Sick Commissioning Lector
请求报价
产品概览
| 库存情况 | 需按需确认 |
| 分类 | Installation and commissioning |
| 生命周期状态 | active |
| 保修 | 12个月(全新)· 3个月(二手/翻新) |
发货与库存
Commissioning Lector 何时可以发货?
Commissioning Lector 属于按需采购产品——请申请报价,我们会为这一具体单品确认准确的库存情况及发货时间。
可以亲自到店提取 Commissioning Lector 吗?
可以在我们位于荷兰格罗宁根的仓库安排自提——请在下单前联系我们,确认库存情况并预约提货时间。
是否提供快递服务?
可以——在为 Commissioning Lector 申请报价时告诉我们,我们会在回复中附上快递发货选项。
我们的工厂停产了,急需这个零部件——你们能帮忙吗?
如遇紧急故障,请直接致电 +31 (0)50-7110348 或发邮件至 sales@partnerplc.com 联系我们——我们可根据库存情况及目的地,为 Commissioning Lector 安排当日快递或专车加急配送。
Engineering and integration | Installation and commissioning | Commissioning Lector | Product area: Image-based code readers | Range of services: Inspection of connection, fine adjustment, optimization of parameters of SICK product as well as testsSet-up of previously defined functions of possible illumination, code configuration, trigger and digital inputs, interfaces and digital outputs as well as data processing | Documentation: Archiving of product parameters in a SICK databaseDocumentation of reading performanceCreation of a commissioning log | Duration: Additional work will be invoiced separately
技术规格
Features
| Product version | Ident commissioning |
| Product area | Image-based code readers |
| Prerequisites | Feasibility analysis, taking into account the specifications for the SICK productDefinition of the required functionsSICK product is mounted, electrically connected, and connected to the plantSICK product is configured with factory settingsSupply voltage and host connection are available at the installation siteSICK product and programming interface are easily accessible without toolsProvision of test objects and barcodes as referenceAvailability of the plant for the duration of the service |
| Range of services, brief | Inspection of connection, fine adjustment, optimization of parameters of SICK product as well as testsSet-up of previously defined functions of possible illumination, code configuration, trigger and digital inputs, interfaces and digital outputs as well as data processing |
| Range of services | Preliminary analysis of possible influences of ambient conditionsInspection and possible correction of wiring and connection of the SICK productAlignment and fine adjustment of the SICK productSetting of application-specific parameters, e.g. possible illumination, code configuration, trigger and digital inputs, interfaces and digital outputs, data processingFunction and communication testIterative process within the estimated work time in order to optimize the reading performance for the applicationInspection of static or dynamic reading performanceTests on the sensor interface for the machine or plant with test objects and barcodes provided by the customerBasic training for employees to explain how to operate the SICK product correctlyArchiving of product parameters in a SICK database |
| Documentation | Archiving of product parameters in a SICK databaseDocumentation of reading performanceCreation of a commissioning log |
| Duration | Additional work will be invoiced separately |
| Note | Interventions in the software and controller of the overall system or the plant are not includedMechanical mounting of the SICK product must be carried out by the customer beforehand. The customer must provide qualified personnel to carry out any necessary changes to the mounting arrangements.Small parts are not included in the range of services |
| Machine life cycle | InstallationCommissioning |
Classifications
| ECLASS 5.0 | 25219090 |
| ECLASS 6.0 | 25219090 |
| ECLASS 6.2 | 25219090 |
| ECLASS 7.0 | 25219090 |
| ECLASS 8.0 | 25219090 |
| ECLASS 8.1 | 25219090 |
| ECLASS 9.0 | 25219090 |
| ECLASS 10.0 | 25219090 |
| ECLASS 11.0 | 25219090 |
| ECLASS 12.0 | 25219090 |
| ETIM 5.0 | --- |
| ETIM 6.0 | EC003015 |
| ETIM 7.0 | EC003015 |
| ETIM 8.0 | EC003015 |



