可按需提供

Double-deck terminal block; Shield/through terminal block; 2.5 mm²; Shielding/N; with marker carrier; Blue conductor entry upper deck; for DIN-rail 35 x 15 and 35 x 7.5; Push-in CAGE CLAMP®;

制造商料号: 2002-2248 · 品牌: Wago
价格面议
请求报价

工作人员将亲自回复,通常在1个工作日内——详见我们的 隐私政策.

12个月保修(全新)· 3个月(二手/翻新)
30天退货,未使用零部件退货免收上架费
发货方式

产品概览

库存情况需按需确认
分类Rail-Mount Terminal Blocks
生命周期状态active
保修12个月(全新)· 3个月(二手/翻新)

发货与库存

2002-2248 何时可以发货?

2002-2248 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。

可以亲自到店提取 2002-2248 吗?

可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。

是否提供快递服务?

可以——在为 2002-2248 申请报价时告诉我们,我们会在回复中附上快递发货选项。

我们的工厂停产了,急需这个零部件——你们能帮忙吗?

如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 2002-2248 安排当日快递或专车加急配送。

<h2>Double-deck terminal block, 2002 Series, operating tool</h2><br/><br/>Enjoy easy electrical installations with this double-deck terminal block (item number 2002-2248). Strip lengths must be between 10 and 12 mm  when connecting conductors to this double-deck terminal block. The double-deck terminal block also functions as a shield terminal block as well as a through terminal block. Featuring conductor terminals along with Push-in CAGE CLAMP®, this connector outperforms the competition. Our Push-in CAGE CLAMP® is a universal, maintenance-free connection solution for all conductor types, featuring a winning design: It allows direct insertion of both solid and fine-stranded conductors with ferrules without needing tools. No preparation is required; for example, crimping the conductor's ferrule is not necessary. Depending on the type of conductor, this double-deck terminal block is ideal for conductor cross sections ranging from 0.25 mm² to 4 mm².<br/><br/><h3></h3>

技术规格

Electrical data - Ratings per IEC/EN

Ratings perIEC/EN 60947-7-1
Nominal voltage (III/3)500 V
Rated impulse withstand voltage (III / 3)6 kV
Rated current24 A
Current at conductor cross-section (max.) mm²28 A
Legend (ratings)(III / 3) ≙ Overvoltage category III / Pollution degree 3
Ratings perIEC/EN 60947-7-1 / IEC/EN 60947-7-1 / IEC/EN 60947-7-1
Overvoltage categoryIII / III / II
Pollution degree3 / 2 / 2
Nominal voltage500 V
Rated impulse withstand voltage6 kV
Rated current24 A
Current at conductor cross-section (max.) mm²28 A

Electrical data - Ratings per UL

Approvals perUL 1059
Rated voltage UL (Use Group B)300 V
Rated current UL (Use Group B)20 A
Rated voltage UL (Use Group C)300 V
Rated current UL (Use Group C)20 A
Rated voltage UL (Use Group D)600 V
Rated current UL (Use Group D)5 A
Approvals perUL 1059 / UL 1059 / UL 1059
Use groupB / C / D
Rated voltage300 V / 300 V / 600 V
Rated current20 A / 20 A / 5 A

Electrical data - Ratings per CSA

Approvals perCSA 22.2 No 158
Rated voltage CSA (Use Group B)300 V
Rated current CSA (Use Group B)20 A
Rated voltage CSA (Use Group C)300 V
Rated current CSA (Use Group C)20 A
Approvals perCSA 22.2 No 158 / CSA 22.2 No 158 / CSA 22.2 No 158
Use groupB / C / D
Rated voltage300 V / 300 V
Rated current20 A / 20 A

Electrical data - Ex information

Ratings perATEX: PTB 03 ATEX 1162 U / IECEx: PTB 03.0004U (Ex eb IIC Gb)
Rated voltage EN (Ex e II)440 V
Rated current (Ex e II)20 A
Rated current (Ex e II) with jumper18 A

Electrical data - Power Loss

Power loss, per pole (potential)0.766 W
Rated current I<sub>N</sub> for power loss specification24 A
Resistance value for specified, current-dependent power loss0.001 Ω

Electrical data - General information

Wiring directionFront-entry wiring

Connection data

Clamping units4
Total number of potentials2
Number of levels2
Number of jumper slots4

Connection data - Connection 1

Connection technologyPush-in CAGE CLAMP®
Number of connection points2
Actuation typeOperating tool
Connectable conductor materialsCopper
Nominal cross-section2.5 mm²
Solid conductor0.25 … 4 mm² / 22 … 12 AWG
Solid conductor; push-in termination0.75 … 4 mm² / 18 … 12 AWG
Fine-stranded conductor0.25 … 4 mm² / 22 … 12 AWG
Fine-stranded conductor; with insulated ferrule0.25 … 2.5 mm² / 22 … 14 AWG
Fine-stranded conductor; with ferrule; push-in termination1 … 2.5 mm² / 18 … 14 AWG
Note (conductor cross-section)Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
Strip length10 … 12 mm / 0.39 … 0.47 inches
Wiring directionFront-entry wiring

Connection data - Connection 2

Number of connection points2

Physical data

Width5.2 mm / 0.205 inches
Height69.7 mm / 2.744 inches
Depth from upper-edge of DIN-rail61.8 mm / 2.433 inches

Mechanical data

Potential markingShield/N
Mounting typeDIN-35 rail
Marking levelCenter/side marking

Material data

Note (material data)Information on material specifications can be found here
Colorgray
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.212 MJ
Weight13.4 g

Environmental requirements

Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C

Environmental requirements - Environmental Testing

Test specification: <br/>Railway applications –<br/>Rolling stock –<br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure: <br/>Railway applications – <br/>Rolling stock equipment – <br/>Vibration and shock testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Mounting locationService life test, Category 1, Class A/B
Functional test with noise-like oscillationsTest passed according to Section 8 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.101g (highest test level used for all axes)
Test duration per axis10 min.
Test directionsX, Y and Z axes
Monitoring of contact faults and interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like oscillationsTest passed according to Section 9 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.572g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock pulse formHalf sine
Acceleration5g (highest test level used for all axes)
Shock duration30 ms
Number of shocks (per axis)3 pos. und 3 neg.
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Vibration and shock stress for rolling stock equipmentPassed

Commercial data

Product Group22 (TOPJOB S)
PU (SPU)50 pcs
Packaging typebox
Country of originDE
GTIN4050821175179
Customs tariff number85369010000

Product Classification

UNSPSC39121410
eCl@ss 10.027-14-11-41
eCl@ss 9.027-14-11-41
ETIM 9.0EC000901
ETIM 10.0EC000901
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption
12个月保修适用于所有全新库存
3个月保修适用于二手及翻新零部件
30天退货未使用零部件退货免收上架费
全球发货全球快速可追踪配送

更多 Wago 产品

Wago - 8MCS二手Wago - 8MCS
制造商料号: 8MCS · Wago
€5.30
查看详情
Wago - 4MCS二手Wago - 4MCS
制造商料号: 4MCS · Wago
€5.30
查看详情
Wago AW6 26-14二手Wago AW6 26-14
制造商料号: AW6 26-14 · Wago
€5.30
查看详情
WAGO 750-602 Used二手WAGO 750-602 Used
制造商料号: 750-602 · Wago
€10.60
查看详情