2-conductor fuse terminal block; with pivoting fuse holder; for miniature metric fuse 1/4 x 1 mm; without blown fuse indication; for DIN-rail 35 x 15 and 35 x 7.5; 4 mm²; CAGE CLAMP®; gray
请求报价
产品概览
| 库存情况 | 需按需确认 |
| 分类 | Rail-Mount Terminal Blocks |
| 生命周期状态 | active |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
发货与库存
281-613 何时可以发货?
281-613 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 281-613 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 281-613 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 281-613 安排当日快递或专车加急配送。
<h2>Fuse terminal block, 281 Series, CAGE CLAMP®</h2><br/><br/>Our fuse terminal block (item number 281-613) simplifies electrical installations. Strip lengths must be between 9 and 10 mm when connecting conductors to this fuse terminal block. Featuring conductor terminals along with CAGE CLAMP®, this connector delivers reliable performance. Our CAGE CLAMP® connection provides a secure and maintenance-free way to connect all types of conductors. You do not need to prepare the conductor in any way, such as crimping ferrules. This fuse terminal block is suitable for conductor cross sections ranging from 0.08 mm² to 4 mm².<br/><br/><h3></h3>
技术规格
Electrical data - Ratings per IEC/EN
| Ratings per | IEC/EN 60947-7-3 |
| Nominal voltage (III/3) | 800 V |
| Rated impulse withstand voltage (III / 3) | 8 kV |
| Rated current | 10 A |
| Operation status indicator | None |
| Legend (ratings) | (III / 3) ≙ Overvoltage category III / Pollution degree 3 |
| Ratings per | IEC/EN 60947-7-3 / IEC/EN 60947-7-3 / IEC/EN 60947-7-3 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 800 V |
| Rated impulse withstand voltage | 8 kV |
| Rated current | 10 A |
Electrical data - Ratings per IEC/EN – Notes
| Ratings (note) | Electrical ratings are given by the fuse. |
Electrical data - Power Loss
| Power loss (max.) P<sub>l (max.)</sub> (note) | When selecting glass cartridge fuses, make sure that the maximum power loss listed below is not exceeded. The power loss is determined according to IEC or EN 60947-7-3/VDE 0611-6 at 23°C. The temperature rise of the terminal block must be checked according to their application and mounting. Higher ambient temperatures represent an additional impact on miniature fuses. Therefore, in such applications, the rated current must be reduced if necessary. More details are available from the manufacturers. |
| Maximum power loss P<sub>loss</sub> of fuse insert for overload and short-circuit protection (individual arrangement) | 2.5 W |
| Maximum power loss P<sub>loss</sub> of fuse insert for overload and short-circuit protection (block arrangement) | 1.6 W |
| Power loss P<sub>l</sub> max. short-circuit protection (individual arrangement) | 4 W |
| Power loss P<sub>loss</sub> (max.) of fuse cartridge for short-circuit protection (block arrangement) | 4 W |
Electrical data - General information
| Fuse receptacle | pivoting |
| Fuse type | Cylindrical fuse; ¼" x 1" |
| Wiring direction | Front-entry wiring |
Connection data
| Clamping units | 2 |
| Total number of potentials | 2 |
| Number of levels | 1 |
Connection data - Connection 1
| Connection technology | CAGE CLAMP® |
| Actuation type | Operating tool |
| Connectable conductor materials | Copper, Aluminum |
| Connectable conductor materials (note) | Terminating Aluminum ConductorsWAGO Spring-Clamp Terminal Blocks are suitable for solid aluminum conductors up to 4 mm²/12 AWG if WAGO “Alu-Plus” Contact Paste 249-130 is used for termination.“Alu-Plus” Contact Paste Advantages:Automatically destroys the oxide film during clamping.Prevents fresh oxidation at the clamping point.Prevents electrolytic corrosion between aluminum and copper conductors (in the same terminal block).Provides long-term protection against corrosion.Using terminal blocks with CAGE CLAMP® Spring Pressure Connection Technology, aluminum conductors must first be cleaned with a blade and then immediately inserted into the clamping units filled with “Alu-Plus” contact paste.It is also possible to apply WAGO “Alu-Plus” additionally on the whole surface of the aluminum conductor before termination.Please note that the nominal currents must be adapted to the reduced conductivity of the aluminum conductors:2.5 mm² = 16 A4 mm² = 22 A |
| Solid conductor | 0.08 … 4 mm² / 28 … 12 AWG |
| Fine-stranded conductor | 0.08 … 4 mm² / 28 … 12 AWG |
| Strip length | 9 … 10 mm / 0.35 … 0.39 inches |
| Wiring direction | Front-entry wiring |
Physical data
| Width | 10 mm / 0.394 inches |
| Height | 60 mm / 2.362 inches |
| Depth from upper-edge of DIN-rail | 60 mm / 2.362 inches |
Mechanical data
| Design | angled |
| Mounting type | DIN-35 rail |
| Marking level | Center marking |
Material data
| Note (material data) | Information on material specifications can be found here |
| Color | gray |
| Material group | I |
| Insulation material (main housing) | Polyamide (PA66) |
| Flammability class per UL94 | V0 |
| Fire load | 0.376 MJ |
| Weight | 19.6 g |
Environmental requirements
| Processing temperature | -35 … +85 °C |
| Continuous operating temperature | -60 … +105 °C |
Commercial data
| Product Group | 1 (Rail Mounted Terminal Blocks) |
| PU (SPU) | 50 pcs |
| Packaging type | box |
| Country of origin | CN |
| GTIN | 4045454871499 |
| Customs tariff number | 85369095000 |
Product Classification
| UNSPSC | 39121410 |
| eCl@ss 10.0 | 27-14-11-16 |
| eCl@ss 9.0 | 27-14-11-16 |
| ETIM 9.0 | EC000899 |
| ETIM 10.0 | EC000899 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |