h2>High-current terminal block, 285 Series, t-wrench und 8 mm</h2><br/><br/>Our through terminal block (item number 285-950) is designed for seamless electrical installations. Ensure that the strip lengths are 32 mm when connecting conductors to this through terminal block. This product features conductor terminals and utilizes POWER CAGE CLAMP. The POWER CAGE CLAMP is perfect for connecting large conductor cross-sections. This universal connector is both reliable and maintenance-free. What’s more, you can use it to connect all types of conductors and the clamping point can be locked open, making it easier to use. You do not need to use a torque wrench or prepare the conductor. For example, crimping ferrules is not necessary. Depending on the conductor type, this through terminal block is ideal for conductor cross sections ranging from 10 mm² to 50 mm².<br/><br/><h3></h3><br/><br/>This product is designed for specific Ex applications (please refer to the product datasheet).<br/>
技术规格
Electrical data - Ratings per IEC/EN
| Ratings per | IEC/EN 60947-7-1 |
| Ratings per | IEC/EN 60947-7-1 / IEC/EN 60947-7-1 / IEC/EN 60947-7-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
Electrical data - Ratings per UL
| Approvals per | UL 1059 |
| Rated voltage UL (Use Group B) | 600 V |
| Rated current UL (Use Group B) | 150 A |
| Rated voltage UL (Use Group C) | 600 V |
| Rated current UL (Use Group C) | 150 A |
| Approvals per | UL 1059 / UL 1059 / UL 1059 |
| Use group | B / C / D |
| Rated voltage | 600 V / 600 V |
| Rated current | 150 A / 150 A |
Electrical data - Ratings per CSA
| Approvals per | CSA 22.2 No 158 |
| Rated voltage CSA (Use Group B) | 600 V |
| Rated current CSA (Use Group B) | 150 A |
| Rated voltage CSA (Use Group D) | 600 V |
| Rated current CSA (Use Group D) | 150 A |
| Approvals per | CSA 22.2 No 158 / CSA 22.2 No 158 / CSA 22.2 No 158 |
| Use group | B / C / D |
| Rated voltage | 600 V / 600 V |
| Rated current | 150 A / 150 A |
Electrical data - Ex information
| Reference to hazardous areas | See “Downloads – Documentation – Additional Information: Technical Section; Technical Explications” |
| Ratings per | ATEX: PTB 98 ATEX 3134 U (Ex eb IIC Gb) |
| Rated voltage EN (Ex e II) | 880 V |
| Rated current (Ex e II) | 134 A |
Electrical data - Power Loss
| Power loss, per pole (potential) | 3.771 W |
| Rated current I<sub>N</sub> for power loss specification | 134 A |
| Resistance value for specified, current-dependent power loss | 0 Ω |
Electrical data - General information
| Wiring direction | Side-entry wiring |
Connection data
| Clamping units | 2 |
| Total number of potentials | 1 |
| Number of levels | 1 |
| Number of jumper slots | 2 |
Connection data - Connection 1
| Connection technology | POWER CAGE CLAMP |
| Actuation type | T-wrench; 8 mm, Operating tool |
| Connectable conductor materials | Copper |
| Nominal cross-section | 50 mm² |
| Solid conductor | 10 … 50 mm² / 8 … 1/0 AWG |
| Stranded conductor | 10 … 70 mm² / 8 … 2/0 AWG |
| Fine-stranded conductor | 10 … 70 mm² / 8 … 2/0 AWG |
| Fine-stranded conductor; with insulated ferrule | 10 … 50 mm² / 8 … 1/0 AWG |
| Fine-stranded conductor; with uninsulated ferrule | 10 … 50 mm² / 8 … 1/0 AWG |
| Strip length | 32 mm / 1.26 inches |
| Wiring direction | Side-entry wiring |
Physical data
| Width | 20 mm / 0.787 inches |
| Height | 94 mm / 3.701 inches |
| Depth from upper-edge of DIN-rail | 87 mm / 3.425 inches |
Mechanical data
| Mounting type | DIN-35 x 15 rail, DIN-rail 35 x 15; 2.3 mm thick; copper |
| Mounting (note) | only suitable for DIN 35 x 15 rail |
| Marking level | Side marking |
Material data
| Note (material data) | Information on material specifications can be found here |
| Color | light gray |
| Material group | I |
| Insulation material (main housing) | Polyamide (PA66) |
| Flammability class per UL94 | V0 |
| Fire load | 2.164 MJ |
| Weight | 158.7 g |
Environmental requirements
| Processing temperature | -35 … +85 °C |
| Continuous operating temperature | -60 … +105 °C |
Commercial data
| PU (SPU) | 5 (1) pcs |
| Packaging type | box |
| Country of origin | PL |
| GTIN | 4055143418522 |
| Customs tariff number | 85369010000 |
Product Classification
| UNSPSC | 39121410 |
| eCl@ss 10.0 | 27-14-11-20 |
| eCl@ss 9.0 | 27-14-11-20 |
| ETIM 9.0 | EC000897 |
| ETIM 10.0 | EC000897 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |